Integrated temperature transmitterClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
TEMPSEN-TT-100
Integrated temperature transmitter
Integrated temperature transmitters, sensors and transmitters
01
Classification: Integrated temperature adapters
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | TEMPSEN-TT-100 |
|---|---|
| Measurement principle | Pt100/K/E et al sensing element signal converted from integration transmitter module linear to V/I output to temperature standard 4–20mA electric current |
| Input signal | RTD: Pt100 (II/III/ IV)/ Pt1000; thermocouple: K / E / J / T / N / S; mV (Optional) |
| Measurement range | Pt100 -200–+600℃; K Type 0–1200℃; E Type 0–800℃; S Type 0–1600℃ (range configurable, minimum span Range Pt100 ≥50℃) |
| Retransmission accuracy | 0.2%FS (standard) / 0.1%FS (Optional); and contains Sensing element Current Total Accuracy Supersede by Widget Level |
| Output signal | Two-wire 4–20mA superseding HART protocol digital communication (Optional) |
| Power supply | DC 24V (12–36VDC wide range, Reverse polarity protection) |
| Load capacity | 0–500Ω (24V when power is provided); recommend typical load 250Ω |
| Cold junction compensation | Module Accuracy cold end automatic compensation (Thermocouple input) |
| Number of terminals | Temperature signal input 2–4 end + power/output 2 endpoint, uncovered, wired once completed |
| Transmitter module | SMAR / Substitute Silicon Emplacement Module, Temperature Resist -40–+85℃ (Inner Surface Environment), Anti-Electromagnetic Interference |
| Isolation method | Enter - output - electrical separation between power sources (separated type optional, quarantine resistant pressure 1.5kV/1min) |
| Construction | Straight-link: mineral-insulated core/ protection tube + top Junction box contents Transmitter module; also equipped modules to be added to existing RTD / Thermocouple |
| Sensing element | Mineral-insulated Pt100 (A/B level) or mineral-insulated K Vector core (Photo core) I/II Level; Duplex Input Optional |
| Protection tube material | 304 / 316L stainless steel (standard); 2520 (310S) / High aluminium / Silicon carbide Optional |
| Protection tube dimensions | φ12 / φ16 × L (insertion depth 75–1000mm Optional) Adjustable compression fitting |
| Process connection | M20×1.5 / M27×2 / G½ / G1 thread; DN25–DN50 flange (PN1.0–4.0); welded seats |
| Junction box | Waterproof aluminium alloy/ 316L stainless steel junction box IP65 (standard); optional band LCD LCD Display header (live reading) |
| Display function | LCD on the surface (optional): 4 display + % display display resolution 0.1℃ |
| Response time | 0.5 ≤15s (φ12 mineral-insulated) Media flow speed ≥0.5m/s); transmitter module sampling cycle ≤1s |
| Insulation resistance | ≥100MΩ (500VDC, constant temperature) |
| Ambient temperature | -40–+85℃ (transmitter module) junction box environment -40–+80℃ |
| Operating pressure | Constant pressure –4.0MPa (high pressure 6.4/16MPa Specify when ordering) |
| Explosion protection marking | Ex d II C T6 Gb flameproof (optional) Ex ia II C T4 Ga Intrinsically safe (Optional with security fence) |
| Ingress protection | IP65 / IP67 (Optional) |
| Applicable standards | IEC 60751 / IEC 60584 / GB/T 30429 / HART 7 compatibility |
| Suitable operating conditions | Remote-mount RTD / thermocouple + Temperature transmitter programme, direct access to DCS/PLC simulation channel |
| Product features | Sensing element integrated with transmitter module, free of long-duration compensation guide, signal resistance to disturbance, distance of transmission; free of HART Configuration Range; modules can be replaced on their own, with low maintenance costs |
Product selection
TEMPSEN-TT-100| Code | Input Sensor/ Sensor type |
|---|---|
| P1 | Pt100 three-wire A |
| P2 | Pt100 three-wire B |
| P3 | Pt100 Duplex (redundant) |
| P4 | K Type thermocouple (II Class) |
| P5 | E / J / T / N (Specify when ordering) |
| P6 | S (≤1600℃) |
| Code | Measurement range |
|---|---|
| L1 | -50~+150℃ |
| L2 | 0~+400℃ |
| L3 | 0~+600℃ |
| L4 | 0–+1200℃ (K) |
| L5 | Other Range (order Configuration) |
| Code | Retransmission accuracy |
|---|---|
| E1 | 0.5%FS |
| E2 | 0.2%FS (Standard) |
| E3 | 0.1%FS |
| Code | Output/Communication |
|---|---|
| O1 | 4–20mA (Standard) |
| O2 | 4~20mA + HART |
| O3 | HART + LCD Display head |
| Code | Structure/ Mounting type |
|---|---|
| S1 | Straight-link (Transmitter module in Junction box) |
| S2 | Approximate (module added to already existing RTD / Thermocouple) |
| S3 | Mineral-insulated integration (thermal core + transformation, φ6~φ8 detail) |
| Code | Protection tube material / diameter |
|---|---|
| M1 | 304 stainless steel φ12 |
| M2 | 316L stainless steel φ12 / φ16 (Standard) |
| M3 | 2520 (310S) Heat-resistant steel (high temperature) |
| M4 | Aluminum piping (≤1300℃, precious metal doll) |
| Code | Insertion depth L |
|---|---|
| D1 | 75 / 100 / 150mm |
| D2 | 200 / 300mm |
| D3 | 500 / 750mm |
| D4 | 1000mm and above (Specify when ordering) |
| Code | Process connection |
|---|---|
| F1 | M20×1.5 / M27×2 Thread |
| F2 | G½ / G1 thread + Adjustable compression fitting |
| F3 | DN25 / DN50 Flange |
| F4 | Welding. |
| Code | Junction box / explosion protection |
|---|---|
| X1 | Waterproof aluminium alloy boxes IP65 (Non-Ex) |
| X2 | 316L stainless steel IP65 (resistible) |
| X3 | Flameproof Ex d II C T6 Gb |
| X4 | Intrinsically safe Ex ia II C T4 Ga |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us