TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | PRETRAN-PR-100 |
|---|---|
| Measurement principle | Monocrystalline silicon piezoresistive / Capable Sensor + Digital signal processing (smart) |
| Measurement type | Gauge pressure (G) / absolute pressure (A) / Vacuum (complex) |
| Measurement range | 0–100Pa to 0–60MPa (turndown ratio 100:1 Adjustable) |
| Accuracy class | ±0.075% / ±0.1% / ±0.2% (Optional) |
| Output signal | 4–20mA (DC) + HART protocol/ RS485 (MODBUS)/ 0–10V Optional |
| Power supply | 12–36VDC (standard 24VDC) |
| Load capacity | (Supply voltage − 12 V) / 0.02 A, up to 1.2 kΩ |
| Sensor capsule | 316L (standard), Hastelloy C276, tantalum (Optional) |
| Process connection | M20×1.5 / G1/2 / 1/2NPT / Flange (single flat/single plug) |
| Display type | 4 bit LCD local Display (percentage/project volume) rotates the watch header |
| Damping time | 0–32s Configurable |
| Stability | ±0.1% /year (10 annual calibration cycle Optional) |
| Process medium temperature | -40–+120℃ (high-temperature type to +350℃ with barbed tube/distant Diaphragm capsule) |
| Ambient temperature | -40~+85℃ |
| Ingress and explosion protection | IP66/IP67; Ex d II C T6 Gb / Ex ia II C T4 Ga (Optional) |
| Communication and diagnostics | HART Handheld/Debug software Configuration; self-diagnosis Range Alarm |
| Electrical connection | 2×M20×1.5 / 1/2NPT-F (Cable interface) |
| Applicable standards | GB/T 17614 / IEC 61010 / HART 7 |
| Suitable media | Liquid, gas, vapour pressure/ absolute pressure / vacuum measurements (compatible 316L) |
Product selection
PRETRAN-PR-100| Code | Measurement type |
|---|---|
| T1 | Gauge pressure (G) |
| T2 | Absolute pressure (A) |
| T3 | Vacuum /complex(-100kPa–0–x) |
| Code | Range options (MPa) |
|---|---|
| R1 | 0–100Pa–0–6kPa (micropressure) |
| R2 | 0~6kPa~0~60kPa |
| R3 | 0~60kPa~0~600kPa |
| R4 | 0~0.6MPa~0~6MPa |
| R5 | 0~6MPa~0~60MPa |
| Code | Accuracy class |
|---|---|
| E1 | ±0.2% |
| E2 | ±0.1% |
| E3 | ±0.075% |
| Code | Output signal |
|---|---|
| O1 | 4~20mA + HART |
| O2 | 4~20mA + RS485(MODBUS-RTU) |
| O3 | 0~10V |
| Code | Sensor capsule materials |
|---|---|
| M1 | 316L Stainless steel |
| M2 | Hastelloy C276 |
| M3 | Tantalum Ta (strong corrosive) |
| Code | Process connection |
|---|---|
| J1 | M20×1.5 Male thread |
| J2 | G1/2 / 1/2NPT |
| J3 | Single Flange (tele-sealed) |
| J4 | Single plug Flange (high temperature/slurry) |
| Code | Display and adjustment |
|---|---|
| L1 | No display (Standard header) |
| L2 | 4 LCD Display |
| L3 | LCD + local magnetic pen school |
| Code | Explosion protection marking |
|---|---|
| X1 | Non-Ex (Intrinsically safe / Flameproof Optional) |
| X2 | Flameproof Ex d II C T6 Gb |
| X3 | Intrinsically safe Ex ia II C T4 Ga |