HoldingClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

FLUME-VX-100

Turbo Street Flow Count ..

Turbo-flow meters, portable configuration. Carmen Turbo-Street principles, suitable for steam, gas and liquid.

01

Classification: Turbo Street Flow Count

02

Structure form: held

Back to Turbo Street Flow Count.

TECHNICAL SPECIFICATIONS

Technical specifications

FLUME-VX-100

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelFLUME-VX-100
Nominal pipe sizeDN15~DN300
Measurement principleCarmen Turbo Street (voltage crystal detection, no moving parts)
Measured mediumLiquid, gaseous, saturated vapour / superheated vapour
Reference medium for flow rangesLiquids: water (20℃); gas: profile air (0℃, 101.325kPa); vapour: 0.8MPa saturated vapour actual density or pressure deviation, depending on the condition, with temperature, pressure, density when ordered
Accuracy class1.0 (liquid), 1.5 (gas, steam)
Repeatability±0.2%
Turndown ratio10:1 (optional 20:1)
Process medium temperature-40–+150℃ (normal temperature) ≤250℃ (moderate) ≤350℃ (High-temperature type with dispersed heat)
Temperature and pressure compensationW1 Internal Pt1000 Temperature + Pressure sensor integration, automatic conversion of volume or mass flow W2 External split, with independence. temperature and pressure compensation transmitter post-compensation system accuracy ±1.0% (gas, steam)
Ambient temperature-25~+55℃
Operating pressure1.6MPa、2.5MPa、4.0MPa
Flow velocity rangeLiquid 0.5–8m/s gas 5–50m/s vapour 5–70m/s
Body material304 stainless steel / 316L Stainless steel
Probe material316L stainless steel Hastelloy C, titanium
ConnectionStaple (Systems installed with pipe Flange)
Display typeLive LCD instant moment/ Totalized flow Display
Output signal(4–20) mA, HART, RS485 (Modbus), Pulse
Power supply24V DC, 220V AC, 3.6V
Explosion protection markingEx ia IIC T4 (intrinsically safe), Ex d IIC T6 (Flameproof)
Ingress protectionIP65 (optional IP67)
Electrical connectionM20×1.5
Pressure loss≤25 kPa

Product selection

FLUME-VX-100
Size and flow ranges
CodeNominal size (mm)Liquid Range (m³/h)Gas Range (Nm³/h)Steam Range (kg/h)
15DN150.60~6.003~3013~185
20DN201.00~10.005~5324~329
25DN251.60~16.008~8237~515
32DN322.50~25.0013~13560~843
40DN404.00~40.0021~21194~1317
50DN506.00~60.0033~329147~2058
65DN6510.00~100.0056~557248~3479
80DN8015.00~150.0084~843376~5269
100DN10025.00~250.00132~1317588~8233
125DN12540.00~400.00206~2058919~12865
150DN15060.00~600.00296~29641323~18525
200DN200100.00~1000.00527~52692352~32934
250DN250150.00~1500.00823~82323676~51459
300DN300200.00~2000.001185~118545293~74101
Measured medium
CodeMeasured medium
M1Liquids (water, oil, acid solution, etc.)
M2Gases (air, nitrogen, gas, compressed air, etc.)
M3Vapour (saturated steam, overheated steam)
Pressure rating
CodePressure rating
P21.6 MPa
P32.5 MPa
P44.0 MPa
Body material
CodeBody material
B1304 Stainless steel
B2316L Stainless steel
Probe material
CodeProbe material
K1316L Stainless steel
K2Hastelloy C
K3Titanium
Accuracy class
CodeAccuracy class
E1Level 1.0
E2Level 1.5
Process medium temperature
CodeProcess medium temperature
T1-40–150℃ (attractive)
T2≤250℃ (medium temperature)
T3≤350℃ (High-temperature type with a radiator)
Temperature and pressure compensation
CodeTemperature and pressure compensation
W0None (work volume flow only)
W1Inline Temperature and pressure compensation (integrated, gas/vapour)
W2Outer Temperature and pressure compensation (division)
Power supply
CodePower supply
D124V DC
D2220V AC
D33.6V lithium batteries
Signal output
CodeSignal output
F1(4~20)mA
F2(4~20)mA + HART
F3RS485(Modbus)
F4Pulse out
Explosion protection marking
CodeExplosion protection marking
U0Non-Ex
U1Ex ia IIC T4 (Intrinsically safe)
U2Ex d IIC T6 (Flameproof)

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
FLUME-VX-100 Wafer Vortex Flowmeter