Preservative thermal resistanceClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
TEMPSEN-RT-250
Preservative thermal resistance
Preservative thermal resistance, preservative thermal resistance
01
Classification: Preservative Thermal Resistor
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | TEMPSEN-RT-250 |
|---|---|
| Measurement principle | Pt100 resistance value changes linearly with temperature (R0=100Ω, α=0.00385), converted from variable/ Display instrument |
| Sensing element | Pt100 / Pt1000 (film or circuit, A / B level); Duplex redundancy Optional |
| Measurement range | -50–+200℃ (PTFE/F46 covered); -200–+450℃ (fluorine + metal tube) |
| Accuracy class | A Level ± (0.15+0.002 | t |) ℃ / B Level ± (0.30+0.005 | t |) ℃ |
| Corrosion-resistant construction | 316L protection tube external PTFE (PTFE) / F46 PFA one-on-one burning, seamless, bare metal |
| Coating thickness | 0.5–1.0mm (Photohole spark test 5kV no punch through) |
| Corrosion resistance range | Strong acids (hydro acids, sulphuric acids, nitrates), strong alkalis, salt solutions, chlorine gases, oxidizing media and most organic solvents |
| Protection tube dimensions | φ12 / φ16 / φ20 × L (insertion depth 100–2000mm Optional); Optional cone head easily inserted |
| Process connection | PTFE covered thread M20×1.5 / M27×2 / G½ / G1; or flange (fluorine flange DN25–DN100) |
| Junction box | Corrupt engineering plastics/enhancement PP junction box IP65 (acid-resistant fog), or 316L Stainless steel box Optional Flameproof type |
| Wiring | Three-wire (Standard) / Four-wire (Optional) |
| Response time | And 0.5 ≤45s (φ16 fluorine liner, medium flow speed ≥0.5m/s) |
| Insulation resistance | ≥100MΩ (500VDC, constant temperature); ≥20MΩ/km cover insulation |
| Vacuum resistance | ≥-0.05MPa |
| Ambient temperature | -20–+80℃ (Junction box) |
| Operating pressure | Constant pressure –1.6MPa (fluorinated); ≤1.0MPa (full PTFE covered) |
| Output signal | RTD signal (third line)/ integration 4–20mA + HART transformation (Optional) |
| Explosion protection marking | Ex d II C T6 Gb flameproof (optional) / Ex ia II C T4 Ga Intrinsically safe (Optional) |
| Applicable standards | IEC 60751 / JB/T 8622 / GB/T 30429 / HG/T 20592 (Flange) |
| Suitable operating conditions | Chemical reaction, acid slurry, electroplating slurry, desulphurized slurry ponds, sewage treatment, salinization, chlor-alkali devices, etc. |
| Product features | Full-covered metallic nudity, completely avoiding point and crystal corrosiveness; integrated with thermal pressure of the tube; Optional cone and fluorine Flange, sealed and reliable |
Product selection
TEMPSEN-RT-250| Code | Sensing element / sensor type |
|---|---|
| P1 | Pt100 simplex A |
| P2 | Pt100 simplex B |
| P3 | Pt100 Duplex (redundant) |
| P4 | Pt1000 (A Class) |
| Code | Measurement range |
|---|---|
| L1 | -50~+100℃ |
| L2 | -50~+150℃ |
| L3 | -50–+200℃ (Standard) |
| L4 | -200–+450℃ (fluorine + metal tube) |
| Code | Corrosion-resistant coating type |
|---|---|
| C1 | PTFE Total covered (generally strong corrosive) |
| C2 | F46 / PFA covered (suffering from heat and permeation) |
| C3 | Fluorine + 316L metal tube (pressure resistant to temperature) |
| C4 | PTFE cover + cone head (easy to insert) |
| Code | Protection tube OD / insertion depth |
|---|---|
| D1 | φ12 × 100 / 150mm |
| D2 | φ16 × 200 / 300mm |
| D3 | φ20 × 500 / 750mm |
| D4 | 1000–2000mm (Specify when ordering) |
| Code | Process connection |
|---|---|
| F1 | PTFE M20×1.5 Thread |
| F2 | PTFE M27×2 / G1 Thread |
| F3 | Fluorine flange DN25 / DN50 |
| F4 | Fluorine flange DN80 / DN100 |
| Code | Wiring / output |
|---|---|
| O1 | Three-wire RTD (Standard) |
| O2 | Four-wire RTD |
| O3 | Integration 4–20mA + HART |
| Code | Junction box / explosion protection |
|---|---|
| X1 | Pulsive plastic box IP65 (Non-Ex) |
| X2 | 316L stainless steel IP65 |
| X3 | Flameproof Ex d II C T6 Gb |
| X4 | Intrinsically safe Ex ia II C T4 Ga |