PRODUCT TECHNOLOGY
Thermal resistance for temperature measurement at stations
Operating principle
Thermal resistance to temperature measurement at the station.
The temperature element is measured by the electrical resistance value of platinum based on a single temperature change, using Pt100 or Pt1,000 platinum. Platinum resistance temperature is following international temperature standards. ITS-90 Electro-temperature relationship -200 ~ 0 ℃ and 0 ~ +650 ℃ The region is described in different ways: R0 = 100 Ω( Pt100 ),A = 3.9083 × 10 ³ ℃¹,B = -5.775 × 10 ⁷ ℃²,C = -4.183 × 10 ¹²℃⁴。 Pt100 100 times at 0 °C and 138.51 times at 100 °C, with an average temperature factor of approximately 0.385 per °C. The core is the hot tubing.
- 01
200 ~ 0 ℃:Rt = R0·[1 + A·t + B·t² + C·(t-100)·t³]0 ~ +850 ℃:Rt = R0·(1 + A·t + B·t²)
- 02
Low pressure PN ≤ 2.5 ≤ 2.5 QVV, Water Supply, Water Return / Straight pipe / Thread Connection
- 03
Medium pressure PN 4.0 ~ 10 ~ 4.0 ~ 10 % Medium pressure boiler water, superheated steam % direct pipe / welding / incremental
- 04
High pressure PN 10 ~ 25 ~ 10 ~ 25 QP boiler overheater, reheater = Gradient/ Step/ Whole exercise
Structure
Thermal resistance to temperature measurement at the station
The configuration is confirmed by medium, measurement mission and installation environment, in conjunction with technical information on thermal resistance for thermal monitoring station. The technical sections are available in the complete description.
- 01
1 Temperature element (plyptunium resistance) · Temperature-temperature-Treatment Core . Pt100/ Pt1000 film or circuit, level A / B
- 02
2 Internal protection tube . Pt100 Component Protection and Guidance . Inconel 600 / Haps C-276/ 1cr18Ni9Ti / 316L
- 03
3 • Thermal tube (herm owell) . The pressure containment, high pressure vapour medium, which is the key to temperature measurement at the power station. 12 Cr1MoV / 15 CrMo / 1 Cr18Ni9Ti / F22 / F91 / Weld Inconel 600
- 04
4 Inline spring (invitro). Supporting temperature, dispersive vibration stress. Inconel 600 / 316L spring
Application area
Thermal resistance for temperature measurement at power stations
The configuration is confirmed by medium, measurement mission and installation environment, in conjunction with technical information on thermal resistance for thermal monitoring station. The technical sections are available in the complete description.
- 01
Boiler overheater export · High temperature overheat 540 ~ 620 °C / 10 ~ 25 MPa / 30 ~ 80 m/s. Whole exercise + Inconel 600 welding
- 02
The boiler reheater is imported and exported · Thermal steam 540 ~ 610 °C / 4 ~ 10 MPa + Inconel 600 Protection tube
- 03
Screen overheating · High Temperature Overheat 450~620 °C + 1Cr18Ni9Ti / Inconel 600
- 04
· Primary steam export 540~620 °C / 17~25 MPa & Whole exercise + welding Inconel 600
Selection Guide
Thermal resistance to temperature measurement at the station.
The configuration is confirmed by medium, measurement mission and installation environment, in conjunction with technical information on thermal resistance for thermal monitoring station. The technical sections are available in the complete description.

Model Selection SELECT A MODEL
1 ModelThermal resistance type support for temperature measurement at stations
Provide survey missions, media and installation conditions and obtain product configuration advice.
Contact us