Thermal detonating electrocution.Click on the picture to zoom in.

PRODUCT SPECIFICATIONS

TEMPSEN-TC-150

Thermal detonating electrocution.

Thermal insulation, thermal insulation, applicable to blast-proof settings

01

Classification: Insulated thermoelectric dolls

02

Check configuration based on field work

♪ Back to the blasting thermovolts class

TECHNICAL SPECIFICATIONS

Technical specifications

TEMPSEN-TC-150

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelTEMPSEN-TC-150
Measurement principleThermal power effects: two different metal conductors form circuits, heat and cold temperature differentials generate thermal electrical motion, and the temperature is converted by instrument
Sensor typeK (nickel chromium - nickel silicon) / E / J / T / N / S (Optional)
Measurement rangeK 0–1300℃ / E 0–900℃ / J 0–750℃ / T -200–+350℃ / S 0–1600℃
Accuracy classI Level ±1.5℃ or ±0.4% | t | / II Level ±2.5℃ or ±0.75% | t zirconium (extracts high value)
ConstructionMineral-insulated integrated: φ3–φ8 mineral-insulated chips + 316L/2520 protective tube (φ12–φ20) + Flameproof Junction box
Protection tube material316L stainless steel / 2520 (310S) Heat-resistant steel / Silicon carbide coating (Optional high-temperature grinding)
Insertion depth75 / 100 / 150 / 200 / 300 / 500 / 750mm (Optional with Adjustable compression fitting)
Process connectionM20×1.5 / M27×2 / G½ / G1 thread / DN40–DN80 flange (PN1.0–4.0)
Junction boxCasting aluminium alloy flameproof junction box, epoxy spray IP66/67
Explosion protection markingEx d II C T1–T6 Gb (flameproof type, 1 / 2 gas environment)
Intrinsic safety optionEx ia II C T1–T6 Ga (with security fence, 0 area)
Cold junction compensationJunction box Inline Pt100 Cold junction compensation (when integrated Transmitter)
Response time0.5 ≤12s (φ12 mineral-insulated, medium flow speed ≥0.5m/s)
Insulation resistance≥100MΩ (500VDC, constant temperature)
Ambient temperature-40~+80℃
Operating pressureConstant pressure –4.0MPa
Output signalThermoelectric EMF mV signal / integration 4–20mA + HART transformation (Optional)
Applicable standardsIEC 60584 / GB 3836.1~2 / JB/T 9238 / GB/T 30429
Suitable operating conditionsHigh-temperature, soft-flammable and explosive sites such as oil-heating furnaces, petrochemical crackers, gas pipelines, hydrogen gas/solvent devices, blast-proof ovens, etc.
Product featuresMineral-insulated cortex resistant to shock, bendable wiring; Flameproof box cavity independent, sealing dual shield; Optional heat resistant ceramic Protection tube

Product selection

TEMPSEN-TC-150
Sensor type
CodeSensor type
K1Type K (general, ≤1300℃)
K2E (sensitized, ≤900℃)
K3J (≤750℃)
K4Type T (low temperature -200–350℃)
K5N / S (Specify when ordering)
Measurement range
CodeMeasurement range
L1-200–+400℃ (T master)
L20~800℃
L30–1300℃ (Standard)
L40–1600℃ (S / Specify when ordering)
Accuracy class
CodeAccuracy class
E1Level I
E2II Class (Standard)
Explosion protection type
CodeExplosion protection type
X1Flameproof Ex d II C T6 Gb (Standard)
X2Intrinsically safe Ex ia II C T6 Ga (with security fences)
Protection tube material / diameter
CodeProtection tube material / diameter
M1316L stainless steel φ12
M2316L stainless steel φ16 / φ20
M32520 (310S) Heat-resistant steel (high temperature)
M4Silicon carbide coating (high temperature resistant grinding)
Process connection
CodeProcess connection
F1M20×1.5 / M27×2 Thread
F2G½ / G1 thread + Adjustable compression fitting
F3DN40 / DN80 Flange
F4Welded seats (firewalls/pipes welding)
Output signal
CodeOutput signal
O1Thermoelectric EMF mV output (Standard)
O2Integration 4–20mA + HART

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
TEMPSEN-TC-150 Explosion-Proof Thermocouple