PRODUCT TECHNOLOGY

Stainless steel resists shock point pressure table

Operating principle

The stainless steel resists the shock point pressure table.

(YNXC-BF / YNXC) is the integrated large-form of four techniques, "Pressure Table + EMP Control + EMP + EMP + Total stainless steel Preservative" which can be understood as superseding seismic structures based on the magnetic-assisted point pressure table (YXC) and upgrading the entire parts to stainless steel. It is oriented towards the most demanding type of work at the industrial site: medium pulse + mechanical vibration + corrosive environment exists simultaneously and requires pressure alert/lock control. (b) The electro-exposure signal needles are equipped with a recommensible permanent magnetic steel: the magnetic field is increasing the insulation of the point, accelerating the contact movement, and the contact point is reliable; The resistance structure effectively inhibits the hand-held and impact, protects the points of contact, and provides clear signaling, telecommunications switching and reliability. Set value accuracy: connect ± 1.6% FS

  1. 01

    The measured medium pressure enters the spring tube (boden tube) and the free end produces elasticity;

  2. 02

    (a) The lifting of the pole, the gearing apparatus, and the boosting of the pointer (with a moving pointer) to indicate pressure;

  3. 03

    (a) The set pointer on the tableboard (1~2 scalable) has a static contact head, the position being set by the button on the watch glass;

  4. 04

    (a) An automatic control and alert by electrical elements such as relays, when the pressure reaches the fixed value, or by a static contact (or break-up);

Stainless steel resistance to shock point pressure table selection support

Provide survey missions, media and installation conditions and obtain product configuration advice.

Contact us
Stainless steel resistant to shock point pressure table

TECHNOLOGY & APPLICATION

Understand the principles, the exact selection.

From measurement principles to field applications, the technical characteristics and selection elements of the barbed steel shock-resistant pressure table are understood.

01

MEASUREMENT PRINCIPLE

Measurement principle

(YNXC-BF / YNXC) is the integrated large-form of four techniques, "Pressure Table + EMP Control + EMP + EMP + Total stainless steel Preservative" which can be understood as superseding seismic structures based on the magnetic-assisted point pressure table (YXC) and upgrading the entire parts to stainless steel. It is oriented towards the most demanding type of work at the industrial site: medium pulse + mechanical vibration + corrosive environment exists simultaneously and requires pressure alert/lock control.

1.1 Principles of measurement and control (basic layer)

  1. 01

    The measured medium pressure enters the spring tube (boden tube) and the free end produces elasticity;

  2. 02

    (a) The lifting of the pole, the gearing apparatus, and the boosting of the pointer (with a moving pointer) to indicate pressure;

  3. 03

    (a) The set pointer on the tableboard (1~2 scalable) has a static contact head, the position being set by the button on the watch glass;

  4. 04

    (a) An automatic control and alert by electrical elements such as relays, when the pressure reaches the fixed value, or by a static contact (or break-up);

  5. 05

    Form of control

    Upper and lower limits, double ceilings, double floors.

1.2 Magnetic aided points of contact (reliability layer)

E-exposure pins with trombobled permanent magnets.

(a) Magnetic field force increases the suction of the points, accelerates exposure movements and has reliable contact;

(b) Elimination of arcs to avoid frequent disruptions and burns of the contact points caused by vibration or pressure pulses;

The contact power can be 30 VA (high power 50VA), with long life and reliable mail.

1.3 Seismic Resilient Principles (Effort Level, Core Increase of this Model)

Four-fold interdiction measures based on YXC

  1. 01

    Filling with a nitric fluid - the shell is filled with silicon/glycerine to inhibit the hand-held shaking and buffer the media pulse impact;

  2. 02

    (b) Interdiction tube - restricted pressure transfer channels, smoothing of pulsed pressure waves;

  3. 03

    (b) Blocked nitro - core motion parts are fitted with a blocker to absorb vibrational energy;

  4. 04

    Blocking the nymphoctal - the conjunction is being kept up, reducing the impact of the pressure peak on the spring tube.

The resistance structure effectively inhibits the hand-held and impact, protects the points of contact, and provides clear signaling, telecommunications switching and reliability.

1.4 Control performance indicators

(b) an indication accuracy of 1.6;

Set value accuracy

± 1.6% FS; disconnect ± 4% FS (YXC type)/ ± 5% FS (YNXC shock resistant type, resistance to nitric error);

Resisting condition.

Working environment vibration frequency ≤25 Hz, amplitude ≤0.5mm;

Contact capacity 10/30/50VA (vision type) not directly driving the large power load.

02

PRODUCT STRUCTURE

Structure

2.1 Overall composition

Measurement system (clarine, docking, snail-retarding) + indicator (chip, pointer, pallet) + magnetic aided pointer (set pointer, magnet, head-to-head group) + seismic system (train, tube, blocker) + total stainless steel shell + wire box/ stainless steel plug-in.

