PRODUCT TECHNOLOGY
Non-resulting steel sheet pressure table
Operating principle
The stainless steel sheet pressure sheet.
The use of a hyphenation box as a sensitive element for measuring micropressures is another technical route that parallels the flex pressure table with the spring tube (boden tube) and specializes in micropressure/negative pressure ranges. When pressure (or negative pressure) of the detector medium acts on the inner cavity of the membrane box, the free end of the membrane box produces the corresponding elastic deformation (place shift), which is amplified by the gear-driven gear transferer, and the measured pressure value is indicated on the pallet by the pointer fixed to the gear axis. (a) The membrane box is made of two round-shaped wave-line film pieces welded along the perimeter (in stainless steel, plasma welding/laser welding): the inner cavity is sealed and vacuumed or filled with a specific gas; The ripple structure allows the film to have a very low degree of rigidity in the axis, and a very small pressure can produce a larger arctic shift (well more sensitive than the spring tube); Use multiples when individual membrane slots are insufficient
- 01
Rate applicable 0.1 MPa (100 kPa) ~ 160 MPa 0.25kPa ~ 100kPa
- 02
The sensitivity of the transducer is low, high, very high.
- 03
Overpressure power, stronger, weaker.
- 04
Application of medium · Gases, liquids = Gases only (micropressure)
Structure
The stainless membrane box pressure sheet. Structure composition.
(a) Console: regular brass HPb59-1; stainless steel is corrosive in the form of SUS 316,22mm quadrilateral, screw M20x1.5 (detailable); Membrane cartridges (sensitive components): bi-metal membrane cartridges, welding, common type tin copper QSn6.5-0.1; The stainless steel preservative is a double SUS316 film box with plasma welding/laser welding, which is resistant to corrosiveness and welding is significantly more reliable. Gear transfer apparatus (core): The normal is copper alloy core, the preservative steel core, and mechanically magnified the small agular position. Micro-motion zeroing: Most model labels (be located outside the dashboard) can easily adjust the instrument Zeros - Membrane-type meters due to temperature drift and creeping, and the Zeros are routine routine routines for daily maintenance. Normal type (YE)
- 01
Base YE-60 / 100 / 150 QC Copper alloy conductor system + Steel shelljet to measure non-corrosive gas micropressure of copper alloy
- 02
Persistence Pyrotechnics YEF-100/160 Total stainless steel (316 joiner/film box + 304 shell), high-resistence corrosive conditions
- 03
Imbrane cartridge stainless steel. YTFE-60~150. Pressure system and shell. 1Cr18Ni9 stainless steel.
- 04
· YEF-100-B/Z-B . Radial/axis variants, range to ±30kPa, 60kPa
Application area
The stainless membrane box pressure table
The configuration is confirmed by medium, measurement mission and installation environment, combined with technical information on the stainless steel sheet pressure table. The technical sections are available in the complete description.
- 01
Boiler/burner. Boiler chamber negative pressure monitoring, wind pressure. -0.4 ~ 0 、 0 ~ 2.5kPa
- 02
HVAC • Wind pipe static, filter pressure differential indicator . 0~1.6/2.5kPa
- 03
Gas system Micro-pressures, motorizing 0~6/10kPa
- 04
Ventilating dust removal . Wind wind pressure, dust removal resistance 0~4~16kPa
Selection Guide
The stainless membrane box pressure sheet.
Overpressure protection comes first. Capsule gauges have limited overpressure tolerance. Select the next range up for fluctuating conditions and fit a snubber or pressure limiter if needed. Example: furnace draft is normally −200 Pa and can reach −600 Pa. Select −1.6 to 0 kPa or a compound range of −2 to +2 kPa, with the operating point at about 12%–37% of full scale and an overpressure margin. YEF - 100 Z T Q - B: options (damping, zero adjustment, etc.), axial connection (Z; omit for radial), and dial diameter (60/100/150/160).

Support for stainless membrane box pressure table selection
Provide survey missions, media and installation conditions and obtain product configuration advice.
Contact us