Spin-in-vortex flow metersClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
FLUME-PR-100
Spin-in-vortex flow meters
Turbo flow meters, spin vortex principles, applicable to gas measurement
01
Classification: Spinning vortex flowometer
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | FLUME-PR-100 |
|---|---|
| Nominal pipe size | DN15~DN200 |
| Measurement principle | Rotation vortex (the vortex vortex movement frequency is proportional to flow, voltage crystal detection) |
| Measured medium | Gases such as natural gas, urban gas, liquefied petroleum gas, air, nitrogen, etc. |
| Accuracy class | 1.0 (optional 1.5) |
| Repeatability | ≤0.2% |
| Turndown ratio | 10:1 (optional 15:1) |
| Process medium temperature | -20–+60℃ (normal temperature) ≤80℃ (High-temperature type) |
| Ambient temperature | -25~+55℃ |
| Operating pressure | 1.6MPa、2.5MPa、4.0MPa、6.3MPa |
| Flow range | 1.5–4000 Nm³/h (press Nominal size) |
| Body material | 304 stainless steel / 316L Stainless steel |
| Vortex shedder | 316L Stainless steel (integrated processing) |
| Test Method | Voltage crystals / double-voltage crystals / pressure variance |
| Connection | Flanged connection GB/T 9119, Threaded connection |
| Temperature and pressure compensation | Inline thermostat sensors, autotransformation of physical volume flows |
| Display type | Field LCD Display profile flow, total, pressure, temperature |
| Output signal | (4–20) mA, HART, RS485 (Modbus), Pulse |
| Power supply | 24V DC, 220V AC, 3.6V |
| Explosion protection marking | Ex ia IIC T4 (intrinsically safe), Ex d IIC T6 (Flameproof) |
| Ingress protection | IP65 (optional IP67) |
| Electrical connection | M20×1.5 |
| Pressure loss | ≤0.02 MPa (under rated traffic) |
Product selection
FLUME-PR-100| Code | Nominal size (mm) | Measurement range (m³/h) |
|---|---|---|
| 15 | DN15 | 1.50~15.00 |
| 20 | DN20 | 3.00~30.00 |
| 25 | DN25 | 5.00~50.00 |
| 32 | DN32 | 8.00~80.00 |
| 40 | DN40 | 12.00~120.00 |
| 50 | DN50 | 20.00~200.00 |
| 65 | DN65 | 30.00~300.00 |
| 80 | DN80 | 50.00~500.00 |
| 100 | DN100 | 80.00~800.00 |
| 150 | DN150 | 200.00~2000.00 |
| 200 | DN200 | 400.00~4000.00 |
| Code | Pressure rating |
|---|---|
| P1 | 1.6 MPa |
| P2 | 2.5 MPa |
| P3 | 4.0 MPa |
| P4 | 6.3 MPa |
| Code | Body material |
|---|---|
| B1 | 304 Stainless steel |
| B2 | 316L Stainless steel |
| Code | Test Method |
|---|---|
| K1 | Voltage crystals |
| K2 | Double-pressure crystal |
| K3 | Pressure variance |
| Code | Accuracy class |
|---|---|
| E1 | Level 1.0 |
| E2 | Level 1.5 |
| Code | Process medium temperature |
|---|---|
| T1 | -20–60℃ (attractive) |
| T2 | ≤80℃ (High-temperature type) |
| Code | Connection |
|---|---|
| C1 | Flanged connection GB/T 9119 |
| C2 | Threaded connection |
| Code | Temperature and pressure compensation |
|---|---|
| S1 | None (work volume flow only) |
| S2 | Internal Temperature and pressure compensation |
| S3 | External temperature Transmitter compensation |
| Code | Power supply |
|---|---|
| D1 | 24V DC |
| D2 | 220V AC |
| D3 | 3.6V lithium batteries |
| Code | Signal output |
|---|---|
| F1 | (4~20)mA |
| F2 | (4~20)mA + HART |
| F3 | RS485(Modbus) |
| F4 | Pulse out |
| Code | Explosion protection marking |
|---|---|
| U0 | Non-Ex |
| U1 | Ex ia IIC T4 (Intrinsically safe) |
| U2 | Ex d IIC T6 (Flameproof) |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us