2.2 Total stainless steel configuration (BF type)

Generating Group Logic

Magnetic aids (C)x seismological (N)x stainless steel (BF)x Installation (Range/Aximity/Language)x Segregation (Frower) free combination.

Applicable standards

GB/T 1226 (pressure table), seismicity reference JB/T 6804; validation of JJG 52.

Shell

Materials: 304/316 stainless steel

Core/measurement systems

Materials 316 stainless steel

Connect.

Materials: 304/316 stainless steel, M20x1.5 (G3/8, G1/2 custom)

Touching.

Materials: Silver nickel alloy (high pressure) / Gold (low pressure)

Filling fluid

Materials: Silicon oil (conventional) / glycerine

Connect

Materials: stainless steel plug-in + waterproof wire box (IP65 to customize)

Model

Material: Name Characteristics

YX-100/150

Materials: EMP pressure table Base type, contact 10VA, earthquake intolerant

YXC-100/150

Materials: Magnetic aided electrical point pressure table Magnetic aid 30VA, anti-insistence

YXC-100BF/150BF

Materials: Total stainless steel power point pressure table

YNXC-100/150

Materials: EMP pressure table x : tremors

YNXC-100BF/150BF

Materials: Total stainless steel resistant to seismic point pressure table + magnetic aid + all stainless steel (this model)

YNXC-100ZT

Materials: Stunny-resistant side of the axis

YNXC

Materials: BMS Isolated Tube 1/2/3/4/6/8m (2m priority), Corrosion/High Temperature Media

03

TECHNICAL GUIDE

Advantages and disadvantages

3.1 Advantages

Combined capabilities - measurement, instruction, control, earthquake resistance in one table

(b) The most protective dimension of mechanical pressure meters is the type of steel preservatives that are superseded in stainless steel;

Product features

Visibility is significantly better than YXC - Filled with a nitric fluid + a tube + a blocker + a four-heavy snail measure, with clear instructions and connections to be reliable in a vibration frequency ≤25 Hz, amplitude ≤0.5mm;

Long life of the node - the DPT protection of the node from vibration

Magnetic arc reduction burners and high frequency pulses are reduced by several times the normal electrical feeder table;

Touch power - 30VA standard, 50VA high power type

Directly driven small relays;

Corrosion resistant - all stainless steel parts

(a) More corrosive mediums can be measured and correctly sent (YNXC-BF type);

Quantities cover extremely wide - -0.1~0 to 0~250MPa

(a) A vacuum link, the most important of the power point family;

Set visual - the upper and lower limit set pointer is displayed directly on the dashboard and the on-site knob is adjustable;

Free-to-segregate - BMS segregation (1-8 m) detects high temperature and strong corrosive media

(a) The header is placed in a secure position;

(b) No complex power supply - dry point output, simple access control systems;

The value for money is still high -- compared to the "Small Resilient Transfunctioner + Digital Control" program.

The cost of simple circuits has been reduced significantly.

3.2 Disadvantages and limitations

Use limits

Further deterioration of the disconnection accuracy - the shock resistant breakure accuracy ± 5% FS (normal magnetic aid ± 4% FS), the retardation of the nitrics and the switch-off, and limited control precision;

Respond slowest - NCD/NTP + Filled-in-barrel

(b) The stress mutation response is significantly delayed and is strictly prohibited for use in fast-track security chains;

Use limits

(b) Temperature range narrow - concussion-resistant media allowed temperature -25 ~55 °C (non-shock resistant YXC -40 ~70 °C), filling fluids being a limiting bottleneck;

Filling fluid maintenance burden - periodic observation of whether the filling fluid is transparent and leaking

Dust or drop in liquid levels to be repaired;

The capacity of the contact point remains limited - the 50VA cap and the large power load must still pass through the intermediate relay;

Vertical installation requirements - oil-filling shell sensitivity to installation

(a) Axle direction/reverse shall be ordered in a type that affects accuracy and lifetime by misloading;

High price - about 3 ~ 6 times the average point of call;

Use limits

Vibration ceiling presence - severe shock and continuous vibration over 25 Hz/0.5 mm still damage the instrument;

Only output switches - no analogues are remotely transmitted and cannot be recorded in DCS trends;

Use limits

The base spring tube contact medium - crystallization, condensation, high viscosity media - remains to be selected for quarantine or diaphragm-based production.

04

APPLICATIONS

Application area

4.1 Typical application scenario ( "Vibration/Viral + Control" compound)

4.2 Typical control circuits

YNXC interface ⁇ Intermediate relay ⁇ Contact ⁇ Electric/Electromagnetic Valves; or Acoustic Light Alert. Classic application: Hydraulic station oil pressure protection - oil pressure below lower limit alarm and locking down, above upper limit alarm and depressure.

