Smart -way display adjusterClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-DIS-150
Smart -way display adjuster
Smart -way display adjuster, smart -way display adjuster
01
Classification: Smart -way display regulator
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-DIS-150 |
|---|---|
| Product function | One instrument collects and display 4 backway measurements, each with an independent PID operation and output, which corresponds to the integration of 4 single circuit adjuster into a shell 96×96; a small device suitable for surface space tension and concentration of points |
| Input channels | 4 road independently and in isolation from one another (isolation voltage 500VAC); 4 road can be fully invested or used only 1–3 road |
| Input type | RTD Pt100 / Pt1000 / Cu50 / Cu100; thermocouple K / E / J / T / N / S / R / B; direct current 4–20mA / 0–20mA; direct current voltage 1–5V / 0–10V / ±100mV; electrical resistance 0–400Ω |
| Measurement accuracy | ±0.2%FS (direct flow signal); RTD ±0.2%FS (Pt100 potable ±0.1℃); thermocouple ±0.2%FS, separate channels cold junction compensation (error ±1℃) |
| Sample cycle | 100ms (4 channel aggregate); 16 bit A/D conversion; stand-alone digital filters per channel, level of strength 0–15 available |
| Loop functions | Every road is independent. configuration Yes: only display, display + high and low limits alarm, display + PID Reconciliation, display + Transmitter output One of four modes; usable in the same table |
| PID parameters | 4 We're going back to our separate homes. P (0.1–9999.9%), I (1–9999s), D (0–9999s); micro-divide line, credit limit, anti-saturation; each circuit can be started separately Auto-tuning |
| Output Configuration | Most 4 Road. 4–20mA (loading) ≤500Ω), 4 Places ON/OFF, 4 Proportion of road time (%) PWM, cycle 1–120s;output type specified by turnback |
| Channel calculations | Supporting inter-channel calculations as virtual item 5 display: A-B margin, average, maximum, minimum, ultra-point statistics; for temperature differential monitoring (entry water temperature difference) and multi-point average control |
| Display unit | Standard Configure 4 Double Lines 4 bits LED Digital tube (upline per group) PV Down row. SV, switchable display MV); one for each group 21 (a) Segments of light poles; optional 5 Inch colour screen, four partitions side by side Display Numerical and trend curves |
| Function Alarm | 2–4 group alarm (ceiling, floor, high and low limits, deviation, block, over range); relay output 4 road or 8 road (250VAC/2A), can be Alarm Configuration at any one of the circuits |
| Manual / automatic changeover | Manual / automatic no-disturb transition per circuit; directly set output percentages on manual and toggle instant output maintained |
| Communication interface | RS485 (Modbus RTU from station) standard; optional Ethernet or USB interface 4 SV, PID parameters and Alarm status |
| Power supply | AC 85–265V (50/60Hz), power ≤8VA; optional DC 24V power supply |
| Enclosure and protection | Disk assembly 96×96mm, front plate protection IP65, back end IP20; plug-in endpoint, four-way endpoint partition |
| Panel cutout dimensions | 92 × 92mm (wide × high), insertion depth ≤110mm |
| Instrument weight | 0.6kg |
| Applicable standards | JB/T 8214 (industrial process control regulator) / GB/T 17626 (EMC) / Reference JJG 617 (digital temperature indicator regulator Verification regulation) |
| Typical applications | Small heat exchange units, hot and wet rooms, multi-area temperature control in test boxes, multi-part cartridges in retrospect machines, coating of dry threads, water treatment plus adjustments pH multiple-routing controls |
| Product features | 4 return route, with approximately three-quarters reduction in desktop occupancy, and simplified connection and spare parts; back-to-back electrical separation, with no impact on the rest of the circuits due to sensor failure; Channel calculations saves a thermometer; each circuit output pattern can be different, with a current valve and solid-state relay inside it. |
Product selection
VISCON-DIS-150| Code | Input type |
|---|---|
| I1 | RTD Pt100 / Cu50 |
| I2 | Thermocouple K/E/J/T |
| I3 | Thermocouple S/R/B |
| I4 | 4~20mA / 1~5V |
| I5 | Almighty input (total signal, Standard) |
| Code | Measuring span |
|---|---|
| A1 | -200~+600℃ |
| A2 | 0~+1300℃ |
| A3 | 0~+1800℃ |
| A4 | -0.1–0–60MPa (with Transmitter) |
| A5 | 0–9999 General Engineering Unit |
| A6 | Individual circuits are assigned (Specify when ordering) |
| Code | Loop functions |
|---|---|
| C1 | 4 display + Alarm |
| C2 | 4 return road display + 4 PID reconciliation Standard |
| C3 | 2 Road PID + 2 Road only Display |
| C4 | 4 Return + Channel calculations (margin / average / minimum) |
| Code | Output Type |
|---|---|
| O1 | 4 Road 4–20mA |
| O2 | 4 ON/OFF (band Hysteresis) |
| O3 | 2 Road 4–20mA + 2 |
| O4 | 4 road time ratio (PWM, cycle available) |
| Code | Display configuration |
|---|---|
| D1 | 4 double row 4 LED (Standard) |
| D2 | 4 double row LED + 4 21 sector light column |
| D3 | 5 inch colour screen four partitions (digit + trend) |
| Code | Alarms and relays |
|---|---|
| P1 | 4 path relay (250VAC/2A) |
| P2 | 8 path relay (250VAC/2A) |
| P3 | 8 repeater + block / Super Range / Sensor short circuit protection |
| Code | Communication interface |
|---|---|
| T1 | RS485(Modbus RTU) |
| T2 | RS485 + Ethernet |
| T3 | RS485 + USB (U disc export record) |
| Code | Power supply |
|---|---|
| V1 | AC 220V(85~265V) |
| V2 | DC 24V |
| V3 | Double power (AC + DC automatic switch) |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us