Super-Big Screen MonitorClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-BIG-100
Super-Big Screen Monitor
Super-wide monitor, super-large monitor
01
Classification: Super-wide screen monitor
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-BIG-100 |
|---|---|
| Product function | Process data on temperature, pressure, flow, accumulation, class yield, etc. Display at the height of the workshop or outside the gate of the plant area, to be read directly by persons tens of metres or more, in lieu of hand-written boards and walk-in forms; and the same data can be sent to the upper system via Communication mouth, the panel being the source of data |
| Display digits | 4 bit standard optional 5 bit / 6 bit; support decimal position can be set with negative display (ceiling display minus sign); end with unit characters (℃ / MPa / t/h / m3) |
| Character height | 200mm (According to distance) 100m), 300mm (150m), 400mm (200m), 500mm (250m;chars by 7 Paragraph LED Modular spelling, word heights and digits can be combined at any time without modelling for special sizes |
| Display colors | Red (Standard with the best remote penetration and recognition), green, yellow, white; Optional double-colour screen (normal Display green, ultra-automatic red) |
| Brightness | Single LED Brightness ≥6000mcd Fullscreen 8 Level adjustable; automatic luminescence with light (days) 100% At night. 20% It doesn't affect readings at night. |
| Input signal | 4–20mA / 0–10V simulation; RS485 (Modbus RTU, readable register visible); pulse or frequency (used for cumulative and class yields); switch volume (used for state-to-shift switching); a meter that connects 1–2 road and switches by key Display |
| Display conversion | Inside four conversions: linear (range high and low limits corresponding to display high and low limits, reversible), open (differential pressure flow), cumulative (pulse equivalent 0.001–9999), direct reader memory; conversion parameters are set by panel keys or top machines |
| Refresh interval | Simulation 200ms; RS485 rotation 1s (available 0.2–10s); pulse accumulates and falls ≥10 |
| Totalizing function | Optional class accumulation, day accumulation and aggregate accumulation statistics, zero by key and zero by recording time and pre-zero values; shift statistics continue to accumulate after power outages have been restored, and no jump-off statistics are lost |
| Alarm indication | Full screen blinking or digital colour change (two-colour screen) over the limit, and drive (250VAC/2A) acoustic Alarm |
| Communication interface | RS485 (Modbus RTU from station/home station optional); optional Ethernet, 4G/NB-IoT (replace display readings remotely and return status), LoRa (wireless interface with live instrument, provincial wire) |
| Power supply | AC 85–265V (50/60Hz), 30–120VA; optional DC 24V |
| Box structure | Aluminium alloy-type frame + 1.5mm cold-rolling plate backboard, surface static powder coating; front 5mm Yakle panel (Optional steelized glass); post-opening and overhaul of the module, with single block replacement |
| Ingress protection | IP65; outdoor type IP66 (requires protection against rain lids and drainage); working temperature -30–+70℃ |
| Mounting | Walls (four reinforced ears on the back), poles, hangers (top rings); outdoor screens to the north or shades of the sun to avoid a decrease in contrasts as a result of direct exposure at noon |
| Overall dimensions | In bits and heights: 4 × 300mm approximately 1600×600×120mm 4 × 500mm approximately 2600×900×150mm 6 × 500mm approximately 3600×900×150mm |
| Instrument weight | 35kg (4 × 300mm); 6 × 500mm 120kg installed with more than two persons and a hanger |
| Applicable standards | GB/T 34037 (Industrial Process Measurement Log) / GB/T 17626 (EMC) / GB 4208 (shell Ingress protection) |
| Typical applications | Workshop production and rhythm panels, cumulative publicity of water and sewage plant flows, temperature pressure publicity of power plants and heating stations, grain storage and port metering boards, safety indicator tips for plant gates, front of exhibition halls and movement control centre screens Display |
| Product features | LED Modular cipher, word height and digit free combination, special sizes not to be modeled; simulations, RS485, Pulse, old instruments and new systems are usable; light is automatically lighted and clear day and night; cumulative power outages are maintained, shifts and jumps are not lost; then open the door structure, single modules can be replaced on site |
Product selection
VISCON-BIG-100| Code | Display digits |
|---|---|
| N4 | 4 bit (Standard) |
| N5 | 5 bit |
| N6 | 6 bit |
| N44 | 4 + 4 Double row (two arguments and screen) |
| Code | Character height |
|---|---|
| H200 | 200mm (approx. distance 100m) |
| H300 | 300mm (approx. 150m, Standard) |
| H400 | 400mm (approx. distance 200m) |
| H500 | 500mm (approx. distance 250m) |
| Code | Display colors |
|---|---|
| C1 | Red (Standard) |
| C2 | Green |
| C3 | Yellow / White |
| C4 | Double colour, over-limit automatic red. |
| Code | Input signal |
|---|---|
| I1 | 4–20mA simulated amount |
| I2 | 0–10V simulated amount |
| I3 | RS485(Modbus RTU) |
| I4 | Pulse / Frequency (cumulative) |
| I5 | Double-track input, key switch (Standard) |
| Code | Conversion function |
|---|---|
| F1 | Linear conversion (reverseable) |
| F2 | Starter conversion (Differential pressure flow) |
| F3 | Cumulative Pulse equivalent conversion |
| F4 | Linear + Cumulative Parallel (Standard) |
| Code | Communication and remote transmission |
|---|---|
| T1 | RS485 |
| T2 | RS485 + Ethernet |
| T3 | RS485 + 4G / NB-IoT |
| T4 | LoRa Wireless (matched with live instrument) |
| Code | Enclosure and protection |
|---|---|
| B1 | Indoor type IP65 (Standard) |
| B2 | Outdoor type IP66, protected from rain |
| B3 | Stainless steel Boxes (corrosive environment) |
| Code | Installation and power supply |
|---|---|
| V1 | Walls, AC 220V |
| V2 | AC 220V |
| V3 | Hanging, AC 220V |
| V4 | Walls, DC 24V |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us