PRODUCT TECHNOLOGY

Super-Big Screen Monitor

Operating principle

Super-screen monitor.

(a) Core structure with "Multi-tempo input + scale transformation + large-digit remote reading display + ultra-restrictive hint": input channel collection of analogue/pulse/ temperature or communication data, after a modulation (magnifying telecommunications to project volume: tons, metres, cubic degrees Celsius), with a high power LED-driven circuit lighted above-high digital tube or point-forming group; (a) Extrapolation of output sound light tips; The communications interface supports remote re-profiling and grouping. Three unique design problems brought about by "big" — the matching of distance from remote reading with high text, the driving and power consumption of large LED arrays, and the brightness and protection of the outdoor environment — are the focus of this theoretical analysis.

  1. 01

    1 Multi-signalling input channel · Simulation: 4-20mA precision sampling resistance + differential magnification; Pulse: a MV signal is dedicated to magnification or flow pulse high-speed count; Temperature: Pt100 Three-line / Thermal Episode cold end compensation; Communications: RS-485 takes a direct indication from the main station (DCS / PLC / Qualitative)

  2. 02

    2 Parithmic variations . Any map (decimal point position, multiplier, decomposition); non-linear input (thermal electromechanical / differential) software correction; or heavyweight type containing labeling and decoiling logic

  3. 03

    3 . Extracomparison . Up- and down-limits stand-alone values and deviations; alert output relay + screen flash; alarm setting is done by remote control or communication (not enough for large screen height)

  4. 04

    4 LED Drive Circuit . Dynamic scan (timelighting) is the main: saved drive, run power consumption; scan frequency above human eye blinking threshold (> 100 Hz); multiple LEDs per section of super-high-light digital tube, constant-drive guaranteed brightness not evenly drifting with brightness decline

Super-wide monitor selection support

Provide survey missions, media and installation conditions and obtain product configuration advice.

Contact us
Super-screen monitor . Technical Note

TECHNOLOGY & APPLICATION

Understand the principles, the exact selection.

From measurement principles to field applications, the technical features and selection features of the super-large screen monitor are understood.

01

TECHNICAL GUIDE

Overview

(Big screen monitors, workshop screens, remote reading monitors) are display terminals with "long-range large-number readings" as a core function. It accepts secondary signals such as process signals (4-20mA / 1-5V), pulses, heat resistance/thermal electromechanical dolls, weighing/flow/place transfer, and RS-485 communication data, displayed in hyper-high (100 ~400 mm) LED numbers or dots after a change in the scale, and can be rotated with a voice alarm exceeding the limit and multiple parameters. The essence of "super-large" is to extend reading distance from 1-2 m to 10-50 m from conventional pallet: the workshop driver reads the stairwell at high altitude, the pump station duty duty is reading fluids across the factory, the field movement distance readings and output, the clock and production panels at the entrance to the stadium and the factory area, where "the person cannot see nearer" is the position of the super-screen monitor. It does not carry the record, control and complex alerting process, but only makes one thing extremely extreme: to give a glimpse of the numbers from a distance.

