Preserve thermal electrocutionClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
TEMPSEN-TC-300
Preserve thermal electrocution
Preservative thermoelectric dolls, preservative thermoelectric dolls
01
Classification: Preservative thermoelectric dolls
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | TEMPSEN-TC-300 |
|---|---|
| Measurement principle | Thermal power effects: two different metal conductors form circuits, heat and cold temperature differentials generate thermal electrical motion, and the temperature is converted by instrument |
| Sensor type | K (nickel chromium - nickel silicon) / J / E / T / N (Optional) |
| Measurement range | K 0–1100℃ (Practical -50–+400℃)/ J 0–600℃ / E 0–600℃ / T -50–+250℃ |
| Accuracy class | I Level ±1.5℃ or ±0.4% | t | / II Level ±2.5℃ or ±0.75% | t zirconium (extracts high value) |
| Corrosion-resistant construction | Double protection: 316L/321 protection tube over PTFE or F46 coating, or + Cyberlined Silicon carbide complex (temperature resistant and excellent) |
| Coating thickness | 0.5–1.0mm (Photo-coated spark test 5kV without impact); Silicon carbon complex 1.5–3mm |
| Corrosion resistance range | Absorption of hydrochloric acid, sulphuric acid, nitrate, hydroflonic acid (silicate carbon), mixed acid, alkaline, salt fog and oxidizing atmosphere |
| Construction | Junction box + preservation protection tube + replacement core without dismantling Process connection |
| Protection tube dimensions | φ16 / φ20 / φ25 × L (insertion depth 150–2000mm Optional) |
| Process connection | PTFE covered thread M27×2 / G1; or fluorine flange DN25–DN100 (PN1.0); or embalming welding seats |
| Junction box | PP or 316L stainless steel junction box IP65 flameproof type Ex d II C T6 Optional |
| Cold junction compensation | Junction box Inline Pt100 Cold junction compensation (when integrated Transmitter) |
| Response time | And 0.5 ≤40s (φ20 fluorine liner, medium flow speed ≥0.5m/s) |
| Insulation resistance | ≥100MΩ (500VDC, constant temperature) |
| Ambient temperature | -20–+80℃ (Junction box) |
| Operating pressure | Constant pressure –1.6MPa (fluorinated); constant pressure –0.6MPa (full PTFE covered) |
| Output signal | Thermoelectric EMF mV signal / integration 4–20mA + HART transformation (Optional) |
| Explosion protection marking | Ex d II C T6 Gb flameproof (optional) / Ex ia II C T4 Ga Intrinsically safe (Optional) |
| Applicable standards | IEC 60584 / GB/T 30429 / JB/T 9238 / HG/T 20592 (Flange) |
| Suitable operating conditions | Medium temperature and strong corrosive conditions such as sulphate/phosphate reaction tanks, titanium powder slurry, non-ferrous metal wet smelting, acid regeneration furnaces, desulphurization flute, fluorine-containing media and amalgamated acid devices |
| Product features | Combination of the preservative layer with the metal base tube, with no break in the temperature resistance; coringable design to reduce maintenance costs; and silic carbon complex to combine grinding resistance with hydroflonic corrosion resistance |
Product selection
TEMPSEN-TC-300| Code | Sensor type |
|---|---|
| K1 | Type K (general, ≤1100℃) |
| K2 | J (≤600℃) |
| K3 | E (sensitized, ≤600℃) |
| K4 | Type T (low temperature -50–+250℃) |
| K5 | N (anti-temperature oxidation) |
| Code | Measurement range |
|---|---|
| L1 | -50~+200℃ |
| L2 | -50~+300℃ |
| L3 | -50–+400℃ (Standard) |
| L4 | 0–600℃ (Silica carbide compound) |
| Code | Accuracy class |
|---|---|
| E1 | Level I |
| E2 | II Class (Standard) |
| Code | Corrosion-resistant construction type |
|---|---|
| C1 | PTFE overlay (ugrene corrosive, ≤200℃) |
| C2 | F46 / PFA wrapping (≤250℃ resistant osmosis) |
| C3 | Fluorine + 316L tube (pressure resistant type) |
| C4 | Silicon carbide complex tubes (silvigen-resistant +, ≤600℃) |
| Code | Protection tube OD / insertion depth |
|---|---|
| D1 | φ16 × 150 / 200mm |
| D2 | φ20 × 300 / 400mm |
| D3 | φ25 × 500 / 750mm |
| D4 | 1000–2000mm (Specify when ordering) |
| Code | Process connection |
|---|---|
| F1 | PTFE M27×2 Thread |
| F2 | PTFE G1 Thread |
| F3 | Fluorine flange DN25 / DN50 |
| F4 | Fluorine flange DN80 / DN100 |
| F5 | Welding seats. |
| Code | Junction box / output |
|---|---|
| X1 | Pulsive plastic boxes IP65 + thermoelectric EMF mV |
| X2 | 316L stainless steel + 4–20mA |
| X3 | Flameproof Ex d II C T6 + 4–20mA |
| X4 | Intrinsically safe Ex ia II C T4 Ga |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us