4.3 Select location determination (level by level within the Electro-Performance family)

(a) Vibration-free, corrosion-free, control of ⁇ YX / YTX Electron Point Table;

Applications

No vibration, corrosive, control of all stainless steel power points;

Vibration/pulse, non-colorized, need to control ⁇ YNXC seismic magnetic aided connection points;

Applications

Vibration/pulse + corrosive to control YNXC-BF Stainless Steel Resisting EMPs (this model);

Applications

(a) Medium crystal/high temperature + vibration + control YNXC separation (browsing) derivatives;

Requires high precision control or penetration of DCS ⁇ shock resistant pressure transmitter + control system.

Engineering machinery/hydrovoltage systems

Typical performance: Hydraulic alarm at hydraulic pumping stations, oil pressure chains (continuous vibrations) Recommended configuration: YNXC-100BF, scale 0 ~ 25 / 40MPa

Petroleum chemicals

Typical: Pulse pressure alert for jet pumps (corrosion atmosphere) YNXC-100BF + Separated hoses

Compressor/air pressure station

Typical: Expulsive pressure high and low pressure protection (vibration + pulse) Recommended configuration: YNXC-150 Upper and Lower limit double control

Electricity/metallurgy

Typical: wind, lubricants oil pressure alerts YNXC-100BF

Ship/season

Typical: cabin vibration + salt fog corrosive environment Recommended configuration: YNXC-BF + waterproof wire box (IP65)

Mine machinery

Typical: rock scrawling, hydraulic monitoring of shredding equipment (strength) YNXC-100BF Power model

Pressure vessel/firefighter

Typical condition: self-activation (pump pulse) of the pressure system

05

TECHNICAL SPECIFICATIONS

Technical Parameter Table

5.1 Table of general parameters

5.2 Model slotting table

Technical parameter table · Parameter / SpecificationCross-reference
ParametersSpecifications
Model SeriesYNXC-100/150, YNXC-100BF/150BF (all stainless steel), YNXC-100ZT (disk)
Dial diameterΦ100、Φ150
Indication accuracyLevel 1.6
Set value accuracy± 1.6% FS; disconnect ± 4% FS (YXC)/ ± 5% FS (YNXC shock resistant)
Measurement range-0.1~0; -0.1~0.06 to -0.1~2.4 (joint); 0~0.16 to 0~60 (conventional); maximum 0~250MPa
Head-to-head power10VA (base) / 30VA (magnetic aid standard) / 50VA (high power)
Example of the capacity of pointsAC 220V 3A / DC 24V 5A (destructive load)
Maximum working voltageAC 380V(220V)/ DC 220V
Form of controlUpper and lower, double upper, double lower
Ambient temperature−25~+55℃
Allow Media Temperature-25 ~55 °C (shock resistant; non-shock resistant YXC ~ 40 ~ 70 °C)
Resisting condition.Vibration frequency ≤25 Hz, amplitude ≤0.5mm
Ingress protectionIP64 (standardization); waterproofing box up to IP65 (customization)
Shells/core material304/316 stainless steel (BF fully stainless steel)
Filling fluidSilicon oil / glycerine
Connection ThreadM20x1.5 (G3/8, G1/2 customizable)
Mounting configurationZT
Length of isolation hoses1/2/3/4/6/8m (2m for priority length)
Implementation/approval criteriaGB/T 1226, JB/T 6804 (earthquake resistance), JJG 52
Technical Parameter Table . Model / TablesCross-reference
ModelTable PathRangeHead-to-head powerProcess medium temperatureCharacteristics
YXC-100/150Φ100/1500~0.16~60、−0.1~0.06~2.4MPa30VA−40~70℃Magisuke, you're not gonna be able to hold a shock.
YXC-100BF/150BFΦ100/150Ibid.30VA−40~70℃All stainless steel.
YNXC-100/150Φ100/150Ibid., extended to 0~250MPa30VA−25~55℃Neo-Cyprim.
YNXC-100BF/150BFΦ100/150Ibid.30/50VA−25~55℃Zoom-resistant + all stainless steel
Performance ItemYXYXCYXC-BFYNXCYNXC-BF
Head-to-head power10VA30VA30VA30VA30/50VA
Resisting/anti-pulseBadGeneralGeneralYuYu
PercussionBadBadYuBadYu
Disconnect Precision±4%±4%±4%±5%±5%
Media temperature limit70℃70℃70℃55℃55℃
Price ratio11.31.82.53~6
06

SELECTION GUIDE

Select Table

6.1 List of parameters required for ordering

  1. 01

    Name of the detected medium, corrosivity, purity, pulse level;