1.1 Comparison with disk-mounted monitors, wall-mounted thermometers, LED fusion screens

1.2 A brief history of development

Overview * Project / AnnotationsCross-reference
ItemAnnotations
Product positioningRemote reading display terminals: multiple signal input + scale transformation + super-high display (optional alert and group network); (a) "Way reading" positions, such as inter-car walls, plant pillars, pumping stations, and ground towers, which are an extension of the spatial dimension of the disk load monitor (reading distance 1-2 m); Distinguishing from wall-mounted thermometer (part 60): this machine is not limited to temperature, does not emphasize rapid response, emphasizes word height and telereading, and input types are covered
Core valuesHyper-referral reading distance (word height 100 ~ 400 mm, 10 ~50 m) full coverage of input signals (simulation / pulse / temperature / communication); freedom of change of scale (project volume straight, e.g. tons, metres, cubic metres); high-light outdoor readability; multi-parameter rotation display of one screen
Input FormSimulation: 4-20mA / 1-5V / 0-10mA; Pulse: a hyphen (mV) amplified, flow pulse, encoder; Temperature: Pt100 / Thermal electromechanical doll (thermal change of the large screen); Communications: RS-485 (Modbus-RTU, multi-site data aggregation)
Output FormExtra-relay relays (optional); RS-485 Communications (grouping network / remote re-show); some of the belts simulated transmissions
Market patternsThe National Production Displayer Screen Series (often accompanied by a heavy/liquid level/flow secondary table); single station 1500-20000 (high and protective class determines price differentials); and stable demand for metallurgy, mines, water, cement, logistics weight matching
Contrast DimensionsSuper-Big Screen Monitor (This Part)DIGITAL FILLS ON DIGITAL DIGITAL FILLSWall-mounted thermometer (Page 60)LED Spellscreen
Distance of reading10-50 meters1~2 metres5-10 metersDozens of meters (full screen display)
High100~400mm14~30mm40~100mmScrolling, any big
Input signalSimulate / Pulse / Temperature / Communication Full CoverSame Left (Disk)Temperature Class OnlyVideo / Network Signal
Display readingsThe value is the main + unit/ bitValue + unitsTemperature ValueAny image video
Unit price1500-20000 yuan500-2,000 CNY.300 ~ 1,500 CNY.Tens of thousands of CNY.
Work10~150W (by dimension)≤ 5W≤ 3WHundreds of W to kW
Typical applicationsWorkshop / Pump station / Field readingControl room paneStorage / Machine Room On-the-WideMovement Control Centre / Showdown Lobby
Overview · Period / StageCross-reference
PeriodPhaseTechnical characteristics
Traditional timesOverturning Cards and Large Word Mechanical DisplayMechanical roll-over (station / plant clock production); electromagnetic counter large print display; light bulb group view panel (relay logic light); small information, high maintenance
1980 ~ 90 AgeLED Digital ScreenHighlight LED digital tube is high; weighing / the knbron industry is the first to match (high-altitude reading demand); dynamic scanning drives maturity; scale transformation is by hardware dialing
2000sMulti-Commerce Smart ScreenMPU conversion: Any scale variation and project volume straight-up; simulation / pulse / temperature input full-cover; RS-485 group network and remote re-demonstration; multi-parameter rotation display
2010 to dateOutdoor highlight and dot mixSuper-high LED (readable in outdoor sunlight); digital + dot-column screen (value + HK/ bits; wireless re-spect and mix with cloud viewers; field / water / mass matching of smart sites
02

MEASUREMENT PRINCIPLE

Operating principle

(a) Core structure with "Multi-tempo input + scale transformation + large-digit remote reading display + ultra-restrictive hint": input channel collection of analogue/pulse/ temperature or communication data, after a modulation (magnifying telecommunications to project volume: tons, metres, cubic degrees Celsius), with a high power LED-driven circuit lighted above-high digital tube or point-forming group; (a) Extrapolation of output sound light tips; The communications interface supports remote re-profiling and grouping. Three unique design problems brought about by "big" — the matching of distance from remote reading with high text, the driving and power consumption of large LED arrays, and the brightness and protection of the outdoor environment — are the focus of this theoretical analysis.

