Wedge flow metersClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
FLUME-WG-100
Wedge flow meters
Wedge flow meters, wedge styling, application of high viscosity, particle-containing media
01
Classification: Wedge flow meters
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | FLUME-WG-100 |
|---|---|
| Nominal pipe size | DN25~DN1000 |
| Measurement principle | Differential pressure (weed styling, V wedges and tube walls make a gradual expansion of the stream, with Differential pressure transmitter) |
| Measured medium | High viscosity liquids, slurry, solid particle media, gas, steam |
| Accuracy class | ±0.5% (optional ±1.0%) |
| Repeatability | ±0.1% |
| Turndown ratio | 10:1 |
| Process medium temperature | -40~+450℃ |
| Ambient temperature | -25~+55℃ |
| Operating pressure | 1.0MPa、1.6MPa、2.5MPa、4.0MPa、6.3MPa |
| Wedge element material | 304 stainless steel / 316L Stainless steel |
| Wedge ratio | H/D = 0.3, 0.4, 0.5 (by traffic with Differential pressure Optional) |
| Pressure tapping method | Upstream high pressure side / lower pressure side downstream, Pressure tap is not easily blocked |
| Structural characteristics | No dead zone, self-cleaning stream, applicable to mulch, crystallized, fibre-containing media |
| Mounting | Installation of horizontal or vertical conduits (bottom-up medium at vertically) |
| Straight pipe length requirements | 5D, 3D |
| Connection | Flanged connection, connects, welds. |
| Differential pressure transmitter | Capable / diffused silicon / monocrystalline silicon (4–20mA + HART) |
| Display type | Live LCD instant moment/ Totalized flow Display |
| Output signal | (4–20) mA, HART, RS485 (Modbus), Pulse |
| Power supply | 24V DC、220V AC |
| Explosion protection marking | Ex ia IIC T4 (intrinsically safe), Ex d IIC T6 (Flameproof) |
| Ingress protection | IP65 (optional IP67) |
| Electrical connection | M20×1.5 |
| Pressure loss | ≤0.5× Differential pressure (Permanent pressure loss below hole plate) |
Product selection
FLUME-WG-100| Code | Nominal size (mm) | Measurement range (m³/h) |
|---|---|---|
| 25 | DN25 | 0.88~8.84 |
| 40 | DN40 | 2.26~22.62 |
| 50 | DN50 | 3.53~35.34 |
| 65 | DN65 | 5.97~59.73 |
| 80 | DN80 | 9.05~90.48 |
| 100 | DN100 | 14.14~141.37 |
| 125 | DN125 | 22.09~220.89 |
| 150 | DN150 | 31.81~318.09 |
| 200 | DN200 | 56.55~565.49 |
| 250 | DN250 | 88.36~883.57 |
| 300 | DN300 | 127.23~1272.35 |
| 400 | DN400 | 226.19~2261.95 |
| 500 | DN500 | 353.43~3534.29 |
| 600 | DN600 | 508.94~5089.38 |
| 800 | DN800 | 904.78~9047.79 |
| 1000 | DN1000 | 1413.72~14137.17 |
| Code | Pressure rating |
|---|---|
| P1 | 1.0 MPa |
| P2 | 1.6 MPa |
| P3 | 2.5 MPa |
| P4 | 4.0 MPa |
| P5 | 6.3 MPa |
| Code | Wedge element material |
|---|---|
| B1 | 304 Stainless steel |
| B2 | 316L Stainless steel |
| Code | Wedge ratio |
|---|---|
| W1 | H/D=0.3 |
| W2 | H/D=0.4 |
| W3 | H/D=0.5 |
| Code | Accuracy class |
|---|---|
| E1 | ±0.5% |
| E2 | ±1.0% |
| Code | Process medium temperature |
|---|---|
| T1 | -40~200℃ |
| T2 | ≤350℃ |
| T3 | ≤450℃ |
| Code | Connection |
|---|---|
| C1 | Flanged connection |
| C2 | Link Connections |
| C3 | Weld Connection |
| Code | Differential pressure transmitter |
|---|---|
| S1 | Capacitive |
| S2 | Diffused silicon |
| S3 | Monocrystalline silicon |
| Code | Power supply |
|---|---|
| D1 | 24V DC |
| D2 | 220V AC |
| Code | Signal output |
|---|---|
| F1 | (4~20)mA |
| F2 | (4~20)mA + HART |
| F3 | RS485(Modbus) |
| Code | Explosion protection marking |
|---|---|
| U0 | Non-Ex |
| U1 | Ex ia IIC T4 (Intrinsically safe) |
| U2 | Ex d IIC T6 (Flameproof) |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.