- Thermal dolls.Click on the picture to zoom in.

PRODUCT SPECIFICATIONS

TEMPSEN-TC-250

- Thermal dolls.

Thermal dolls, the costumes, the softer.

01

Classification: Zip-A-Pop

02

Check configuration based on field work

⁇ Return to the assembly thermo-puppet class

TECHNICAL SPECIFICATIONS

Technical specifications

TEMPSEN-TC-250

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelTEMPSEN-TC-250
Measurement principleThermal power effects: two different metal conductors form circuits, heat and cold temperature differentials generate thermal electrical motion, and the temperature is converted by instrument
Sensor typeK (nickel chromium - nickel silicon) / N / E / J / T / S / B (Optional)
Measurement rangeK 0–1200℃ / N 0–1200℃ / E 0–800℃ / J 0–750℃ / T -200–+350℃ / S 0–1600℃
Accuracy classI Level ±1.5℃ or ±0.4% | t | / II Level ±2.5℃ or ±0.75% | t zirconium (extracts high value)
ConstructionMineral-insulated Integration: Thermal electrodes + high purity MgO insulation powder + Stainless steel /heat-resisting alloy shield, pulled back into whole, bendable
Mineral-insulated probe ODφ1.5, φ2, φ3, φ4, φ5, φ6, φ8 (optional, φ3/φ6 Typical)
Sheath material304 / 316L / 321 stainless steel Inconel 600 GH3030 high-temperature alloy Platinum-rhodium Puppet with jade tube
Insertion depth50 / 75 / 100 / 150 / 200 / 300 / 500 / 750 / 1000mm (can be customised for any length)
Minimum bend radius≥5× mineral-insulated probe OD, bends should be at the hot end ≥100mm
Thermal response time0.5 ≤5s (φ3 mineral-insulated) Media flow speed ≥1m/s); φ6 about ≤10s
Process connectionM8×1 / M12×1.5 / M20×1.5 / M27×2 / G½ Thread Adjustable compression fitting Flange, welding Optional
Junction boxWaterproof aluminium alloy/ stainless steel junction box IP65; Splashproof type Flameproof type, Intrinsically safe type Optional
Cold junction compensationJunction box Inline Pt100 Cold junction compensation (when integrated Transmitter)
Insulation resistance≥100MΩ (500VDC, constant temperature); ≥10MΩ (500VDC, 500℃)
Vibration resistance10–500Hz, amplitude 0.35mm, Vibration resistance better than assembly structure
Ambient temperature-40–+80℃ (Junction box)
Operating pressureConstant pressure –16MPa (small Nominal size Mineral-insulated protective shield for high pressure pipe)
Output signalThermoelectric EMF mV signal / integration 4–20mA + HART transformation (Optional)
Ingress protectionIP65 / IP67 (Optional)
Applicable standardsIEC 60584 / JB/T 5582 《 mineral-insulated thermocouple 》/ GB/T 30429
Suitable operating conditionsHigh-temperature high-pressure and vibrating events such as high-voltage steam pipes, steam turbines, gas turbine exhausts, crack furnace walls, engine exhausts, Vacuum furnaces and heat processors
Product featuresSmall outer diameter, low heat inertia, extremely fast response; bendable to adapt to complex measurements; high-pressure resistance to vibration; randomly interceptable unit length to facilitate spare parts management

Product selection

TEMPSEN-TC-250
Sensor type
CodeSensor type
K1Type K (general, ≤1200℃)
K2N (anti-temperature oxidation, ≤1200℃)
K3E (sensitized, ≤800℃)
K4J (≤750℃)
K5Type T (low temperature -200–+350℃)
K6S / B (precious metals, ≤1600/1700℃)
Measurement range
CodeMeasurement range
L1-200~+400℃
L20~800℃
L30–1200℃ (Standard)
L40–1600℃ (Pull metal doll)
Accuracy class
CodeAccuracy class
E1Level I
E2II Class (Standard)
Mineral-insulated probe OD
CodeMineral-insulated probe OD
S1φ1.5 / φ2 (light and quick response)
S2φ3
S3φ4 / φ5
S4φ6 (Standard)
S5φ8
Sheath material
CodeSheath material
M1304 Stainless steel
M2316L Stainless steel (resisting)
M3321 Stainless steel (Handy-temperature)
M4Inconel 600 / GH3030 (high temperature corrosion)
M5Gwangyu tubes (precious metal dolls)
Process connection
CodeProcess connection
F1M8×1 / M12×1.5 Thread
F2M20×1.5 / M27×2 Thread
F3G½ thread + Adjustable compression fitting
F4DN25–DN50 Flange
F5Welding / No connection (direct lead)
Junction box / output
CodeJunction box / output
X1Waterproof boxes IP65 + thermoelectric EMF mV
X2Waterproof boxes IP65 + integrated 4–20mA
X3Flameproof Ex d II C T6 + 4–20mA
X4Shielded cable Directly elicit

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
TEMPSEN-TC-250 Sheathed Thermocouple