2.1 Seven-large subsystems of the signal chain

2.2 Analysis of Key Rationales

Modus operandi . Serial number / subsystemCross-reference
Serial numberSubsystemFunctions and elements of achievement
1Multiple signal input channelSimulation: 4-20mA precision sample resistance + differential amplification; Pulse: a MV signal is dedicated to magnification or flow pulse high-speed count; Temperature: Pt100 Three-line / Thermal Episode cold end compensation; Communications: RS-485 takes a direct indication from the main station (DCS / PLC / Qualitative)
2Scale ChangeEnter any map of the signal to the project volume (decimal point position, multiplier, decomposition); non-linear input (thermal voltage / pressure-side) software correction; or heavyweight type containing labeling and decoiling logic
3ExtracomparisonUpper- and lower-limit independent fixed values and back-up; alarm output relay + screen flash; alarm set by remote control or communication (not enough to fit high on screen)
4LED Drive CircuitDynamic scanning (timelights) is the mainstream: save drive, control power consumption; scan frequency above human eye blinking threshold (> 100Hz); multiple LEDs per section of ultra-high-light digital tube, constant-drive guaranteed brightness not evenly drifting with brightness
5Display unitSuper-high LED digital tube (high 100 ~ 400 mm, word / double column multiple); point array group (16 x 16 ng bits/ unit / hint); mixed screen = digital visible value + point-form text
6Brightness and adaptationIndoor brightness of thousands of mcd class; outdoor ultra-high-light tube core + solar-readable design; some machine-type light-sensitive automatic lighting (night dizziness)
7Communications and remote re-enactmentRS-485 (Modbus-RTU): Receive display data from main station (blank display terminals); remotely modify fixed values / rotational parameters; and re-discover (shop inter-plant free of wiring)
· Analysis item / Mechanism descriptionCross-reference
Analysis ItemScheduling
A piece of paper with a high and remote reading distance.Engineering experience: Identifiable reading distance of approximately 100 to 200 times the word height (simple upper limit for numerical content and lower limit for complex content); 100 mm high, roughly 10~20m, 200mm roughly 20~40m, 400mm approximately 40~80m; The selection is first measured at the farthest possible distance, then the screen is pushed up, "Nine, not small" -- the cost of filling is much higher than the initials.
• Dynamic scanning and human eye vision/ large screen LED segments are numerous and the number of static-driven connections is unacceptable; (a) The dynamic scan time is lighted: the scanning frequency must be higher than the critical integration frequency (approximately 50~60Hz), and the project takes > 100Hz guaranteed no scintillation; Scan to space ratio determines average brightness - the shorter each light time the more digits, the greater the instant current (heavy-driven) compensationCross-reference
Dynamic scan and eye vision(a) Large screen LED segments are numerous and the number of static-driven connections by segment is unacceptable; (a) The dynamic scan time is lighted: the scanning frequency must be higher than the critical integration frequency (approximately 50~60Hz), and the project takes > 100Hz guaranteed no scintillation; Scan to space ratio determines average brightness - the shorter each light time the more digits, the greater the instant current (heavy-driven) compensation
Super Highlight and Open Read(a) Ten thousand luxes of direct outdoor sunlight, and "unvisible" for less bright screens; (a) The outdoors are enhanced by using ultra-high-light tube cores (single tens of thousands ~ mcd) and colour masks (high contrast); Wide-looking design ensures that it is read from a remote angle; Nights are dazzling, light-sensitive, automatic dotting is a watershed experience.
The power of large sizes and the heat of heat.400 mm high digital tube integrator power can be used 100-150W; power and drive must be designed for brightness and 30% abundance; outdoor closed-box solar irradiation superheat is superimposed, heat dispersion (natural convection/ wind cooling) and LED temperature control directly determines life
Remotely controlled grouping necessityThe screen is installed at a high location (bars/ towers/ plant pillars) and cannot be filled with panels; the parameter configuration (scale / fixed value / rotation) is fully operated by infrared remote control or RS-485; remote control interface and `all-purpose ' watch-based operation logic design are essential for ease of use
Multi-parameter rotation mechanism(a) Multiple parameters (e.g., pump fluid level 1 ~ 4) are shown on the screen on a rotating basis; Stays 5~30s in a group for each parameter; Parameter numbers are specified by small word hints for dots or end bits; (a) "The re-opening screen" and "the multi-parameter type of the same screen" (high price); The key security parameters do not recommend rotation (may happen to be visible)
03

PRODUCT STRUCTURE

Product structure

The whole machine consists of a display panel (digital/ point-formula group) + drive control panel + power source + structural units, which are built in open aluminium frame or thin box form, and an outdoor closed waterproof tank (ex-light-exceeding and dissipation) with four types of wall-mounted, hanger, pole-capped and embedded walls.

Analysis of strengths and weaknesses

4.1 Advantages

4.2 Disadvantages and responses

Show Panel

Composition and function: Super-high LED digital tube array (word height 100/ 200/ 300/ 400mm specification); optional node bar (Handels/ Unit/ Alert alert); dark panel + transparent mask (relationship and dust protection)

Driver Control

Composition and function: MPU landmark transformation and scanning control; constant flow drive chips (soft-wielding and life); scan frequency > 100Hz no scintillation; group parameter EEPROM (decharge maintenance)

Input interface panel

Composition and function: Simulation of the mass end (4-20mA / 1-5V); pulse / weight end; temperature input (variation); RS-485 end (communication with main station)

