View selection tables ↓| Model | FLUME-DP-100 |
|---|---|
| Nominal pipe size | DN50~DN1000 |
| Measurement principle | Differential pressure (Standard perforated plate throttle with Differential pressure transmitter, calculated by the Bernoulian equation) |
| Measured medium | Liquid, gaseous, saturated vapour / superheated vapour |
| Accuracy class | ±1.0% (optional ±1.5%) |
| Turndown ratio | 3:1 (optional 5:1) |
| Process medium temperature | -40~+450℃ |
| Ambient temperature | -25~+55℃ |
| Operating pressure | 1.6MPa、2.5MPa、4.0MPa、6.3MPa |
| Primary element material | 304 stainless steel / 316L Stainless steel |
| Pressure tapping method | Angular extraction pressure, flange pressure, D-D/2 pressure |
| Straight pipe length requirements | Former 10D, later 5D (without pressures) |
| Connection | Flanged connection GB/T 9119, pairs, welding |
| Differential pressure transmitter | Capable / diffused silicon / monocrystalline silicon (4–20mA + HART) |
| Display type | Live LCD instant moment/ Totalized flow Display |
| Output signal | (4–20) mA, HART, RS485 (Modbus), Pulse |
| Power supply | 24V DC、220V AC |
| Explosion protection marking | Ex ia IIC T4 (intrinsically safe), Ex d IIC T6 (Flameproof) |
| Ingress protection | IP65 (optional IP67) |
| Electrical connection | M20×1.5 |
| Pressure loss | Depending on the β margin and Differential pressure (restrictible flow hole panels to reduce loss) |
Product selection
FLUME-DP-100| Code | Nominal size (mm) | Measurement range (m³/h) |
|---|---|---|
| 50 | DN50 | 10.00~30.00 |
| 65 | DN65 | 15.00~50.00 |
| 80 | DN80 | 25.00~80.00 |
| 100 | DN100 | 40.00~120.00 |
| 125 | DN125 | 60.00~180.00 |
| 150 | DN150 | 80.00~250.00 |
| 200 | DN200 | 150.00~450.00 |
| 250 | DN250 | 250.00~700.00 |
| 300 | DN300 | 350.00~1000.00 |
| 400 | DN400 | 600.00~1800.00 |
| 500 | DN500 | 1000.00~2800.00 |
| 600 | DN600 | 1400.00~4000.00 |
| 800 | DN800 | 2500.00~7000.00 |
| 1000 | DN1000 | 4000.00~11000.00 |
| Code | Pressure rating |
|---|---|
| P1 | 1.6 MPa |
| P2 | 2.5 MPa |
| P3 | 4.0 MPa |
| P4 | 6.3 MPa |
| Code | Primary element material |
|---|---|
| B1 | 304 Stainless steel |
| B2 | 316L Stainless steel |
| Code | Pressure tapping method |
|---|---|
| K1 | Angle extraction pressure. |
| K2 | Flange pressure |
| K3 | D-D/2 pressure |
| Code | Accuracy class |
|---|---|
| E1 | ±1.0% |
| E2 | ±1.5% |
| Code | Process medium temperature |
|---|---|
| T1 | -40~200℃ |
| T2 | ≤350℃ |
| T3 | ≤450℃ |
| Code | Connection |
|---|---|
| C1 | Flanged connection GB/T 9119 |
| C2 | Link Connections |
| C3 | Weld Connection |
| Code | Differential pressure transmitter |
|---|---|
| S1 | Capacitive |
| S2 | Diffused silicon |
| S3 | Monocrystalline silicon |
| Code | Power supply |
|---|---|
| D1 | 24V DC |
| D2 | 220V AC |
| Code | Signal output |
|---|---|
| F1 | (4~20)mA |
| F2 | (4~20)mA + HART |
| F3 | RS485(Modbus) |
| Code | Explosion protection marking |
|---|---|
| U0 | Non-Ex |
| U1 | Ex ia IIC T4 (Intrinsically safe) |
| U2 | Ex d IIC T6 (Flameproof) |