Eight-way flash alarm.Click on the picture to zoom in.

PRODUCT SPECIFICATIONS

VISCON-AL-100

Eight-way flash alarm.

Eight-way flash alarm, eight-way flash alarm.

01

Classification: -way flash alarm

02

Check configuration based on field work

Zipper, return eight-way flash alarms.

TECHNICAL SPECIFICATIONS

Technical specifications

VISCON-AL-100

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelVISCON-AL-100
Product functionFocus 8 on an independent switch limit signal into a Alarm screen with a light window: a light flash and a sound for a window when any road moves, the watchman keeps the light flat as confirmed, and the failure goes off as a repeat position; to avoid multiple points Alarm while the key signals are missing when the main picture is in the air
Input loop8 road independent input, photo-separation; input type optional dry contact (voltage-free contact), wet contact (24VDC level) TTL level of electricity, mixed in the same table
Input characteristicsDry contact Backway offers. 24VDC / 5mA Query voltage; wet contact High level. ≥18V And judge the movements, ≤5V determine return;input filters 20ms (b) Wrestleproofness; isolation voltage 1500VAC
Alarm modeExceeding is flash (1.5Hz, light 60% dark 40%) and drive sound; smoothing (normally) and phoning after the confirmation key has been pressed; remaining flat after the malfunction has disappeared, using the double key until it has been extinguished to ensure that the duty officer has seen the alarm
SoundInternal beeper ≥85dB (range 10cm); optional external sound player (source DC24V or relay driver); volume adjustable, sound silence (simplified silence 60s, automatic recovery to prevent permanent leaking)
Panel annunciator windows8 30×26mm light window with a change of sign for each window (Chinese 4 word/ line, two rows 8 word); colour of the light window Optional red, yellow, green, more restricted colours can be specified by road; tiles are plug-in and change cards should be changed
Test functionLight test keys to light all the windows and sound at once for shift switching and self-checking; the test process does not affect the Alarm state and First-out memory being recorded
First-out memoryRecord 8 of the lead movement and single-handedly use quick flash marking; multiple points and simultaneous jumps can be used to determine the starting point of the accident.
Output contactsIndependent relays per road 1 (250VAC/2A); and optional public alarm contact 1 (or closed to any limit) and sound 1 (for external receivers or locks)
Communication interfaceOptional RS485 (Modbus RTU from station): 8 road state, remote execution confirmation and reset, upload alarm DCS or PLC
Power supplyAC 85–265V (50/60Hz) or DC 24V, power ≤10VA; optional dual power source redundancy input (AC and DC automatically switch, power failure Alarm)
Enclosure and protectionDisk 160×80mm transverse structure, front plate protection IP54, back end IP20
Panel cutout dimensions152 × 76mm (wide × high), insertion depth ≤130mm
Instrument weight1.1kg
Applicable standardsJB/T 7352 (light alarm in industrial process measurement and control systems)/ GB/T 17626 (EMC)/ GB/T 34037
Typical applicationsSmall and medium-sized boiler rooms, water treatment stations, air pressure stations, heat exchange stations, displaying and casting workshops, test stands, etc., are used to provide an over-the-horizon alert for unmanned or under-staffed positions; also for old devices to integrate dispersed single lamps Alarm into one screen
Product features8 road entry can be mixed Wet contact, re-engineered project is simple; First-out memory lets the accident reset clear which path to go first

Product selection

VISCON-AL-100
Number of loops
CodeNumber of loops
A44 backway
A88 backway (Standard)
A1616 Backway (two parallels, interconnected cables)
Input Type
CodeInput Type
I1Dry contact (Voltage-free contact)
I2Wet contact 24VDC
I3TTL level
I4Dry and wet mix, road by road Configuration (Standard)
Light window colour
CodeLight window colour
C1Full Red
C2Red + yellow
C3Red / Yellow / Green Three, road by road
Audible alarm configuration
CodeAudible alarm configuration
S1Internal beeper (≥85dB)
S2Internal beeper + external sounder interface (Standard)
S3External receivers only (relay drive, volume on site)
Output contacts
CodeOutput contacts
P1Public alarm 1 group
P2Independent 1 each route (250VAC/2A)
P3Independent + public alarm + sound contact (Standard)
Function Options
CodeFunction Options
F1Standard Flash / Confirm / Restore
F2F1 + First-out memory
F3F2 + silence time (60s automatically restored)
Communication interface
CodeCommunication interface
T0Communication
T1RS485(Modbus RTU)
T2RS485 + dry contact event output (for DCS record)
Power supply
CodePower supply
V1AC 220V(85~265V)
V2DC 24V
V3Double power redundancy (AC + DC automatic switch)

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
VISCON-AL-100 8-Channel Lamp Annunciator