Smart applianceClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-DIS-100
Smart appliance
Smart appliance, smart appliance.
01
Classification: Smart appliance
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-DIS-100 |
|---|---|
| Product function | DC 24V distribution power distribution for the second-line system transmitter, with transmitter 4–20mA output signal quarantined and distributed into two separate outlets to DCS, recorder or local Display table, to achieve a little collection, multiple usage |
| Channel configuration | Standard one input, two outputs (1 path input, 2 road independently isolated output) Optional One input, one output, Two inputs, two outputs |
| Input signal | 4–20mA (2-line transmitter with electricity); also 4–20mA three-wire / four-wire signal (input impedance ≤50Ω without electricity); support 0–20mA |
| Transmitter excitation | Isolated distribution DC 24V (aerial)/ output current ≤30mA; short-circuit limit protection (≤35mA), allowing long-term short-circuits at the end of the output to be undamaged; distributed voltage finely (22–26V) |
| Output signal | 4–20mA (load ≤500Ω); optional 1–5V (load ≥250kΩ), 0–10V; the two can be set Range and positive/reverse (smart type) respectively |
| HART pass-through | Support HART for two-way transparent transmission (output 1 channel) at Safe area Transmitter Configuration, Range and diagnosis without the need to get to the scene |
| Conversion accuracy | ±0.1%FS (23±2℃); temperature drift ≤0.015%FS/℃; all-temperature -20–+60℃ ≤±0.3%FS |
| Output Load capacity | 0–500Ω (24V when power is provided); voltage ≥250kΩ; output short circuit protection |
| Isolation performance | Input - output 1 — output 2 — power source 4x4; isolation voltage 1500VAC/1min; insulation resistance ≥100MΩ (500VDC); common-mode rejection ≥120dB |
| Response time | ≤50ms (10%–90% step change); available damping time 0–30s |
| Open-circuit protection | Enter the two-way output for the breakout by setting an upspill (≥22mA) or downspill (≤3.6mA), with programmable options |
| Configuration method | Panel key + LCD display (intellectual), or PC Software implementation USB Configuration;parameters are electrically saved; input can be set Range, Output Range, zero points/plenour fine-tuning |
| Display | Optional 2.4 inch LCD, cycle display input current, output 1, output 2 & percentage (smart Display type) |
| Power supply | DC 20–35V (Performance 24V) or AC 85–265V (fluent type, internal switch power); power consumption ≤2.5W |
| Mounting | 35mm standard DIN rail carcass; thickness 18mm (One input, two outputs) |
| Wiring | Plugged screws (2.5mm2), input/output/power partitioning |
| Operating environment | Temperature -20–+60℃, relative humidity ≤95%RH (Non-condensing) |
| Overall dimensions | 18 × 110 × 118mm (wide × high × deep) |
| Instrument weight | 0.15kg |
| Applicable standards | GB/T 17626 (EMC)/ IEC 61000-6-2 / GB/T 18271 (process measurement and control device performance assessment) |
| Typical applications | Distribution and signal distribution of pressure/ differential pressure / level /temperature transmitter in installations such as oil, chemicals, electricity, metallurgical and water treatment; especially suitable for the same location to be supplied at the same time DCS separate from the local recorder or safety instrument system |
| Product features | Power distribution is integrated with signal distribution, free of additional distribution modules and distributors; two-way output is isolated from each other, short-circuited or adjoining the other; HART transparency, smart Transmitter Configuration is exempted from the scene; short-circuit limit flow protection, on-site connection failure does not damage the equipment; distribution voltage is fine-tuned and adapted to long-range cable pressure reduction |
Product selection
VISCON-DIS-100| Code | Channel configuration |
|---|---|
| C1 | One input, one output |
| C2 | One input, two outputs (Standard, separate roads) |
| C3 | Two inputs, two outputs |
| Code | Input Method |
|---|---|
| I1 | Second-line transmitter (with 24V distribution) |
| I2 | Three-wire / Four-wire (without electricity) |
| I3 | / Without electricity toggle |
| Code | Output signal |
|---|---|
| O1 | Two roads 4–20mA (Standard) |
| O2 | Two roads 1–5V |
| O3 | 4–20mA + 1–5V |
| O4 | Two roads 4–20mA + Alarm |
| Code | Accuracy class |
|---|---|
| A1 | ±0.1%FS (Standard) |
| A2 | ±0.2%FS (Economy type) |
| A3 | ±0.05%FS (high Accuracy, order) |
| Code | Transmitter supply capacity |
|---|---|
| P1 | 24V / 30mA (Standard) |
| P2 | 24V / 50mA (high power) |
| P3 | 22–26V adjustable / 30mA |
| Code | Display and configuration |
|---|---|
| D1 | no display, PC Configuration |
| D2 | LCD display + Key Configuration (Intelligence) |
| D3 | D2 + USB Configuration with data export |
| Code | Power supply |
|---|---|
| S1 | DC 24V(20~35V) |
| S2 | AC 85–265V broad pressure |
| S3 | DC 24V redundant double-track input |
| Code | Special function |
|---|---|
| F1 | Basic Type |
| F2 | Programable on/offline |
| F3 | F2 + output block adjustable (0–30s) |
| F4 | F3 + square root flow conversion |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us