Heat resistance.Click on the picture to zoom in.
PRODUCT SPECIFICATIONS
TEMPSEN-RT-100
Heat resistance.
Heat resistance resistant, heated resistance resistant, high current speed conditions applied
01
Classification: Heat resistant resistance
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | TEMPSEN-RT-100 |
|---|---|
| Measurement principle | Pt100 resistance value changes linearly with temperature (R0=100Ω, α=0.00385), converted from variable/ Display instrument |
| Sensing element | Pt100 / Pt1000 (minus or circuit, A / B) |
| Measurement range | -200–+500℃ (Pt100 standard type); 0–+600℃ (High-temperature type) |
| Accuracy class | A Level ± (0.15+0.002 | t |) ℃ / B Level ± (0.30+0.005 | t |) ℃ |
| Wiring | Three-wire (Standard) / Four-wire (Optional, eliminate wire resistance) |
| Type Protection tube | 316L Tube + tungsten carbide (WC) Spraying / Whole-combusted Silicon Carbide (SiC) / Goonyu ceramics |
| Protection tube dimensions | φ16×L (insertion depth 150–1000mm optional) and grinding thickness 0.3–0.8mm |
| Wear resistance | Tungsten carbide micro-hardness of coating HV1100–1300, resistant to coal powder/slag erosion, with life expectancy of average 316L pipe 3–5 times |
| Process connection | M27×2 thread / G1 thread / DN40–DN50 flange (PN1.0–2.5) |
| Junction box | Waterproof cast iron /Aluminium Alloy junction box IP65 (Flameproof type Optional) |
| Response time | 0.5 ≤30s (protection tube φ16, medium flow speed ≥1m/s) |
| Insulation resistance | ≥100MΩ (500VDC, constant temperature) |
| Ambient temperature | -40–+80℃ (Junction box) |
| Operating pressure | Constant pressure –2.5MPa (Protection tube Stress pressure Insertion depth) |
| Output signal | Direct RTD signal (third line)/ Integration 4–20mA transport (optional, HART) |
| Explosion protection marking | Ex d II C T6 Gb flameproof (optional) / Ex ia II C T4 Ga Intrinsically safe (Optional) |
| Applicable standards | IEC 60751 / JB/T 8622 / GB/T 30429 |
| Suitable operating conditions | Coal powder pipes, fluidized bed boilers, ash-slag pipelines, coal grinder exports, cement kiln tails etc. |
| Product features | Grid-resistant layer integrated with base metallurgical and front-end ball/cone reinforced with Adjustable compression fitting for reconciliation Insertion depth |
Product selection
TEMPSEN-RT-100| Code | Sensing element / sensor type |
|---|---|
| P1 | Pt100 (A Class) |
| P2 | Pt100 (B Class) |
| P3 | Pt1000 (A Class) |
| Code | Measurement range |
|---|---|
| L1 | -200~+300℃ |
| L2 | -200–+500℃ (Standard) |
| L3 | 0–+600℃ (High-temperature type) |
| Code | Wear-resistant protection tube type |
|---|---|
| W1 | 316L + Tungsten carbide spray (general grinding) |
| W2 | The whole carbide silica SiC (strength punching) |
| W3 | Goonyu ceramic pipe (silver tolerance + erosion resistance) |
| Code | Insertion depth L |
|---|---|
| D1 | 150 / 200mm |
| D2 | 300 / 400mm |
| D3 | 500 / 750mm |
| D4 | 1000mm (Specify when ordering) |
| Code | Process connection |
|---|---|
| F1 | M27×2 Thread |
| F2 | G1 Thread / Adjustable compression fitting |
| F3 | DN40 / DN50 Flange |
| Code | Wiring / output |
|---|---|
| O1 | Three-wire RTD (Standard) |
| O2 | Four-wire RTD |
| O3 | Integration 4–20mA |
| Code | Junction box / explosion protection |
|---|---|
| X1 | Waterproof junction box IP65 (Non-Ex) |
| X2 | Flameproof Ex d II C T6 Gb |
| X3 | Intrinsically safe Ex ia II C T4 Ga |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us