PRODUCT TECHNOLOGY
Normal pressure sheet
Operating principle
General pressure table
Estimated element retroversion: The measured pressure results in elastic transformation of the elastic sensitive element, the shape variable corresponds to the pressure, the pressure value is indicated on the ticboard by conversion of the mechanical motion magnification unit to the pointer angle. Sensitive elements are boden tubes - a flexible metal tube with an elliptical (or flat-sided) transect, bent to C (low pressure commonly used), a spring or a spiral (high pressure/large process), one end fixed to the neck (fixed end), and the other to be closed (free end): clarinets, the spiral tube form is equivalent to "longer" C-shaped tubes, with a larger, more sensitive, free end, for a large range of courses or for increased accuracy. (a) Bit-pressure relations: the free end is usually only 2 ~ 5 mm, with a magnified pointer approximately 270° (the standard angle of the ticboard);
- 01
The detected medium is connected to the internal cavity of the Boden tube and the pressure works on the inner side of the tube;
- 02
The ellipse is becoming a rounded cross under pressure, generating a cycling effect from the tube wall;
- 03
(b) The revolving force reduces the radians of the C tube, stretches the tube outward, and produces a free end shift due to the static end;
- 04
Free end-to-end transport is similar to the linear relationship of pressure (low-pressure range), which is amplified by pull-up core (span-centre gear) (magnification is about dozens to hundreds of times greater) and drives the pointer rotates;
Structure
General pressure table
40, 50, Q60, 75, 100, 150, 200, 250, corresponding model Y-40 ~ Y-250; Basic type Y (general pressure table), derived type YA (smud), YO (oxygen, oil ban), YQ (hydrogen), YC (magnetic aided connection point), YX (electrical link point), YZ (pressure vacuum table) etc.
- 01
· Copper alloy HPb59-1 (conventional), connected to process pipes/equipment, M10x1 / M14x1.5 / M20x1.5, etc.
- 02
Precise tubes (Boden tubes) QSn4-0.3 (conventional), stainless steel/alloy steel (high pressure); Type C/clarine/snail type
- 03
Pull the pole. Move the bodence free end to the core.
- 04
Core (move magnification) • Fan gear + centre gear + silk, transpose line zoom to angular shift, copper alloy manufacture
Application area
General pressure table . Application area
Purpose positioning: In situ pressure monitoring and manual inspection of constant temperature pressure to high pressure, clean medium, and non-corrosive, are "intro-configuration" for pressure measurements. Not applicable: CSC/HK media (reformation of diaphragm pressure table), direct contact of high temperature media (coin/screw or retrovert), FLC protection (replacement of blastproofing point table or pressure transmitter), long transmission and automatic control (reformation of pressure transmitter), high accuracy verification (refining precision pressure sheet/digital pressureometer).
- 01
Oil/chemicals • In-situ monitoring of generally less corrosive pressures such as pump exports, pipelines, tanks, heat exchangers, etc.
- 02
Electricity boiler packs, water supply, steam pipe pressure monitoring (vapour measurement and rainbow straw)
- 03
Metallurgy/mechanical Hydraulic systems, aerodynamic systems, air presses, cylinder pressure instructions
- 04
Water/heat supply Water pumps, piped networks, heat exchange stations, boiler room stress monitoring
Selection Guide
General pressure table . Selection guide
Example: Common pressure 0.6 MPa stabilization medium ⁇ Select 0~1.0 MPa Quantities (0.6 ⁇ 60% full range, compliance); The pulse is 0~1.6 MPa. Example: Y-100 = general pressure table, ⁇ 100 radium, sideless, 1.6 grade, M20 x 1.5; Y-100ZT = back of the axis belt (disk);
- 01
The three principles of the scale range shall be implemented (stabilization 2/3, pulse 1/2, high pressure 3/5, lower limit 1/3), with small error in the mass range being magnified and over-range damage to the elastic component being selected at the small scale;
- 02
Accuracy matching: the maximum indicative error of the selected grade should be less than the maximum absolute error allowed by the process, and not as high as possible (a marked increase in price per increase of one level);
- 03
Inspection management: Pressure sheets are mandatory calibration devices (safe protection) and are generally not more than 1 years, and security surveillance priority areas are usually performed on 6 monthly basis;
- 04
Installation specifications: vertical installation, station and metering intervalves to allow for validation and replacement; steam and high temperature media to add rainbow straws (U-shaped condensers) to prevent high temperature direct impact on the waved tubes;
Normal pressure sheet selection support
Provide survey missions, media and installation conditions and obtain product configuration advice.
Contact us