Smart differential transmitterClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
PRETRAN-DP-150
Smart differential transmitter
Smart differential transmitter, differential measurement, usable for fluids and flow
01
Classification: Smart differential transmitter
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | PRETRAN-DP-150 |
|---|---|
| Measurement principle | Monocrystalline silicon piezoresistive / Capable Sensor + Digital signal processing (smart) |
| Measurement type | Differential pressure (D) / flow with an orifice plate (Q) / level (L) |
| Measurement range | Ranges from 0–100 Pa to 0–6 MPa; adjustable 100:1 turndown |
| Accuracy class | ±0.075% / ±0.1% / ±0.2% (Optional) |
| Maximum static pressure | 10MPa / 25MPa (Optional) |
| Output signal | 4–20mA (DC) + HART / RS485 (MODBUS) Optional |
| Power supply | 12–36VDC (standard 24VDC) |
| Load capacity | (Supply voltage − 12 V) / 0.02 A, up to 1.2 kΩ |
| Sensor capsule | 316L (standard), Hastelloy C276, tantalum (Optional) |
| Construction | Direct-mount three-valve manifold or dual remote seals (1–15 m capillaries) |
| Process connection | 1/2NPT (F) three-valve manifold interface / DN25–DN80 flange (PN1.0–4.0) |
| Display type | 4 bit LCD local Display (percentage/project volume) rotates the watch header |
| Damping time | 0–32s Configurable |
| Stability | ±0.1% /year |
| Process medium temperature | -40–+120℃ (dual remote seals to +350℃) |
| Ambient temperature | -40~+85℃ |
| Ingress and explosion protection | IP66/IP67; Ex d II C T6 Gb / Ex ia II C T4 Ga (Optional) |
| Fill fluid | Silicone oil (standard) / low-temperature silicone oil / food-grade glycerin |
| Applicable standards | GB/T 17614 / IEC 61010 / HART 7 |
| Suitable media | Measurement of gas, liquid, steam differential pressure / flow/ level (compatible 316L) |
Product selection
PRETRAN-DP-150| Code | Construction |
|---|---|
| S1 | Three-valve manifold straight chain (Standard) |
| S2 | Double flat Flange long-distance |
| S3 | Double-plug Flange long-distance (high temperature/slurry) |
| Code | Range options (kPa) |
|---|---|
| R1 | 0–100Pa–0–1kPa (micro Differential pressure) |
| R2 | 0~1kPa~0~10kPa |
| R3 | 0~10kPa~0~100kPa |
| R4 | 0~100kPa~0~6000kPa(6MPa) |
| Code | Accuracy class |
|---|---|
| E1 | ±0.2% |
| E2 | ±0.1% |
| E3 | ±0.075% |
| Code | Maximum static pressure |
|---|---|
| P1 | 10MPa |
| P2 | 25MPa |
| Code | Output signal |
|---|---|
| O1 | 4~20mA + HART |
| O2 | 4~20mA + RS485(MODBUS-RTU) |
| Code | Sensor capsule / flange material |
|---|---|
| M1 | 316L Stainless steel |
| M2 | Hastelloy C276 |
| M3 | Tantalum Ta (strong corrosive) |
| Code | Capillary length (remote seal) |
|---|---|
| C1 | Straight chain (no Capillary) |
| C2 | 2m (Standard) |
| C3 | 5m |
| C4 | 10m / 15m (Specify when ordering) |
| Code | Explosion protection marking |
|---|---|
| X1 | Non-Ex |
| X2 | Flameproof Ex d II C T6 Gb |
| X3 | Intrinsically safe Ex ia II C T4 Ga |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us