Single-crystal silicon pressure transmitterClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
PRETRAN-SIL-100
Single-crystal silicon pressure transmitter
Single-crystal silicon pressure transmitter, single-crystal silicon sensor, long-term stability.
01
Classification: Single-crystal silicon pressure transmitter
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | PRETRAN-SIL-100 |
|---|---|
| Measurement principle | Monocrystalline silicon piezoresistive / resonant + Digital signal processing (smart) |
| Measurement type | Gauge pressure (G) / absolute pressure (A) / Vacuum (complex) |
| Measurement range | 0–100Pa to 0–60MPa (turndown ratio 100:1 Adjustable) |
| Accuracy class | ±0.075% / ±0.1% / ±0.2% (Optional) |
| Overload capacity | 2 multiple Full scale (in a moment) |
| Output signal | 4–20mA (DC) + HART / RS485 (MODBUS) / 0–10V Optional |
| Power supply | 12–36VDC (standard 24VDC) |
| Load capacity | (Supply voltage − 12 V) / 0.02 A, up to 1.2 kΩ |
| Sensor capsule | Monocrystalline silicon sensor with 316L isolation diaphragm (optional Hastelloy C276 or tantalum) |
| Process connection | M20×1.5 / G1/2 / 1/2NPT / Single/Single Flange (Apogee Optional) |
| Display type | 5-digit local LCD showing percentage or engineering units, with rotatable display and magnetic adjustment through the cover |
| Damping time | 0–32s Configurable |
| Stability | ±0.1% per year, with an optional five-year calibration interval |
| Process medium temperature | -40–+120℃ (high-temperature type to +350℃ with bulk heat/distant Diaphragm capsule) |
| Ambient temperature | -40~+85℃ |
| Temperature compensation | Digital temperature compensation throughout the −10 to +60 °C range |
| Ingress and explosion protection | IP66/IP67; Ex d II C T6 Gb / Ex ia II C T4 Ga (Optional) |
| Electrical connection | 2×M20×1.5 / 1/2NPT-F (Cable interface) |
| Applicable standards | GB/T 17614 / IEC 61010 / HART 7 / SIL2 (hardware redundancy Optional) |
| Suitable media | Liquids, gases, vapours; high accuracy process control, measurable pressure measurements (compatible 316L) |
Product selection
PRETRAN-SIL-100| Code | Measurement type |
|---|---|
| T1 | Gauge pressure (G) |
| T2 | Absolute pressure (A) |
| T3 | Vacuum /complex(-100kPa–0–x) |
| Code | Range options |
|---|---|
| R1 | 0–100Pa–0–6kPa (micropressure) |
| R2 | 0~6kPa~0~60kPa |
| R3 | 0~60kPa~0~600kPa |
| R4 | 0~0.6MPa~0~6MPa |
| R5 | 0~6MPa~0~60MPa |
| Code | Accuracy class |
|---|---|
| E1 | ±0.2% |
| E2 | ±0.1% |
| E3 | ±0.075% |
| Code | Output signal |
|---|---|
| O1 | 4~20mA + HART |
| O2 | 4~20mA + RS485(MODBUS-RTU) |
| O3 | 0~10V |
| Code | Isolation diaphragm material |
|---|---|
| M1 | 316L Stainless steel |
| M2 | Hastelloy C276 |
| M3 | Tantalum Ta (strong corrosive) |
| Code | Process connection |
|---|---|
| J1 | M20×1.5 Male thread |
| J2 | G1/2 / 1/2NPT |
| J3 | Single Flange (tele-sealed) |
| J4 | Single plug Flange (high temperature/slurry) |
| Code | Display and adjustment |
|---|---|
| L1 | No display (Standard header) |
| L2 | 5 LCD Display |
| L3 | LCD + Magnetic pens are off the grid. |
| Code | Explosion protection marking |
|---|---|
| X1 | Non-Ex (Intrinsically safe / Flameproof Optional) |
| X2 | Flameproof Ex d II C T6 Gb |
| X3 | Intrinsically safe Ex ia II C T4 Ga |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us