PRODUCT SPECIFICATIONS
VISCON-AU-100
Pressure autochecker
Pressure autovalidation devices, pressure autovalidation devices, covering vacuum to high pressure
01
Classification: Pressure autovalidation device
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-AU-100 |
|---|---|
| Operating principle | Auto-pressure + smart fine-modulated valve closed ring pressure, compared to Standard pressurer, self-capturing, interpretation and production of calibration/correction logs for the upper machine software |
| Pressure range | Air pressure: -0.095–+6.0MPa (clean air/nitrogen gas); hydraulic pressure: 0–60MPa (available 70MPa, Specify when ordering) |
| Pressure control stability | Volatility ≤0.005%FS / 10s (after steady pressure); automatic micro-movement to check point without manual pressurization |
| Pressure generation method | Internal oil-free piston gas pump (pressure type) / electric piston pump (prime pressure type) + servation microlytic valves; increase rate can be set |
| Verification point management | Automatically generate a control point sequence (≥5/11 point, up - return two-way) by protocol, a point-by-point steady pressure hint, an automatic interpretation of the detected value |
| Compatible reference instruments | 0.05 Level / 0.02 Level Digital Pressure Validator (standard); optional 0.02 Pistol Pressurer; user readiness Reference instrument is also directly accessible |
| Accuracy class | Device combination uncertainty ≤0.05%FS (with 0.05 class reference instrument) / ≤0.02%FS (with 0.02 class) |
| Instruments under test | Pressure Transmitter (Gauge pressure / Differential pressure / Absolute pressure), precision pressure sheet, normal pressure table, pressure switch/pressure controller, pressure sensor |
| Instrument test stations | Standard 2 places; optional 4 / 6 / 10 places (fast plugs, empty valves) |
| Applicable calibration regulations | JJG 882 Pressure transmitter / JJG 49 bourdon tube General Precision Pressure Sheet/ JJG 52 bourdon tube General Pressure Sheet/ JJG 875 Digital Pressure Sheet/ JJG 544 Pressure Control |
| Power supply | AC 220V ±10%, 50Hz, whole power ≤1.5kW |
| Gas supply requirements | Pressure-type inner pump, without external source; also external 0.4–0.8MPa clean compressed air speed |
| Working medium | Clean air or nitrogen gas (pressure type); transformer oil / pure water (prime pressure type, oily water separation and filtering) |
| Communication interface | RS232 (standard)/ USB / RS485, Ethernet (Optional); support access measurement measurement management system |
| Software functionality | Automatically collect reference instrument with tested data, computational error and repetition, automatic certification by protocol, generation of original records and calibration/correction certificates (Word/PDF), support for billing and bar code management (Optional) |
| Display and controls | 7 " Industrial touch screen local operation (pressure/pressure/reading), which is also controlled by the upper machine |
| Safety protection | Super-pressure automatic discharge, limit stop, hose bursting shield; hydraulic-type oil-contaminated collector |
| Environmental conditions | Temperature 5–35℃, relative humidity ≤85%RH, no strong vibration and corrosive gases |
| Overall dimensions | Host 700×500×1100mm (wide × depth × height standard 2 space configuration) |
| Instrument weight | About 75kg (pressure type); about 90kg hydraulic type |
| Applicable standards | JJF 1094 Measuring Instrument Characteristics / JJG 882 / JJG 875 / GB/T 17626 (EMC) |
| Typical applications | Periodic check and calibration of pressure Transmitter, pressure gauge, pressure switches by metering and instrumentation plant, plant and petrochemical equipment workshop |
| Product features | EBA instead of hand-shake/hand-push, check efficiency increase 3–5 times; emitter modular configuration, a set of devices covering vacuum to 60MPa; protocol library built in, certificate generation |
Product selection
VISCON-AU-100| Code | Pressure range module |
|---|---|
| G1 | -0.095–+0.6MPa (pressure, Vacuum complex) |
| G2 | 0–6MPa (air pressure) |
| G3 | 0–25MPa (prime pressure) |
| G4 | 0–60MPa (prime pressure) |
| G5 | 0–70MPa (prime pressure, Specify when ordering) |
| Code | Working medium |
|---|---|
| M1 | Clean air (internal pump) |
| M2 | Nitrogen (outside gas source) |
| M3 | Transformer oil (liquid pressure) |
| M4 | Pure water (prime pressure, no-oil scenarios) |
| Code | Instruments under calibration |
|---|---|
| O1 | Pressure Transmitter (Gauge pressure / Differential pressure) |
| O2 | Precision/ordinary pressure table |
| O3 | Pressure Switch / Pressure controller |
| O4 | Multiple types of mixer (full function) |
| Code | Instrument test stations |
|---|---|
| N1 | 2 Workspace (Standard) |
| N2 | 4 |
| N3 | 6 |
| N4 | 10 |
| Code | Reference instrument configuration |
|---|---|
| S1 | 0.05 Class Digital Pressure Validator |
| S2 | 0.02 Class Digital Pressure Validator |
| S3 | 0.02 Class Pistol pressureometer |
| S4 | Host only (Reference instrument custom) |
| Code | Control Mode |
|---|---|
| C1 | Semi-automatic (touch screen pressure + manual interpretation) |
| C2 | Full Auto (top control + automatic interpretation) |
| Code | Software functionality |
|---|---|
| W1 | Basic collection + certificate generation |
| W2 | Certificate + instrument/barcode management |
| W3 | Online version (multi-end/database) |
| Code | Communication interface |
|---|---|
| R1 | RS232 (Standard) |
| R2 | USB |
| R3 | RS485 |
| R4 | Ethernet (Optional) |