The mills cut off the thermoelectric dolls.Click on the picture to zoom in.
PRODUCT SPECIFICATIONS
TEMPSEN-TC-400
The mills cut off the thermoelectric dolls.
Warm resistance cuts the thermoelectric dolls, grind resistance cuts, and extend the useful life
01
Classification: grinding to cut the thermoelectric dolls
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | TEMPSEN-TC-400 |
|---|---|
| Measurement principle | Thermal power effects: two different metal conductors form circuits, heat and cold temperature differentials generate thermal electrical motion, and the temperature is converted by instrument |
| Sensor type | K (Nichchromium - Nickel Silicon, standard) / N / E / S (Optional) |
| Measurement range | K 0–1200℃ / N 0–1200℃ / E 0–800℃ / S 0–1600℃ |
| Accuracy class | I Level ±1.5℃ or ±0.4% | t | / II Level ±2.5℃ or ±0.75% | t zirconium (extracts high value) |
| Construction | Cut the valve + grinding protection tube + may be replaced Mineral-insulated doc: close the valve and draw the core with Protection tube under system pressure, and perform unstoppable furnaces (non-stop production) repairs |
| Isolation device | Ball valve (DN25/DN40, PN2.5–PN6.4) or lock valve, valve material (WCB/304/316L), with temperature-resistant seals (soft graphite/metal entanglement pad) |
| Wear-resistant construction | Protection tube front end with thick grinding head (ballhead/pane), tungsten carbide (WC) sprayed / whole silica / high chromium Cast iron / ceramic complex Optional |
| Wear resistance | The hardness of the grinding zone HV1100–1300, adapted to the speed of the flue flow ≥25m/s, the erosion of the fly ash and the wear of fluided bed material, with a life expectancy of 3–5 |
| Protection tube dimensions | φ16 / φ20 / φ25 × L (insertion depth 300–2000mm optional) Insert a grinding section, connect segment 304/316L |
| Process connection | Flange DN25 / DN40 (PN2.5 / PN6.4) connect to cut valves; or direct weld valves |
| Seal Structure | Double sealing of post-valve fillings (soft graphite +O circle) and leaking when pressurized to extract a core |
| Junction box | Waterproof cast iron / 316L stainless steel junction box IP65; flameproof Ex d II C T6 optional high-temperature type to +150℃ |
| Cold junction compensation | Junction box Inline Pt100 Cold junction compensation (when integrated Transmitter) |
| Thermal response time | And 0.5 ≤25s (φ20 grinding tube, medium flow speed ≥5m/s) |
| Insulation resistance | ≥100MΩ (500VDC, constant temperature) |
| Vibration resistance | 10–500Hz, amplitude 0.35mm, match GB/T 2423 |
| Operating pressure | Constant pressure –6.4MPa (cut with valve Pressure rating) |
| Ambient temperature | -40–+80℃ (Junction box) |
| Output signal | Thermoelectric EMF mV signal / integration 4–20mA + HART transformation (Optional) |
| Explosion protection marking | Ex d II C T6 Gb flameproof (optional) / Ex ia II C T4 Ga Intrinsically safe (Optional) |
| Applicable standards | IEC 60584 / GB/T 30429 / JB/T 9238 / GB/T 12237 (ball valve) |
| Suitable operating conditions | Circulation fluidized bed boiler compartments with retortors, gasification furnaces, cement decomposition furnaces, drying and roasting devices, etc., under pressure, dust, wear and tear, and not allowed to stop the furnaces to replace points |
| Product features | Valves are cut + double filling seals, dove cores and Protection tube can be removed online to replace them without shutdown; grinding head and valve specification are complete and can directly replace old products at the original site Flange |
Product selection
TEMPSEN-TC-400| Code | Sensor type |
|---|---|
| K1 | Type K (general, ≤1200℃) |
| K2 | N (anti-temperature oxidation, ≤1200℃) |
| K3 | E (sensitized, ≤800℃) |
| K4 | Type S (platinum-rhodium 10- paranyl, ≤1600℃) |
| Code | Measurement range |
|---|---|
| L1 | 0~600℃ |
| L2 | 0~900℃ |
| L3 | 0–1200℃ (Standard) |
| L4 | 0–1600℃ (S / Specify when ordering) |
| Code | Accuracy class |
|---|---|
| E1 | Level I |
| E2 | II Class (Standard) |
| Code | Wear-resistant tip type |
|---|---|
| W1 | 310S/316L + Tungsten carbide spray (general grinding) |
| W2 | The whole carbide silica SiC (strength punching) |
| W3 | High chromium Cast iron (coarse granular wear) |
| W4 | Ceramic composite tubes (high temperature resistant to grinding) |
| Code | Shutoff valve type |
|---|---|
| V1 | Ball valve DN25, PN2.5 |
| V2 | Ball valve DN40, PN6.4 |
| V3 | Valve DN25 / DN40 |
| V4 | Without valves (Flange, Specify when ordering only) |
| Code | Protection tube OD / insertion depth |
|---|---|
| D1 | φ16 × 300mm |
| D2 | φ20 × 500mm |
| D3 | φ25 × 750 / 1000mm |
| D4 | 1500 / 2000mm (Specify when ordering) |
| Code | Process connection |
|---|---|
| F1 | Flange DN25 PN2.5 |
| F2 | Flange DN40 PN6.4 |
| F3 | Welding valves (firewalls/pipes welding) |
| Code | Junction box / output |
|---|---|
| X1 | Waterproof boxes IP65 + thermoelectric EMF mV |
| X2 | 316L + 4–20mA |
| X3 | Flameproof Ex d II C T6 + 4–20mA |
| X4 | High-temperature type box (environment ≤150℃) |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us