Eight-way flash alarm.Click on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-AL-100
Eight-way flash alarm.
Eight-way flash alarm, eight-way flash alarm.
01
Classification: -way flash alarm
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-AL-100 |
|---|---|
| Product function | Focus 8 on an independent switch limit signal into a Alarm screen with a light window: a light flash and a sound for a window when any road moves, the watchman keeps the light flat as confirmed, and the failure goes off as a repeat position; to avoid multiple points Alarm while the key signals are missing when the main picture is in the air |
| Input loop | 8 road independent input, photo-separation; input type optional dry contact (voltage-free contact), wet contact (24VDC level) TTL level of electricity, mixed in the same table |
| Input characteristics | Dry contact Backway offers. 24VDC / 5mA Query voltage; wet contact High level. ≥18V And judge the movements, ≤5V determine return;input filters 20ms (b) Wrestleproofness; isolation voltage 1500VAC |
| Alarm mode | Exceeding is flash (1.5Hz, light 60% dark 40%) and drive sound; smoothing (normally) and phoning after the confirmation key has been pressed; remaining flat after the malfunction has disappeared, using the double key until it has been extinguished to ensure that the duty officer has seen the alarm |
| Sound | Internal beeper ≥85dB (range 10cm); optional external sound player (source DC24V or relay driver); volume adjustable, sound silence (simplified silence 60s, automatic recovery to prevent permanent leaking) |
| Panel annunciator windows | 8 30×26mm light window with a change of sign for each window (Chinese 4 word/ line, two rows 8 word); colour of the light window Optional red, yellow, green, more restricted colours can be specified by road; tiles are plug-in and change cards should be changed |
| Test function | Light test keys to light all the windows and sound at once for shift switching and self-checking; the test process does not affect the Alarm state and First-out memory being recorded |
| First-out memory | Record 8 of the lead movement and single-handedly use quick flash marking; multiple points and simultaneous jumps can be used to determine the starting point of the accident. |
| Output contacts | Independent relays per road 1 (250VAC/2A); and optional public alarm contact 1 (or closed to any limit) and sound 1 (for external receivers or locks) |
| Communication interface | Optional RS485 (Modbus RTU from station): 8 road state, remote execution confirmation and reset, upload alarm DCS or PLC |
| Power supply | AC 85–265V (50/60Hz) or DC 24V, power ≤10VA; optional dual power source redundancy input (AC and DC automatically switch, power failure Alarm) |
| Enclosure and protection | Disk 160×80mm transverse structure, front plate protection IP54, back end IP20 |
| Panel cutout dimensions | 152 × 76mm (wide × high), insertion depth ≤130mm |
| Instrument weight | 1.1kg |
| Applicable standards | JB/T 7352 (light alarm in industrial process measurement and control systems)/ GB/T 17626 (EMC)/ GB/T 34037 |
| Typical applications | Small and medium-sized boiler rooms, water treatment stations, air pressure stations, heat exchange stations, displaying and casting workshops, test stands, etc., are used to provide an over-the-horizon alert for unmanned or under-staffed positions; also for old devices to integrate dispersed single lamps Alarm into one screen |
| Product features | 8 road entry can be mixed Wet contact, re-engineered project is simple; First-out memory lets the accident reset clear which path to go first |
Product selection
VISCON-AL-100| Code | Number of loops |
|---|---|
| A4 | 4 backway |
| A8 | 8 backway (Standard) |
| A16 | 16 Backway (two parallels, interconnected cables) |
| Code | Input Type |
|---|---|
| I1 | Dry contact (Voltage-free contact) |
| I2 | Wet contact 24VDC |
| I3 | TTL level |
| I4 | Dry and wet mix, road by road Configuration (Standard) |
| Code | Light window colour |
|---|---|
| C1 | Full Red |
| C2 | Red + yellow |
| C3 | Red / Yellow / Green Three, road by road |
| Code | Audible alarm configuration |
|---|---|
| S1 | Internal beeper (≥85dB) |
| S2 | Internal beeper + external sounder interface (Standard) |
| S3 | External receivers only (relay drive, volume on site) |
| Code | Output contacts |
|---|---|
| P1 | Public alarm 1 group |
| P2 | Independent 1 each route (250VAC/2A) |
| P3 | Independent + public alarm + sound contact (Standard) |
| Code | Function Options |
|---|---|
| F1 | Standard Flash / Confirm / Restore |
| F2 | F1 + First-out memory |
| F3 | F2 + silence time (60s automatically restored) |
| Code | Communication interface |
|---|---|
| T0 | Communication |
| T1 | RS485(Modbus RTU) |
| T2 | RS485 + dry contact event output (for DCS record) |
| Code | Power supply |
|---|---|
| V1 | AC 220V(85~265V) |
| V2 | DC 24V |
| V3 | Double power redundancy (AC + DC automatic switch) |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us