Multi-channel thermoelectric dolls, thermoelectric resistance auto-checking devicesClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

VISCON-AU-150

Multi-channel thermoelectric dolls, thermoelectric resistance auto-checking devices

Multichannel thermoelectrical dolls, ATM, ATM

01

Classification: Multichannel thermoelectric dolls, thermoelectric resistance auto-checking devices

02

Check configuration based on field work

⁇ Return multi-channel thermoelectric dolls, automatic verification devices

TECHNICAL SPECIFICATIONS

Technical specifications

VISCON-AU-150

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelVISCON-AU-150
Operating principleHeat source(s) Dry-block calibrator / Temperature bath) Provide a stable temperature field, multiple corridors Low-EMF scanning Switching wheeled access tested/blocked, high Accuracy Numbers more automatically capture the power/retardation values by the table, and Reference instrument Matches. Upboard software interprets and produces certificates according to protocol.
Instruments under calibrationAssembly/ mineral-insulated thermocouple (K, N, E, J, T, S, R, B Industrial platinum/copper RTD (Pt100, Pt10 00, Cu50, Cu100 integrated temperature transmitter (Hands) 4–20mA Signal acquisition)
Number of channelsStandard 8 channel (separate connection per channel, which can be checked simultaneously 8 branch); optional 16 / 32 channel extension
Temperature rangeType dry-block calibrator: 30–1200℃ (two segments of the oven); temperature bath: -40–+300℃ (optional -80–+300℃); double configuration coverage -80–+1200℃
Heat source configurationDry-block calibrator (portable/on-line, stowage multi-perforcing), precision Temperature bath (water/oil/alcohol), piped calibration furnace (precious metal for occasional use, with an average thermometer) Optional
Heat source stabilityDry-block calibrator ≤±0.05℃/10min, even ≤0.1℃ (typical); temperature bath ≤±0.01℃/10min, horizontal temperate ≤0.005℃
Electrical measurement unit6½ bit height accuracy numeric multiple table (standard); direct current voltage resolution 0.1μV, electrical resistance resolution 0.1mΩ optional 7½ bit
Low-EMF scanningRelay/solid switch low thermoelectric EMF scanner, parasite thermoelectric EMF ≤0.2μV, inter-channel separation
Reference junction treatmentIce point thermostat (0℃) or precision reference end remedyer (optional); precious metals can only use reference end 0℃ precision ice bottle
Reference instrument configurationSecond class standard paralycol resist thermometers (train) / standard platinum-rhodium 10- platinum Thermocouple / First class Standard (Optional); Reference instrument self-accessible
System uncertaintyRTD Validation U ≤0.03℃ (k=2); Affordable Metal Puppet U ≤0.3℃ (k=2); meeting transmission requirements to work thermometers
Applicable calibration regulationsJJG 229 "Industrial Platinum, Copper." RTD 》/ JJG 351 "Current metal for work" thermocouple 》/ JJG 141 Precious Metals for Work thermocouple 》/ JJG 368 "Bron for Work" - Copper nickel (cronium) thermocouple 》/ JJF 1098 (calibration norms)
Verification point managementAutomatically generate check points (Zinc, Aluminium, Copper or Integer) by protocol, point-by-point stabilization tips, automatic collection, double-direction (up and down) verification
Software functionalityMulti-channel parallel collection and interpretation, automatic calculation of login error and repetition, protocol determination, generation of original records and calibration/calibration certificates (Word/PDF), instrument desk accounts and certificate management; support mass labelling
Display and controls7 " Industrial Touch screen (thermal source temperature display) + Accelerator full process control; supporting breakpoint checking
Communication interfaceRS232 (standard) / USB / RS485, Ethernet (Optional); access measurement measurement management system
Power supplyAC 220V ±10%, 50Hz; whole power ≤3.5kW (Dry-block calibrator)
Environmental conditionsTemperature 5–35℃, relative humidity ≤85%RH, no strong vibration and corrosive gases
Overall dimensionsElectro-scan cabinets 600×550×1200mm; heat source (Dry-block calibrator / Temperature bath) are stand-alone aircraft boxes, sized and configured
Instrument weightElectric scanning cabinets 45kg; heat-source configuration (dry-block calibrator approximately 15kg, temperature bath approximately 40kg)
Applicable standardsJJF 1094 Measuring Instrument Characteristics / JJG 229 / JJG 351 / GB/T 17626 (EMC)
Typical applicationsThe metering unit, the thermometer manufacturing plant, the plant and the petrochemical company instrumentation workshop Thermocouple, RTD And integrated temperature. Transmitter Periodicity and mass calibration
Product featuresMulti-channel parallel checks, batches. 8–32 It's a good time to get in. simplex It's checked. 8 More than twice as many; dry-block calibrator + temperature bath (b) Modularized combinations to cover all-temperature zones; low-EMF scanning Promise. μV Level capture reliable; protocol library built in, certificate first generated

Product selection

VISCON-AU-150
Instruments under calibration
CodeInstruments under calibration
P1Industrial platinum/copper RTD (Pt100/Pt1000/Cu50/Cu100)
P2Low metal thermocouple (K/N/E/J/T)
P3Precious metals thermocouple (S/R/B)
P4Integrated temperature transmitter (4–20mA)
P5Full-type mixer
Heat source configuration
CodeHeat source configuration
H1Dry-block calibrator 30–1200℃
H2Precision temperature bath -40–+300℃
H3Dry-block calibrator + temperature bath double configuration (-80–+1200℃)
H4Plumber calibration (precious metal dolls, equal thermometers)
Number of channels
CodeNumber of channels
N18 channel (Standard)
N216 channel
N332 channel
Electrical measurement unit
CodeElectrical measurement unit
E15½ multi-digit table
E26½ bits more than table (Standard)
E37½ bits more than the table (high Accuracy)
Reference instrument configuration
CodeReference instrument configuration
S1Second class Standard Platinum Resisting Thermometer (Truck)
S2Standard platinum-rhodium 10- Thermocouple (bore)
S3Double reference instrument configuration (truck + furnace)
S4Electric scanning cabinets only (Reference instrument available)
Reference junction treatment
CodeReference junction treatment
C1Ice point thermostat (0℃)
C2Precision Reference End Compensator
C3Precision ice bottles + Ice point thermostats (precious metals)
Software functionality
CodeSoftware functionality
W1Basic collection + certificate generation
W2Certificate + instrument/barcode management
W3Online version (multi-end/database)
Communication interface
CodeCommunication interface
R1RS232 (Standard)
R2USB
R3RS485
R4Ethernet (Optional)

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
VISCON-AU-150 Multi-Channel Thermocouple & RTD Automatic Calibration System