Power unit

Composition and function: 220VAC power is the main power source (high power switch); overall power consumption 10~150 W by word and by bit; wide-temperature power and mine-proof modules outdoors

Alert Output (optional)

Composition and function: upper- and lower-limit relay interface (3A / 250VAC); screen flash + external sound tower endpoint

Structures and Installations

Composition and function: indoor: aluminium frame / thin box (walled / hanging); outdoor: closed waterproof tank IP65 (stiplined/embedded wall); suspension load weight and crashproof design (scrambled environment)

Remote Controls and Grouping

Composition and function: Infrared remote control (fixed value / scale / round ionization); panel key lock (in error prevention); RS-485 remote grouping (high-range no-crawling)

Heat dispersion and protection

Composition and function: natural internal convection; outdoor closure + back wall heat/wind cooling; LED temperature control (decision item for life and light decay); mine protection and site location (thick-fire risk)

Evolutional trends

Structure: Description Composition and function:

Digital + dot-form mix screen

Structure units: Numerical (digital)+ HDR units (point array) on the same screen; information density and remote reading; traditional practice of replacing "paper labels on screen" composition and function:

Communications insularity

Structure units: Large screens are degraded to a pure display terminal: RS-485 takes the number directly from DCS / PLC; scale changes move up to the main station; field zero, content with the free definition of the host station software

Wireless and cloud-based viewers

Structure units: Wireless re-diving (cross-site free-wiring); 4G / Ethernet access to cloud platforms; co-source with LED/ mobile phone end panel data; composition and function:

Low-utility and light-deficit management

Structure units: efficient LED tube cores and smart-motion downtime; light-sensitivity automatic lighting (night-time dizziness-proofing); brightness reduction compensation and life-long awakening (high cost of large-screen switchers) Composition and function:

A long distance.

Note: 100 ~ 400 mm, 10 ~ 50 m is visible; motorists are high, movement across the plant, inspection of the cross-material field — readings are not available at a single point.

Enter signal overwrite

Description: Simulation / pulse / temperature / communications type four input; lb, liquid, flow, material, production one screen; same hardware platform modified by input card, engineering flexible

Project volume visible

Note: Scale changes to free grouping: tons, metres, cubic metres, bar direct-in-band units; field personnel do not need conversion, with a significantly lower rate of error than the converted indirect reading

Read in the open sun.

Note: Super-high-light tube core + dark mask; clear numbers at lux environmental levels; light-sensitivity automatic light-up to balance night vision against dizziness

Multiparameter turnscreen

Description: 2-8 parameters shown on one screen rotation; multiple pump liquid slots at pumping stations, multiple warehouse slots at the material yard, one screen; and provincial screen installation position (multiple cost per parameter stand-alone screen)

Remote Grouping UnCrowded

Description: Remote control + RS-485 grouping; fixed value / scale / rotation parameters high without crawling modifications; reduced operation risk for maintenance of high

Long and strong.

Note: LED life 5 ~ 100000 hours; (b) No motor parts; (a) Industrial-grade structure resistant to vibration (car beam/ tower environment); Modularized assembly, local failure change module repair

Disadvantages and use restrictions

No record, no control

Description and response measures: pure display terminals, no historical storage and reconciliation output; Response: data are recorded by the first second table of source / DCS side (the recorder is part 48/53); Controls to adjusters (Page 49/50/52); This is the location. It's visible. It's not crossed.

Weak alarms.

Description and response: beyond the limit of flashing + interface, no confirmation / startup event recording process; response: full alarm person process to flash alarm (Page 58/59); HALS location "In situ tip" support

Single-parameter blind zone (rounded)

Description and response: an alarm under a rotation mechanism may coincide with the appearance of his parameter, delaying one rotational cycle before attention is given; response: complete key parameter independent screen or symmetrical partition; alert instantaneous entry of an alarm parameter display (smart machine function)

Price spreads

Description and response measures: 1,500-20000 CNY, double the price of word height and outdoor protection per set; response: strict reading distance inversely high, not excessive for "aerobic"; indoor environment not for outdoor grade

Flow and heat spread

Description and response: Large-word high-tech 100-150W, with significant running power and heat per year; outdoor closed-box solar irradiation superheat spreading difficult; response: light-sensitization + high-efficiency tube core model; installation position to avoid sun

