PRODUCT TECHNOLOGY
Pressure Checker
Operating principle
Pressure checker.
The verification table pressure system consists of "exact + steady pressure + fine-tuning + distribution" level . (b) Pressure-reducing valves for the gas in the air pressure system using an electric diaphragm pump or external filling cylinders; (a) Hydraulic pumps are used in hydraulic systems, which are amplified by medium-pressure-enriched cylinders (pressure ratio 10:1 ~100:1); Vacuum systems use a rotor/dural vacuum pump, which can reach MPa (table pressure). (b) The pressure tank (energy collector) flattens the pump output pulse; (a) A fine-tuned valve / fine-tuned tank with a linear volume change of 0.005% of the FS class adjustment; The multiple-position distribution valves synchronize the same pressure to the school watch. Pressure stability is the core indicator for the calibration station - the semi-automatic station requirement. ±0.02% FS/min, full-autobar console through PID closed loops in Zhum ±0.005% FS/min。
- 01
Auto-placed points. Stable standard collection values and individual detected values after the determination has been met (transmitters passed)
- 02
Control pressure-by-point approach (excuse containment strategy)
- 03
1 Task creation • Recording / Identification of reviewed information, Selection protocol template • Support for multiprogramming template library • Checking task orders
- 04
2 • Platoon-mounted, sealed, gasket-covered, open, open-table valves. ≤ 1 Min, check the circuit.
Structure
Pressure checker. Structured composition.
By "Pressure-increstrial system + Pressure-push micro-modulation system + Standard system + Checking table + Control / Typical Aerodynamics: ⁇ Gas source (pump/ cylinder) filtering pressure-reducing tank ⁇ Main cut-off valve ⁇ Micro-modified valve ⁇ Pressure mother tube ⁇ Cursing of surface-debarrel ⁇ School Watch (checked + Standard-Purpose-Consolidated). The hydraulic system adds on this basis tanks, circuits and filters, and when the test is completed, the fluid is recovered to the tank by the excretion valve. The tube and valves of the high pressure system (>60 MPa) are sealed with cones or lens pads and mechanical shields to prevent blasts. The two media systems of the fluid shall be physically isolated to prevent contamination damage from hydraulic fluids entering the gas-activation standard.
- 01
1 Pressure-incident pump team · Electric gas pump / hydraulic pump / pressurized tank = 0~250 MPa grade, continuous working system
- 02
2 Vacuum pumps - 0.1 MPa vacuum zone / rotor / diaphragm, retro oil
- 03
3 · Pressure cans / Energy collector • Pressure pulse flattening ~ 2-10 L volume, stress resistance matching ~
- 04
4 • Micro-organizing institutions • Precise proximity of calibration points • Micro-resolution 0.005% FS Level .
Application area
Pressure verification stations . Application areas
The complete description shows the technical sections.
- 01
1 Measurement technical agency review • Social utility measurement standards set, external mandatory check • Piston benchmarker + licensing system
- 02
2 Enterprise Metrology Office Periodically calibrated the plant pressure sheet / Transmitter semi-automatic multiple tabulation, efficiency priority
- 03
3 instrument manufacturing plant • Pressure gauge / Transmitter exit check and check · Production line integration, high beat .
- 04
4 Third-party calibration laboratories ; External calibration services (CNAS accreditation project) + 17025 system
Selection Guide
Pressure checker. Selecting guidelines.
Summary: Pressure checker is structured as a whole with "pressure / vacuum occurrence system + steady fine-tuning + standard unit + multi-platform surface + control and data system" and is upgraded from "system" to "volume line" and is the core equipment of the measurement facility and the enterprise metering office. The selection is based on the "Annual Measurement of Pressure Ranges" (AQS) Media System Quest Standard Machine Program (STP) Quote Numbers Query Signal Channels Query Software functionality Qualifications and Full Cycle Cost of Environmental Conditional Compliance" decision, which adheres to the Standard Vehicle 1:4 Precision and Pressure Stability (PQS) principle, which achieves the best balance between efficiency measurement, accuracy measurement and investment economy.
- 01
Manual Handshake pump + Standard Table + Desktop 15~20 min < 200 block/year 10000 ~ 50000 CNY
- 02
Semi-automatic Electric pressurization + computer count 5~8 min 200 ~ 2000 block/year 50000 ~ 200000 CNY
- 03
Full Autotype PLC Closed Circle + AutoList 3~5 min > 2000 block/year 200000 ~ 800000 CNY
- 04
Production line integration Transfer / Robot + Full Auto ≤ 2 min Production of meta-synthesis in manufacturing plants Customise above 800000 CNY
Model Selection SELECT A MODEL
1 ModelPressure checker selection support
Provide survey missions, media and installation conditions and obtain product configuration advice.
Contact us