A oxaba flow meterClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
FLUME-AN-100
A oxaba flow meter
A oxaba flow meter, average skin hosting, low pressure, wide range
01
Classification: Aoxaba flow meter
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | FLUME-AN-100 |
|---|---|
| Nominal pipe size | DN50~DN2000 |
| Measurement principle | Differential pressure flow (hot-faced chorus multiple-plug, Differential pressure transmitter flow calculated by the Bernoulian equation) |
| Measured medium | Liquid, gaseous, saturated vapour / superheated vapour |
| Accuracy class | ±1.0% (optional ±1.5%) |
| Repeatability | ±0.1% |
| Turndown ratio | 10:1 |
| Process medium temperature | -40~+450℃ |
| Ambient temperature | -25~+55℃ |
| Operating pressure | 1.0MPa、1.6MPa、2.5MPa、4.0MPa、6.3MPa |
| Sensor material | 304 stainless steel / 316L Stainless steel |
| Sensor cross section | Scrambled double cavity (Diamond), high pressure side 4 hole, low pressure side 4 hole multiple pressure |
| Mounting | Online opening Insertion (enabled with pressurized opening) |
| Straight pipe length requirements | 7D, 3D |
| Connection | Flanged connection, Threaded connection, online plug-in |
| Differential pressure transmitter | Capable / diffused silicon / monocrystalline silicon (4–20mA + HART) |
| Display type | Live LCD instant moment/ Totalized flow Display |
| Output signal | (4–20) mA, HART, RS485 (Modbus), Pulse |
| Power supply | 24V DC、220V AC |
| Explosion protection marking | Ex ia IIC T4 (intrinsically safe), Ex d IIC T6 (Flameproof) |
| Ingress protection | IP65 (optional IP67) |
| Electrical connection | M20×1.5 |
| Pressure loss | ≤0.6× differential pressure (small loss of permanent pressure, about 5%–10%) |
Product selection
FLUME-AN-100| Code | Nominal size (mm) | Measurement range (m³/h) |
|---|---|---|
| 50 | DN50 | 3.53~35.34 |
| 65 | DN65 | 5.97~59.73 |
| 80 | DN80 | 9.05~90.48 |
| 100 | DN100 | 14.14~141.37 |
| 125 | DN125 | 22.09~220.89 |
| 150 | DN150 | 31.81~318.09 |
| 200 | DN200 | 56.55~565.49 |
| 250 | DN250 | 88.36~883.57 |
| 300 | DN300 | 127.23~1272.35 |
| 400 | DN400 | 226.19~2261.95 |
| 500 | DN500 | 353.43~3534.29 |
| 600 | DN600 | 508.94~5089.38 |
| 800 | DN800 | 904.78~9047.79 |
| 1000 | DN1000 | 1413.72~14137.17 |
| 1200 | DN1200 | 2035.75~20357.52 |
| 1400 | DN1400 | 2770.88~27708.85 |
| 1600 | DN1600 | 3619.11~36191.15 |
| 2000 | DN2000 | 5654.87~56548.67 |
| Code | Pressure rating |
|---|---|
| P1 | 1.0 MPa |
| P2 | 1.6 MPa |
| P3 | 2.5 MPa |
| P4 | 4.0 MPa |
| P5 | 6.3 MPa |
| Code | Sensor material |
|---|---|
| B1 | 304 Stainless steel |
| B2 | 316L Stainless steel |
| Code | Pressure tapping method |
|---|---|
| K1 | More than enough pressure. |
| K2 | Single Point Counterpressure |
| Code | Accuracy class |
|---|---|
| E1 | ±1.0% |
| E2 | ±1.5% |
| Code | Process medium temperature |
|---|---|
| T1 | -40~200℃ |
| T2 | ≤350℃ |
| T3 | ≤450℃ |
| Code | Connection |
|---|---|
| C1 | Flanged connection |
| C2 | Threaded connection |
| C3 | Online Plugin |
| Code | Differential pressure transmitter |
|---|---|
| S1 | Capacitive |
| S2 | Diffused silicon |
| S3 | Monocrystalline silicon |
| Code | Power supply |
|---|---|
| D1 | 24V DC |
| D2 | 220V AC |
| Code | Signal output |
|---|---|
| F1 | (4~20)mA |
| F2 | (4~20)mA + HART |
| F3 | RS485(Modbus) |
| Code | Explosion protection marking |
|---|---|
| U0 | Non-Ex |
| U1 | Ex ia IIC T4 (Intrinsically safe) |
| U2 | Ex d IIC T6 (Flameproof) |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us