Maintenance high cost

Description and response measures: medical check-ups on screens installed at high altitudes are required to perform high-level work; LED light failure to life-changing tube whole screen unloading; Response: Modularized assembly remodels are not disassembled; Selective life 100000 hour tube core length cycle

# The light of night #

Description and response: dizziness peri-sunning of the plant area at night (neighborhood project); response: light-sensitive automatic lighting; installation towards avoiding residential buildings windows

Typical application scenario

Logistics weighs

Typical application scenario: Lmb / RV scale screen (high-pit reading by car driver); Blank wall large on the outside (driver not to get off the bus to see fur weight); Quantification tips for loading vehicles Common configuration: + heavy pulse input + 200 ~ 400 mm + remote control group + outdoor type

Water pumping station

Typical application scenario: pump room liquid screen (watch-to-work to read well-sorting fluid); multi-pump wheel liquid / pressure; movement centre outside main tube pressure; common configuration: 4-20mA input + multi-parameter round display + sound light tower + RS-485

04

APPLICATIONS

Application area

Workshop- and factory-level excursions, mainly for metallurgy, mines, water, cement, logistics, etc., show that typical industries are distributed as follows.

5.1 Four typical application models

Metallurgy

Premise position remote reading (scaling field cross-site reading); display of a crane; iron/ slag temperature screens Communications direct (taken from PLC)+ outdoor highlight + point array

Cement building materials

Base / grinding tablets; yield meter board (class/ daily tons); temperature reference in front of fire television in kiln header + digital dot mix screen + rotation

Electricity and plant sector

Hours at the door of the plant + safe production days viewer; frequency/load of electrical grid outside the main building; cumulative daily coal combustion + signal mix + outdoor IP65 + light-sensitization

Test and line

Test tower load display; production line metronic count; workshop mass viewer (concentrating) encoder / switch input + indoor type + suspension

Mode

Signal path, point.

Simulation excursion

Liquid bit / Pressure Transmitter 4-20mA ⁇ Large screen displays in the simplest mode: large screens are shown twice; scale changes on the side of the large screen; signal and associated attention needs to be paid to load capacity (two-plus separator)

Remarked

⁇ Large screen (inline magnification + marked) ⁇ Print/ upload MV signal for special magnification; mark / dekin / count completed on large screen; and guide packages for reading in high-altitude scales

Communications Direct

DCS / PLC ⁇ RS-485 ⁇ Large screen (pure display terminal) zero-screen clustering; content defined by main station (frequency/ cumulative / days); best-placed (two lines of communication) cross-plant wireless bridge

Multiparameter rotation

Multiroad 4-20mA / Multistation Data Shows a wide screen rotation, multiple screens; stop 5 ~30s per parameter; report police in instantaneously; key security parameters are not visible

Parameter Item

Input signal

Typical specifications: Simulation: 4-20mA / 1-5V / 0-10mA; Pulse: high-speed count (≤ 10 kHz) or mV special; Temperature (variation): Pt100 / K / E; Communications: RS-485 (Modbus-RTU, RRU from station)

Show Range

Typical specification: 1999~9999 (4 bit) or 6 bit cumulative; any grouping of decimal positions; units by point bar (t / m3 / MPa / °C, etc.)

Display accuracy

Typical specifications: 0.2~0.5% FS (simulation input); no cumulative error in the pulse count; the accuracy of the direct visibility of communications depends on the main station data

Show Specifications

Typical specification: LED digital font height: 100 / 200 / 300 / 400 mm; digits 4 / 6 / 8 bits (single or double column); optional 16 x 16 point bar (Handels / unit / hint)

Readable Distance

Typical specifications: 100 mm high, approximately 10~20m; 200 mm about 20~40m; 400 mm about 40~80m (simplistic content ceiling)

Scan with

Typical specifications: dynamic scan, frequency > 100Hz (no flashing sense); constant flow driven, even brightness; brightness manual / light sensitivity automatic reconciliation

Alarm function (optional)

Typical specifications: upper- and lower-limit independent fixed values and back-up; relay points 1~2 points (3A/ 250VAC); screen flash + sound light tower driver end

Communication interface

Typical specifications: RS-485 (Modbus-RTU); remote retrofit and teleconsolidation; wireless bridge selection (cross-site free-wire)

