Smart applianceClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

VISCON-DIS-100

Smart appliance

Smart appliance, smart appliance.

01

Classification: Smart appliance

02

Check configuration based on field work

⁇ Return Smart Appliance Classification

TECHNICAL SPECIFICATIONS

Technical specifications

VISCON-DIS-100

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelVISCON-DIS-100
Product functionDC 24V distribution power distribution for the second-line system transmitter, with transmitter 4–20mA output signal quarantined and distributed into two separate outlets to DCS, recorder or local Display table, to achieve a little collection, multiple usage
Channel configurationStandard one input, two outputs (1 path input, 2 road independently isolated output) Optional One input, one output, Two inputs, two outputs
Input signal4–20mA (2-line transmitter with electricity); also 4–20mA three-wire / four-wire signal (input impedance ≤50Ω without electricity); support 0–20mA
Transmitter excitationIsolated distribution DC 24V (aerial)/ output current ≤30mA; short-circuit limit protection (≤35mA), allowing long-term short-circuits at the end of the output to be undamaged; distributed voltage finely (22–26V)
Output signal4–20mA (load ≤500Ω); optional 1–5V (load ≥250kΩ), 0–10V; the two can be set Range and positive/reverse (smart type) respectively
HART pass-throughSupport HART for two-way transparent transmission (output 1 channel) at Safe area Transmitter Configuration, Range and diagnosis without the need to get to the scene
Conversion accuracy±0.1%FS (23±2℃); temperature drift ≤0.015%FS/℃; all-temperature -20–+60℃ ≤±0.3%FS
Output Load capacity0–500Ω (24V when power is provided); voltage ≥250kΩ; output short circuit protection
Isolation performanceInput - output 1 — output 2 — power source 4x4; isolation voltage 1500VAC/1min; insulation resistance ≥100MΩ (500VDC); common-mode rejection ≥120dB
Response time≤50ms (10%–90% step change); available damping time 0–30s
Open-circuit protectionEnter the two-way output for the breakout by setting an upspill (≥22mA) or downspill (≤3.6mA), with programmable options
Configuration methodPanel key + LCD display (intellectual), or PC Software implementation USB Configuration;parameters are electrically saved; input can be set Range, Output Range, zero points/plenour fine-tuning
DisplayOptional 2.4 inch LCD, cycle display input current, output 1, output 2 & percentage (smart Display type)
Power supplyDC 20–35V (Performance 24V) or AC 85–265V (fluent type, internal switch power); power consumption ≤2.5W
Mounting35mm standard DIN rail carcass; thickness 18mm (One input, two outputs)
WiringPlugged screws (2.5mm2), input/output/power partitioning
Operating environmentTemperature -20–+60℃, relative humidity ≤95%RH (Non-condensing)
Overall dimensions18 × 110 × 118mm (wide × high × deep)
Instrument weight0.15kg
Applicable standardsGB/T 17626 (EMC)/ IEC 61000-6-2 / GB/T 18271 (process measurement and control device performance assessment)
Typical applicationsDistribution and signal distribution of pressure/ differential pressure / level /temperature transmitter in installations such as oil, chemicals, electricity, metallurgical and water treatment; especially suitable for the same location to be supplied at the same time DCS separate from the local recorder or safety instrument system
Product featuresPower distribution is integrated with signal distribution, free of additional distribution modules and distributors; two-way output is isolated from each other, short-circuited or adjoining the other; HART transparency, smart Transmitter Configuration is exempted from the scene; short-circuit limit flow protection, on-site connection failure does not damage the equipment; distribution voltage is fine-tuned and adapted to long-range cable pressure reduction

Product selection

VISCON-DIS-100
Channel configuration
CodeChannel configuration
C1One input, one output
C2One input, two outputs (Standard, separate roads)
C3Two inputs, two outputs
Input Method
CodeInput Method
I1Second-line transmitter (with 24V distribution)
I2Three-wire / Four-wire (without electricity)
I3/ Without electricity toggle
Output signal
CodeOutput signal
O1Two roads 4–20mA (Standard)
O2Two roads 1–5V
O34–20mA + 1–5V
O4Two roads 4–20mA + Alarm
Accuracy class
CodeAccuracy class
A1±0.1%FS (Standard)
A2±0.2%FS (Economy type)
A3±0.05%FS (high Accuracy, order)
Transmitter supply capacity
CodeTransmitter supply capacity
P124V / 30mA (Standard)
P224V / 50mA (high power)
P322–26V adjustable / 30mA
Display and configuration
CodeDisplay and configuration
D1no display, PC Configuration
D2LCD display + Key Configuration (Intelligence)
D3D2 + USB Configuration with data export
Power supply
CodePower supply
S1DC 24V(20~35V)
S2AC 85–265V broad pressure
S3DC 24V redundant double-track input
Special function
CodeSpecial function
F1Basic Type
F2Programable on/offline
F3F2 + output block adjustable (0–30s)
F4F3 + square root flow conversion

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
VISCON-DIS-100 Smart Transmitter Power Supply / Distributor