Smart Digital Flash AlertClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

VISCON-AL-150

Smart Digital Flash Alert

Smart Digital Flash Alert, Smart Digital Flash Alert

01

Classification: Smart digital flash alarm

02

Check configuration based on field work

⁇ Return Smart Digital Flash Warning Category

TECHNICAL SPECIFICATIONS

Technical specifications

VISCON-AL-150

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelVISCON-AL-150
Product functionAdd a bit of liquid crystal to the traditional flash Alarm: make the Han character description, action time and current state of every road a list of textable pages Configuration done with the electric-capable key menu or the upper machine software; suitable for the frequent change of the point, the need to leave Alarm log, without wanting to change the lightboard fonts one by one
Input loopStandard 8 Lou, optional 16 / 24 / 32 Roads; photo-separation, isolation voltage 1500VAC;routing optional dry contact, wet contact 24VDC, TTL Level
Input characteristicsDry contact Query voltage 24VDC / 5mA; wet contact High level ≥18V Decision Action; input filter 10–1000ms on a road-by-road basis to avoid misrepresentation caused by the contact vibrating and transient interference
Display unit128×64 dot-string liquid crystal (optional 3.5 inch colour screen), 4 line × 12 Han; scroll display bits, 12 characters per road, action time (hours: seconds) and current state
Alarm sequenceThe selection can be made from the time series of the four industries by road: 1 flash-confirmation-reverse; 2 flash-confirmation-peace-reverse; 3 start-up flash, remaining flat light; 4 beam-free (minor hints); and one hardware suitable for multiple workshop habits can be used for different paths within the same table.
Audible and visual outputPanel LED indicates three states of excess, confirmation, failure; built-in beepers ≥85dB, Optional external transmitters; sound mode can be continuous, intermittent, silent
First-out and sequence memoryBefore recording 8 Alarm action sequence and millisecond timescale, which can be viewed over the LCD page and used to restore the accident chain
Alarm logInline 4MB iron storage without loss of power; available 1000 event (channel number, action or restoration, time) to support retrieval by time or channel and direct viewing on screen without the need to connect computers
Output contacts1 group relays (250VAC/2A) or 8/16 road shared group public contact points; plus three sets of auxiliary contact points Alarm, sound, malfunction (power failure or self-check failure)
Configuration methodPanel four-key Chinese menu configuration (with password protection); or RS485 with upholstery software batch number, Alarm sequence and filter time, one-time configuration of the whole screen
Communication interfaceRS485 (Modbus RTU from station) standard; optional Ethernet; supports the active uploading of alarm event to the top or DCS, and the memory map can be customised
Self-diagnosisRoad-by-way detection Input loop breakwire, short circuit, relay drive failure and power voltage anomaly; when failure is detected, the failure light is activated and text tips are given to avoid the failure of the Alarm device itself without any knowledge
Power supplyAC 85–265V (50/60Hz) or DC 24V, power ≤12VA; Optional double power redundancy input
Enclosure and protectionDisk assembly 160×80mm or 96×96mm, front plate protection IP54 (optional IP65), backend IP20
Panel cutout dimensions152 × 76mm (160×80)/ 92 × 92mm (96×96), insertion depth ≤150mm
Instrument weightAbout 1.2kg (32 road configuration)
Applicable standardsJB/T 7352 (light alarm) / GB/T 17626 (EMC) / GB/T 34037 (industrial process measurement recorder)
Typical applicationsMulti-point locktips for chemical and pharmaceutical laboratories, kiln burning and winder state surveillance, water plant pump and pumping systems, air room environment and fire protection, test stage multi-road monitoring, remote alert front for unmanned stations
Product featuresThe Han character description is direct Display (a) On screen, no more labeling; Alarm sequence I'll take it from here. Optional A set of hardware can accommodate both old operating habits and new norms; time-standarded incident logs allow for accident re-entry to be documented; Configuration The software will be distributed in bulk without the need to break the panel; there will be self-diagnosis and no silence at a critical time

Product selection

VISCON-AL-150
Number of loops
CodeNumber of loops
N088 backway
N1616 backway (Standard)
N2424 backway
N3232 backway
Input Type
CodeInput Type
I1Dry contact
I2Wet contact 24VDC
I3TTL level
I4Dry and wet mix, road by road Configuration (Standard)
Display configuration
CodeDisplay configuration
D1128×64 dot array crystal (Standard)
D23.5 inch colour screen (colour distinction exceeding limit/restoration)
D3+ independent of every road LED indicator
Alarm sequence
CodeAlarm sequence
Q1Flash - Confirm - Restore
Q2Flash - Confirm - Flat - Reset (Standard)
Q3The flash, the rest of the light.
Q4Road-by-road (four time series mixed)
Recording capacity
CodeRecording capacity
M0No incidents recorded
M11000 incidence (4MB iron, Standard)
M21000 + 8MB extension (approximately 20000)
Output contacts
CodeOutput contacts
P1Group Public Contacts (8 Roads 2 Group)
P2Independent 1 each route (250VAC/2A)
P3Three sets of aids + public/sound/facility per road (Standard)
Communication interface
CodeCommunication interface
T0Communication
T1RS485(Modbus RTU)
T2RS485 + Ethernet
Power supply
CodePower supply
V1AC 220V(85~265V)
V2DC 24V
V3Double power redundancy (AC + DC automatic switch)

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
VISCON-AL-150 Intelligent Digital Annunciator with Text Display