Power supply

Typical specification: 220 VAC ± 15% (mainstream); overall power consumption: indoor 10~60W, large outdoor font 60~150W

Environmental conditions

Typical specifications: indoor type: -10~50°C; outdoor type: -30~60°C (wider temperature power and LED reduction design)

Ingress protection

Typical specifications: indoor IP40~IP54 (open frame or thin box); outdoor IP65 (closed water tank + mine-proof module)

Mounting

Typical specifications: wall-mounted / hanging / pillar-stamped / wall-laying four; suspension load loads weighing at 5 times safety factor (car vibrating environment)

05

TECHNICAL SPECIFICATIONS

Technical Parameter Table

The following table shows typical specifications for super-large screen monitors (general simulation/communication input type), which are based on sample manufacturers.

  1. 01

    Select Table

The price is the price of the full RMB.

7.1 Order code structure (example 8 bits)

  1. 01

    Selection Guide

8.1 Ten Elements of Selected Decision-Making

8.2 Typical scene selection path

8.3 Four procurement acceptances

Summary

The super-large screen monitor is the "television vision" of the industrial site, which extends the reading distance from one or two metres to dozens of metres on the dashboard, allowing drivers, pump station duty, and field control to read key numbers directly to their posts. It is divided into family units: the Trend Archive Register (Page 48/53), the Control Regulator (Page 49/50/52), the Multipoint Surveillance Subspectator (Page 55), the Full Warning Process (Page 58/59), the In-Situ Temperature Quick Read the Wall Regulator (Page 60), and the Remote Reading of the Section "The Man Can't Look Near." Selective logic: First, the remote distance is inverted (not small), second, the input path (with DCS data first-chosen communication) and third, environmental protection and light-sensitization (outdoor class and night dizziness). The 61st series has been completed, showing family formation (wall-mounted temperature + hyper-screen remote reading of two tracks) in situ, followed by signal conversion distribution, electric implementing agency matching, etc.

