TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | PRETRAN-SIL-150 |
|---|---|
| Measurement principle | Monocrystalline silicon piezoresistive or resonant differential pressure sensor with digital signal processing |
| Measurement type | Differential pressure (D) / flow with an orifice plate (Q) / level (L) |
| Measurement range | Ranges from 0–100 Pa to 0–6 MPa; adjustable 100:1 turndown |
| Accuracy class | ±0.075% / ±0.1% / ±0.2% (Optional) |
| Maximum static pressure | 10MPa / 25MPa (Optional) |
| Overload capacity | One-way static pressure protection: 14 MPa in the forward direction for the 25 MPa static pressure version |
| Output signal | 4–20mA (DC) + HART / RS485 (MODBUS) Optional |
| Power supply | 12–36VDC (standard 24VDC) |
| Load capacity | (Supply voltage − 12 V) / 0.02 A, up to 1.2 kΩ |
| Sensor capsule | Monocrystalline silicon sensor with 316L isolation diaphragm (optional Hastelloy C276 or tantalum) |
| Construction | Direct-mount three-valve manifold or dual remote seals (1–15 m capillaries) |
| Process connection | 1/2NPT (F) three-valve manifold interface / DN50–DN80 flange (PN1.0–4.0) |
| Display type | 5-digit local LCD showing percentage or engineering units, with rotatable display and magnetic adjustment through the cover |
| Damping time | 0–32s Configurable |
| Stability | ±0.1% per year, with an optional five-year calibration interval |
| Process medium temperature | -40–+120℃ (dual remote seals to +350℃) |
| Ambient temperature | -40~+85℃ |
| Temperature compensation | Digital temperature compensation throughout the −10 to +60 °C range |
| Ingress and explosion protection | IP66/IP67; Ex d II C T6 Gb / Ex ia II C T4 Ga (Optional) |
| Fill fluid | Silicone oil (standard) / low-temperature silicone oil / food-grade glycerin |
| Applicable standards | GB/T 17614 / IEC 61010 / HART 7 / SIL2 (hardware redundancy Optional) |
| Suitable media | Gas, liquid, steam differential pressure / flow/ level measurement, high accuracy measurement application (compatible 316L) |
Product selection
PRETRAN-SIL-150| Code | Construction |
|---|---|
| S1 | Three-valve manifold straight chain (Standard) |
| S2 | Double flat Flange long-distance |
| S3 | Double-plug Flange long-distance (high temperature/slurry) |
| Code | Range options (kPa) |
|---|---|
| R1 | 0–100Pa–0–1kPa (micro Differential pressure) |
| R2 | 0~1kPa~0~10kPa |
| R3 | 0~10kPa~0~100kPa |
| R4 | 0~100kPa~0~6000kPa(6MPa) |
| Code | Accuracy class |
|---|---|
| E1 | ±0.2% |
| E2 | ±0.1% |
| E3 | ±0.075% |
| Code | Maximum static pressure |
|---|---|
| P1 | 10MPa |
| P2 | 25MPa |
| Code | Output signal |
|---|---|
| O1 | 4~20mA + HART |
| O2 | 4~20mA + RS485(MODBUS-RTU) |
| Code | Isolation diaphragm / flange materials |
|---|---|
| M1 | 316L Stainless steel |
| M2 | Hastelloy C276 |
| M3 | Tantalum Ta (strong corrosive) |
| Code | Capillary length (remote seal) |
|---|---|
| C1 | Straight chain (no Capillary) |
| C2 | 2m (Standard) |
| C3 | 5m |
| C4 | 10m / 15m (Specify when ordering) |
| Code | Display and adjustment |
|---|---|
| L1 | No display (Standard header) |
| L2 | 5 LCD Display |
| L3 | LCD + Magnetic pens are off the grid. |
| Code | Explosion protection marking |
|---|---|
| X1 | Non-Ex |
| X2 | Flameproof Ex d II C T6 Gb |
| X3 | Intrinsically safe Ex ia II C T4 Ga |
Confirm specifications and ordering options