View selection tables ↓| Model | TEMPSEN-TC-100 |
|---|---|
| Measurement principle | Pt100 resistance value changes linearly with temperature (R0=100Ω, α=0.00385), converted from variable/ Display instrument |
| Sensing element | Pt100 (minus/wire, A / B level), optional Pt1000, duplex Pt100 (redundant) |
| Measurement range | -200–+600℃ (Pt100 Mineral-insulated) |
| Accuracy class | A Level ± (0.15+0.002 | t |) ℃ / B Level ± (0.30+0.005 | t |) ℃ |
| Wiring | Three-wire (Standard) / Four-wire (Optional) |
| Construction | Mineral-insulated Integration: φ3–φ8 mineral-insulated core + 316L Protection of condoms (Physician) φ12–φ16) + Flameproof Junction box |
| Protection tube material | 316L stainless steel (Haze C276 / titanium / PTFE covered Optional) |
| Insertion depth | 75 / 100 / 150 / 200 / 300 / 500mm (Optional with Adjustable compression fitting) |
| Process connection | M20×1.5 / M27×2 / G½ / G1 thread / DN40–DN50 flange (PN1.0–4.0) |
| Junction box | Casting aluminium alloy flameproof junction box, epoxy spray IP66/67 |
| Explosion protection marking | Ex d II C T1–T6 Gb (flameproof type for gas environment 1 / 2) |
| Intrinsic safety option | Ex ia II C T1–T6 Ga (with security fence, applicable to 0) |
| Response time | 0.5 ≤15s (φ12 mineral-insulated, medium flow speed ≥0.5m/s) |
| Insulation resistance | ≥100MΩ (500VDC, constant temperature) |
| Ambient temperature | -40~+80℃ |
| Operating pressure | Constant pressure –4.0MPa (optional 6.4MPa) |
| Output signal | RTD signal (third line)/ integration 4–20mA + HART transformation (Optional) |
| Applicable standards | IEC 60751 / GB 3836.1~2 / JB/T 8622 / GB/T 30429 |
| Suitable operating conditions | Pipelines and containers for flammable explosive sites such as oil, chemicals, natural gas, oil storage tanks, solvent devices, hydrogen gas/acetylene, etc. |
| Product features | Mineral-insulated core bent and resistant to shock; Flameproof box open-covered magnetic pen to zero (integrated delivery); end-of-wielding design |
Product selection
TEMPSEN-TC-100| Code | Sensing element / sensor type |
|---|---|
| P1 | Pt100 simplex A |
| P2 | Pt100 simplex B |
| P3 | Pt100 Duplex (redundant) |
| P4 | Pt1000 (A Class) |
| Code | Measurement range |
|---|---|
| L1 | -200~+200℃ |
| L2 | -200~+400℃ |
| L3 | -200–+600℃ (Standard) |
| Code | Explosion protection type |
|---|---|
| X1 | Flameproof Ex d II C T6 Gb (Standard) |
| X2 | Intrinsically safe Ex ia II C T6 Ga (with security fences) |
| Code | Protection tube material / diameter |
|---|---|
| M1 | 316L stainless steel φ12 |
| M2 | 316L stainless steel φ16 |
| M3 | Haq C276 / titanium (strong corrosive) |
| M4 | PTFE covered (insulation of corruption) |
| Code | Insertion depth L |
|---|---|
| D1 | 75 / 100mm |
| D2 | 150 / 200mm |
| D3 | 300 / 500mm |
| Code | Process connection |
|---|---|
| F1 | M20×1.5 / M27×2 Thread |
| F2 | G½ / G1 thread + Adjustable compression fitting |
| F3 | DN40 / DN50 Flange |
| Code | Wiring / output |
|---|---|
| O1 | Three-wire RTD (Standard) |
| O2 | Four-wire RTD |
| O3 | Integration 4–20mA + HART |