- It's a heat resistance.Click on the picture to zoom in.
PRODUCT SPECIFICATIONS
TEMPSEN-RT-200
- It's a heat resistance.
♪ Thermal resistance in a suit, in a suit, softly bend ♪
01
Classification: Zip-based thermal resistance
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | TEMPSEN-RT-200 |
|---|---|
| Measurement principle | Pt100 resistance value changes linearly with temperature (R0=100Ω, α=0.00385), converted from variable/ Display instrument |
| Sensing element | Pt100 / Pt1000 (film or circuit, A / B level); Simplex, Duplex (redundant) Optional |
| Measurement range | -200–+600℃ (mineral-insulated Pt100 Standard type) |
| Accuracy class | A Level ± (0.15+0.002 | t |) ℃ / B Level ± (0.30+0.005 | t |) ℃ |
| Construction | Mineral-insulated Integration: stainless steel mineral-insulated core (φ3–φ8) + magnesium oxide insulation + metal shield, which can be bent into shape as a whole |
| Mineral-insulated core material | 304 / 316L / 321 stainless steel Mask, MgO insulation |
| Mineral-insulated probe OD | φ3, φ4, φ5, φ6, φ8 (Optional) |
| Insertion depth | 50 / 75 / 100 / 150 / 200 / 300 / 500 / 1000mm (can be customised for any length) |
| Minimum bend radius | ≥5× Mineral-insulated probe OD |
| Process connection | M8×1 / M12×1.5 / M20×1.5 / G½ Thread; Adjustable compression fitting, spring pressure close to the head |
| Junction box | Waterproof aluminium alloy/ stainless steel junction box IP65, or direct lead (naked/shield/ Circular connector) |
| Wiring | Three-wire (Standard) / Four-wire (Optional, eliminate wire resistance) / Two-line system |
| Response time | 0.5 ≤8s (φ6 mineral-insulated, medium flow speed ≥0.5m/s) |
| Insulation resistance | ≥100MΩ (500VDC, constant temperature) |
| Vibration resistance | 10–500Hz, amplitude 0.35mm, meeting GB/T 2423 |
| Ambient temperature | -40–+80℃ (junction box) / -200–+600℃ (Mineral-insulated core) |
| Operating pressure | Common pressure –6.4MPa (mineral-insulated protective shield high, small nominal size can 16MPa) |
| Output signal | RTD signal (third line)/ integration 4–20mA + HART transformation (Optional) |
| Ingress protection | IP65 / IP67 (Optional) |
| Applicable standards | IEC 60751 / JB/T 8622 / GB/T 30429 |
| Suitable operating conditions | High Accuracy temperature of bearings, electric circuits, small pipes and containers, HVAC, refrigeration units, experimental devices, etc., and request rapid response |
| Product features | Small outer diameter, low heat inertia, fast response; bendable wiring adapted to narrow space; shock resistance, long life; length and Thread tailored to the field |
Product selection
TEMPSEN-RT-200| Code | Sensing element / sensor type |
|---|---|
| P1 | Pt100 simplex A |
| P2 | Pt100 simplex B |
| P3 | Pt100 Duplex (redundant) |
| P4 | Pt1000 (A Class) |
| Code | Measurement range |
|---|---|
| L1 | -50~+200℃ |
| L2 | -200~+400℃ |
| L3 | -200–+600℃ (Standard) |
| Code | Mineral-insulated probe OD |
|---|---|
| S1 | φ3 |
| S2 | φ4 |
| S3 | φ5 |
| S4 | φ6 (Standard) |
| S5 | φ8 |
| Code | Sheath material |
|---|---|
| M1 | 304 Stainless steel |
| M2 | 316L Stainless steel (resisting) |
| M3 | 321 Stainless steel (Handy-temperature) |
| M4 | Inconel 600 (high temperature corrosion, Optional) |
| Code | Insertion depth L |
|---|---|
| D1 | 50 / 75mm |
| D2 | 100 / 150mm |
| D3 | 200 / 300mm |
| D4 | 500mm |
| D5 | 1000mm and above (Specify when ordering) |
| Code | Process connection |
|---|---|
| F1 | M8×1 Thread |
| F2 | M12×1.5 Thread |
| F3 | M20×1.5 / G½ Thread |
| F4 | Adjustable compression fitting / Spring pressure |
| F5 | No connection (direct lead) |
| Code | Wiring / lead-out |
|---|---|
| O1 | Three-wire + Waterproof junction box |
| O2 | Four-wire + Waterproof junction box |
| O3 | Three-wire + Shielded cable direct-out |
| O4 | Circular connector fast connection |
| Code | Output / explosion protection |
|---|---|
| X1 | RTD signal (Standard) |
| X2 | Integration 4–20mA |
| X3 | Integration 4–20mA + HART |
| X4 | Intrinsically safe Ex ia II C T4 Ga |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us