Thermal resistance for temperature measurement at stationsClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

TEMPSEN-RT-300

Thermal resistance for temperature measurement at stations

Thermal resistance for temperature measurement stations, and thermal resistance for temperature measurement stations

01

Classification: Thermal resistance for temperature measurement at power stations

02

Check configuration based on field work

⁇ Classify thermal resistance for temperature measurements at the back station

TECHNICAL SPECIFICATIONS

Technical specifications

TEMPSEN-RT-300

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelTEMPSEN-RT-300
Measurement principlePt100 resistance value changes linearly with temperature (R0=100Ω, α=0.00385), converted from variable/ Display instrument
Sensing elementPt100 duplex three-wire (standard Configuration, one running back-up; optional Pt100 simplex, Pt1000, Pt100 Duplex Four-wire
Sensor typePt100 (Pt385) corresponds to IEC 60751 / JB/T 8622; can provide Pt100 (Pt391) old score (Specify when ordering)
Measurement range-200–+600℃ (conventional -50–+500℃, power station soda system typical 0–+600℃)
Accuracy classA Level ± (0.15+0.002 | t |) ℃ / B Level ± (0.30+0.005 | t |) ℃; duplex Coherence ≤0.1℃
ConstructionMineral-insulated duplex: φ4–φ6 mineral-insulated core (duplex) + 316L/1Cr18Ni9Ti protectet + waterproof or Flameproof Junction box
Protection tube material1Cr18Ni9Ti / 316L stainless steel (standard) / 12Cr1MoV heat-resistant steel (barrel and high temperature segment)
Protection tube dimensionsφ12 / φ16 / φ20 × L (insertion depth 75–1000mm Optional); Optional cone strengthening head and thicker wall (Erosion resistant)
Process connectionM20×1.5 / M27×2 thread (standard); or DN25–DN50 flange (PN2.5–PN16); or welded seats (barrel)
Junction boxWaterproof cast iron /Aluminium Alloy junction box IP65 (standard); optional 316L stainless steel box flameproof Ex d II C T6
WiringDuplex Three-wire (three lines per unit, independent source); Optional Four-wire
Response timeAnd 0.5 ≤15s (φ16 protection tube, current speed ≥1m/s)
Insulation resistance≥100MΩ (500VDC, constant temperature); ≥20MΩ (500VDC, high temperature 300℃ later)
Vibration resistance10–500Hz, amplitude 0.35mm, meeting GB/T 2423 and auto-engine body resistance requirements
Pressure withstand ratingProtection tube 1.5 times nominal pressure 1min no leakage; soda pipe type PN16–PN25
Ambient temperature-40–+80℃ (junction box); optional high-temperature type junction box +150℃
Operating pressureConstant pressure –25MPa (high pressure for water/main steam pipe type, Specify when ordering Pressure rating)
Output signalDuplex RTD signal (third line) / integration 4–20mA + HART transport (Optional, one measure variant)
Ingress protectionIP65 / IP67 (Optional)
Applicable standardsIEC 60751 / JB/T 8622 / GB/T 30429
Suitable operating conditionsPyrotechnic and nuclear power plant main steam, reheated steam, water supply, condensed water, pump export, engine axle metal temperature, generator stationary cooling water, deoxifier and heater side of the gas, etc.
Product featuresDuplex redundancy design satisfied DCS double-channel capture and failure determination; mineral-insulated core resistance to shock, adaptation crew startup and high current speed flushing; insertion depth and thread customized to the crew spot map, corresponding to the end of DCS

Product selection

TEMPSEN-RT-300
Sensing element / sensor type
CodeSensing element / sensor type
P1Pt100 Duplex 3line (Standard)
P2Pt100 Duplex 4
P3Pt100 Simplex 3line
P4Pt1000 Duplex
P5Pt100 (Pt391 old score, Specify when ordering)
Measurement range
CodeMeasurement range
L1-50–+200℃ (axis/cool water)
L20–+400℃ (water/coagulation)
L30~+500℃
L40–+600℃ (Main steam/reheat)
Accuracy class
CodeAccuracy class
E1Level A
E2B Class (Standard)
Protection tube material / diameter
CodeProtection tube material / diameter
M11Cr18Ni9Ti φ12
M2316L stainless steel φ12 / φ16 (Standard)
M3316L thick wall φ20
M412Cr1MoV heat-resistant steel (barrel/high temperature segment)
Insertion depth L
CodeInsertion depth L
D175 / 100mm (axis, thin pipe)
D2150 / 200mm
D3300 / 400mm
D4500 / 750 / 1000mm (Specify when ordering)
Process connection
CodeProcess connection
F1M20×1.5 Thread
F2M27×2 Thread
F3DN25–DN50 flange PN2.5 / PN6.4
F4Flange PN16 / PN25 (high-pressure soda pipe)
F5Welded seats (barrel buried/direct welded)
Junction box type
CodeJunction box type
X1Waterproof cast iron IP65
X2316L stainless steel IP65 (resistible)
X3High-temperature type junction box (Environment ≤150℃)
X4Flameproof Ex d II C T6 Gb
Output signal
CodeOutput signal
O1Duplex RTD signal (Standard)
O2One RTD + 4–20mA transmitting
O3Duplex 4–20mA + HART transmit

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
TEMPSEN-RT-300 RTD for Power Plant Temperature Measurement