Technical parameter table . 13 / FormCross-reference
13Configuration methodInfrared remote control (scale / fixed value / round / brightness); RS-485 remote grouping; panel key lock error protection
14ReliabilityLED Life 5 ~ 100000 hours; (b) Modularized assembly (local breakout modelling group); Average ≥ 20000 h
15Safety and protectionPower input mine (outdoor type); metal frame secure location; capped crash redundancy design
Technical parameter table · Slotting / Representative typeCross-reference
TrancheType of representativeTypical ConfigurationPrice of the whole machineTypical applications
Outdoor HighlightLarge-faced outdoor series of national productionIP65 Closed Box + Super-high-light tube core + Mine-protective; high-word 200 ~ 400 mm; light-sensitivity automatic lighting8000-20000 yuanThe kitchen, the outside wall, the factory, the factory, the sun.
Mixed Screen SmartDigital point array hybrid seriesnumeric + Han-dot array; RS-485 Communications Inverted + Remote Grouping; Multiparameter Resize4000 ~ 10000 CNYScheduler viewer, yield count, outside the main building
Standard indoorsStandard set series on national productionWord height 100~200mm+ Simulation / Pulse Input + Upper-Land-Land Alert + Remote Control Group2000 ~ 5000 CNYWorkshop, pump room, test tower, shelf, loft room.
EconomyA simple large-word display box for national productionSingle parameter 4-20mA direct; word height 100mm; no alarm no communication1500 ~ 2,500 CNYAuxiliary distance reading, temporary viewer, budget constraints
bitsMeaningCommon take-up examples
1Broad categories of productsB = Super-Screen Monitor
2Input typeA (4-20mA / 1-5V simulation); P (high-speed pulse); W (heat voltage) (mV); T (Pt100 / thermoelectric voltage); R (RS-485 communications invert)
3Show high fonts1(100mm);2(200mm);3(300mm);4(400mm)
4Digits and Columns4 (4 in single row); 6 (6 in bit); 8 (8 in bit); D (double column)
5Slap the line.0 (none); Z (16x16 HD bar showing bits/ units/ hints)
6Alarm Configuration0 (none); 2 (up to down double relay)
7Protection and installationN (Indoor IP54); W (outdoor IP65 + mine-protected); G (capsulation); B (stretching)
8OptionsL (auto-sensitized automatic lighting); X (wireless bridge); default base
Technical parameter tables · Decision-making elements / Decision pointsCross-reference
Elements of decision-makingElements of judgement
Maximum distance inverted highThe physical distance from the front-line observation point to the screen (drill/ pound drive/ dispatch desk); readable distance = 100 ~ 200 times higher and up; no less - replacement screen costs are much higher than the initial loading margin
Enter path selectionSimulate input for near-range transducer 4-20mA; heavy field mV (all marked on screen); DCS / PLC already available data ⁇ communication in a no-screen format, preferred)
A multi-profile signal load.The same 4-20mA is both a table and a big screen: two tables entered to resist stacking and overloading (usually 500 ~ 750 times); over-plus signal isolation distributor (Runway Interface Family, 43 ~ 45 times)
Reveal or partition?Multiparameters: rounded screens with blind zone cycles; full screens with full parameters but high 50 ~ 100%; key security parameters (relevant to liquid level) are not rotated
Technical parameter table · Environmental and protective level / Indoor workshop IP54 is sufficient; all PBW external walls / material field / portals IP65 + mine-proof; focus on heat dispersion and light decay in the western sunCross-reference
Level of environment and protectionIndoor workshop IP54 adequate; external wall/ field/ portal all IP65 + mine-proof; focus on heat dispersion and light decay in the west sun
Brightness and light-sensitivityOutdoor type must be light-sensitive and automatically lighted: bright enough to read during the day and dizziness-proof at night; the lighting of the neighbourhood housing project is not an option
Installation and LoadingHanging (barrier/ roof) picks the suspension at a 5-fold safety factor; the pole cuddled core vibration (the material field wears a porch vibrate); embedding wall pre-set inspection route - the operational surface of the replacement of the high-end module
Form and avoid heightsAll high screens select remote control + RS-485 double channel grouping; each parameter modification is a risk of a high operation, and remote grouping is safety
Maintenance and light-contaminated managementSelect the 100000 hour tube core and modularized assembly (module remodeling without disassemble); Create a system of annual brightness comparison (light decay 30% planned switch); Outdoor mine-protected site inspections
Border with LED screenShow values and a small amount of text ⁇ in CNY; text / video / dynamically layout ⁇ LED > spelled screen (tens of thousands); do not show a number with the budget of the aggregating screen, nor expect the machine to do the job of the aggregating screen
sceneRecommended programmeRationale
Two-sided screens on the outside of the building.Re-design user external + font height 300~400mm + IP65 + Mine-protected + light-sensitized30m reading in driver ' s car; sunscreening west; decorated remote control completed
Pumping room, snorting wells.Standard indoor +4-20mA + font height 200mm + sound light tower + upper- and lower-limit alert20m reading; high-low-sound light alert; load accounting plus isolation partitioner
Multi-silo position at the field.Mixed Screen Smart + RS-485 Communications Intuitive + Multiparameter Revoltive + Outdoor HighTake zero-constituents from DCS; show 4-8-silo slots on one screen; readable in sunlight
The factory door clock viewer.Mixed screen smart + dot array + Communications Direct + Outdoor + LightSafe labor days updated with main station; Hsu-tai-sensei work; night dizziness
Workshop production line countEconomy or standard indoor type + pulse input + font height 100~200mm + hangerProduction of liner beats and shift production cumulative; motorized gear vibration test; remote control zero
LinkThe point of acceptance.
1. Check-in on arrivalType 8 bit-by-place check (input/ high/ bits/ dot array/ alarm/ protection/ options); screen-level and module sew-up checks; outdoor container sealing and mine-protected module verification
2. Display and precision validationMark variations reconciled with project volume display (sign generator verified at three points); light integrity of the segments (missing / brightness uneven checking); remote reading distance measurement (simulation of real observation point confirmed)
3. Warning and formation testsUp- and down limit and back-up action validation; remote control group full process operation (high-level no-crawl availability verification); RS-485 remote re-profiling and group alignment
4. Environmental and installation assessmentOutdoor shower and sunbath assessment; weight and crash control check for suspension packages; light-sensitization day and night switching observations; light baseline record (retain for light decay ratio against baseline)