PRODUCT TECHNOLOGY
Switch input, relay output fence-SA6120
Operating principle
Switch input, relay output fence-SA6120 .
Switch input, relay output barrier SA6120 works around the three links "NAMUR distribution and signal detection on the side of the scene isolated transformation control relay feed". This section is based on the three angles of "Standing control inside the fence" and concludes with four key calculations of the project "NamUR standard determination + 8 V/ 8mA distribution principles + the end-of-life curve of relays + failure diagnosis and power failure safety". The site side consists of two tasks of the essence: the NAMUR distribution and signal detection. NAMUR distribution follows IEC 60947 - 5 - 6 Standard - 1 8 V voltage distribution: typical open-circuit voltage 8 V DC, by internal fence DC
- 01
2 Internal fence: DC/DC floating + Isolation transformer + MMU logic fence is composed of four parts: 1 DC/DC floating power source - 24 V-Float 8 V-output power supply,
- 02
Self-recovered) to transfer side energy/sign to control side, quarantined and resistant.
- 03
Accomplishing Ben-Ancade; thorium
- 04
③ 1500
Structure
Switch input, relay output fence-SA6120 Structure
Switch input, relay output barrier SA6120 consists of "Physical Layer 10 Component + Software Layer 10 Module".
- 01
1. Shell · PA66 Flame Retardation / DIN 35 mm track = mechanical strength + flame retardation UL94-V0
- 02
2. Connector Power + On-site + Control side relays (b) Colour coding distinction; 2.5 mm² screwdriver...
- 03
3. DC/DC floating power 24 V floating ground 8 V floating side working power
- 04
4. NAMUR distribution circuit 8V/8mA Flow-restrictive + signal detection integration
Application area
Switch input, relay output fence-SA6120 . Field of application
Switch input, relay output fences, by industry distribution, generally present " petrochemical 30% + gas 25% + chemical 20% + electricity 10% + pharmaceutical/food 10% + other 5% " . Petrochemicals and hydrocarbons are the "two main battles" with the former focusing on the response valve limit plus ESD emergency cuts, and the latter on the long pipeline valve plus tank fluid switch; (a) The chemical industry ' s high level of consistency with the NAMUR standard;
- 01
Refining Reaction Valve limit . NamUR Approach Switch (Top/Top Feedback) . Namur Distribution + Relay Output + Deactivation Security
- 02
ESD Emergency Cut-Off Valve . Spring Retort Repository Repository Limit . SIL3 + Power loss safety + trouble diagnosis .
- 03
Tank-based fluid-bit switch . Acoustic fork/ Float/ Radar-Line-bit switch . NAMUR distribution + relay output + blast-proof
- 04
Power plant boiler for flow switches · Target / Piston flow switches · Namur distribution + failure diagnosis + long cable +
Selection Guide
Switch input, relay output fence-SA6120 .
Combining the switch input, the relay output fence-SA6120 technical information, identifying the configuration by medium, measuring mission and installation environment. The complete description shows the relevant technical sections.

Switch input, relay output fence-SA6120 option support
Provide survey missions, media and installation conditions and obtain product configuration advice.
Contact us