  2. 02

    Control requirements

    (a) Upper and lower limit set values, number of points, controlled uses (alerts/locks out);

  3. 03

    Work pressure range ⁇ Quantum range (silent load ≤3 / 4 cap);

  4. 04

    Environmental vibration levels (frequency, amplitude, cross-checking of ≤25 Hz/ 0.5mm boundary);

  5. 05

    Media and ambient temperature confirmation range - 25 ~ 55 °C, type of filling fluid;

  6. 06

    (b) System voltage and load ⁇ contact capacity reconciliation (10/30/50VA slot);

  7. 07

    Material requirements (general carbon steel shell or BF completely stainless steel);

  8. 08

    (a) Table routing, installation form (repeated/axis/side ZT), and the specification of the link screw;

  9. 09

    Whether the stand-alone hoses and lengths, and whether the waterproofing box (IP65).

6.2 Decision sheet for model selection

6.3 Rules for matching contact and load

  1. 01

    Load VA x safety factor (≥2) ⁇ contact capacity;

  2. 02

    (a) Sensible load (exposure) coil safety coefficients of 3-5 or required intermediate relays;

  3. 03

    (b) The voltage does not exceed the maximum of AC380V / DC220V;

  4. 04

    (b) The gold-tangular version of the low-voltage small signal;

  5. 05

    The backway with high frequency breakout is considered for the pressure switch/transmitter programme.

6.4 Quantities and rules of creation

⁇ Measurement upper limit 3 / 4; instantaneous pressure not exceeding full quantities;

Set values to be set between 20% ~80% ranges;

(a) The > exchange differential at the upper and lower limit to prevent the start-up vibration;

Whether or not the nuclear control requirements of the ±5% FS are met by disconnection accuracy.

6.5 Use point

  1. 01

    (a) Anticipated (axis/repeated) by table, with as much vertical as possible of the filling type, with a misload affecting accuracy and lifetime;

  2. 02

    Forced regulation of set points in a severe embargo line - adjustment of upper and lower limits in a state of strangulation using a special tool;

  3. 03

    Cut the power before the connection, check the voltage to match the capacity of the point of contact and prevent overload burning of the point of contact;

  4. 04

    (b) High power loads are always driven by intermediate relays;

  5. 05

    Regular observation of filling fluids

    Dust, drop in fluids and leaks must be repaired in a timely manner;

  6. 06

    Avoiding severe shocks and continuous vibrations exceeding 25 Hz/0.5 mm;

  7. 07

    (a) Reduction of the detection cycle in the vibrating or corrosive environment, with a recommendation for annual validation;

  8. 08

    (b) The slow release of system pressure during dismantling maintenance and avoidance of filling fluid spray;

  9. 09

    The media are limited to copper alloys and 316 stainless steel non-corrosive (composability/crystal selection of the quarantine or diaphragm derivative).

Selective Table . Work Group / Recommended ModelCross-reference
Work GroupRecommended Model
Vibration + Pulse + Corrosion Environment (this type of target scenario)YNXC-100BF / 150BF
Vibration + Pulse, Clean Media Non-CrossYNXC-100 / 150
No vibration, corrosive environment.YXC-100BF / 150BF
No vibration, no routine environmentYX / YXC
Medium High Temperature/ Strong Corrosion + VibrationYNXC isolation (bloster 2m first)
Disk MonitorYNXC-100ZT
Power relays are directly drivenLarge power type (50VA)
07

TECHNICAL GUIDE

Horizontal contrast

Select the mode.

The environment is still corrosive, with YNXC-BF fully integrated; x-nibopt points, Vs and relays;

The response slows down, the heat is high, pressure is different.

Based on the latest samples from the manufacturing plants.

Horizontal contrast · Contrast / Seismic Resisting Point of stainless steel YNXC-BFCross-reference
ComparativeStainless steel earthquake-resistant relay point YNXC-BFMagnetic Auxiliary Points YXCStainless steel earthquake-resistant table YBN (no point attached)Stunny pressure transmitter
On-site instructions.Yes.Yes.Yes.None (numbers visible)
Control the signal.Switches 30/50VASwitches 30VANone4~20mA/number
Vibration/pulseYu (Quadrupted)GeneralYuYu
PercussionYu (total stainless steel)BadYuVisual Structure
Maximum of the scale250MPa60~100MPa160MPa100MPa Level
Disconnect Control Precision±5%FS±4%FS—±0.2%~0.5%FS
Response speedWorst (multiple block)Come on.SlowCome on.
Media temperature limit55℃70℃Visual Filling100℃+
PriceMedium HighLowMediumHigh
PositioningVibration + pulse + Corrosion process instruction and controlGeneral situation controlVibration status pure indicationVibration condition continuous measurement control