Cone flow countClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
FLUME-VC-100
Cone flow count
V-cone flow meters, V-cone-savings, self-remediation, blockage, low pressure
01
Classification: Cone flow count
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | FLUME-VC-100 |
|---|---|
| Nominal pipe size | DN25~DN2000 |
| Measurement principle | Differential pressure (V cone current, cone and tube wall forming circular Differential pressure transmitter) |
| Measured medium | Liquid, gaseous, saturated vapour / superheated vapour (containing dust, desolate, high viscosity media) |
| Accuracy class | ±0.5% (optional ±1.0%) |
| Repeatability | ±0.1% |
| Turndown ratio | 10:1 (extensible to 15:1) |
| Process medium temperature | -40~+450℃ |
| Ambient temperature | -25~+55℃ |
| Operating pressure | 1.0MPa、1.6MPa、2.5MPa、4.0MPa、6.3MPa |
| Cone material | 304 stainless steel / 316L Stainless steel |
| Cone Structure | V cone arms, cone angle 45°, throttle surface self-cleaning, not easy to build |
| Pressure tapping method | High pressure side cones, low pressure side cones centre. |
| Mounting | Installation of horizontal or vertical conduits (bottom-up medium at vertically) |
| Straight pipe length requirements | Former 3D, later 1D (V cone Straight pipe length requirements low) |
| Connection | Flanged connection, connects, welds. |
| Differential pressure transmitter | Capable / diffused silicon / monocrystalline silicon (4–20mA + HART) |
| Display type | Live LCD instant moment/ Totalized flow Display |
| Output signal | (4–20) mA, HART, RS485 (Modbus), Pulse |
| Power supply | 24V DC、220V AC |
| Explosion protection marking | Ex ia IIC T4 (intrinsically safe), Ex d IIC T6 (Flameproof) |
| Ingress protection | IP65 (optional IP67) |
| Electrical connection | M20×1.5 |
| Pressure loss | ≤0.3× differential pressure (permanent pressure loss about 1/3) |
Product selection
FLUME-VC-100| Code | Nominal size (mm) | Measurement range (m³/h) |
|---|---|---|
| 25 | DN25 | 0.88~8.84 |
| 40 | DN40 | 2.26~22.62 |
| 50 | DN50 | 3.53~35.34 |
| 65 | DN65 | 5.97~59.73 |
| 80 | DN80 | 9.05~90.48 |
| 100 | DN100 | 14.14~141.37 |
| 125 | DN125 | 22.09~220.89 |
| 150 | DN150 | 31.81~318.09 |
| 200 | DN200 | 56.55~565.49 |
| 250 | DN250 | 88.36~883.57 |
| 300 | DN300 | 127.23~1272.35 |
| 400 | DN400 | 226.19~2261.95 |
| 500 | DN500 | 353.43~3534.29 |
| 600 | DN600 | 508.94~5089.38 |
| 800 | DN800 | 904.78~9047.79 |
| 1000 | DN1000 | 1413.72~14137.17 |
| 1400 | DN1400 | 2770.88~27708.85 |
| 2000 | DN2000 | 5654.87~56548.67 |
| Code | Pressure rating |
|---|---|
| P1 | 1.0 MPa |
| P2 | 1.6 MPa |
| P3 | 2.5 MPa |
| P4 | 4.0 MPa |
| P5 | 6.3 MPa |
| Code | Cone material |
|---|---|
| B1 | 304 Stainless steel |
| B2 | 316L Stainless steel |
| Code | Pressure tapping method |
|---|---|
| K1 | Conesian/Possive pressure |
| K2 | Flange pressure |
| Code | Accuracy class |
|---|---|
| E1 | ±0.5% |
| E2 | ±1.0% |
| Code | Process medium temperature |
|---|---|
| T1 | -40~200℃ |
| T2 | ≤350℃ |
| T3 | ≤450℃ |
| Code | Connection |
|---|---|
| C1 | Flanged connection |
| C2 | Link Connections |
| C3 | Weld Connection |
| Code | Differential pressure transmitter |
|---|---|
| S1 | Capacitive |
| S2 | Diffused silicon |
| S3 | Monocrystalline silicon |
| Code | Power supply |
|---|---|
| D1 | 24V DC |
| D2 | 220V AC |
| Code | Signal output |
|---|---|
| F1 | (4~20)mA |
| F2 | (4~20)mA + HART |
| F3 | RS485(Modbus) |
| Code | Explosion protection marking |
|---|---|
| U0 | Non-Ex |
| U1 | Ex ia IIC T4 (Intrinsically safe) |
| U2 | Ex d IIC T6 (Flameproof) |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us