TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-DIS-200 |
|---|---|
| Product function | 8–64 spot-by-point Display and Alarm will be automatically tested in sequence, and will be replaced by a manual spot-by-point copying form; and will be capable of lock-in, Alarm memory and Channel calculations, Optional with Control output closed loop control for focus sites |
| Scan points | Standard 8 Dot. optional 16 / 24 / 32 / 64 dots; all stations share a high set accuracy A/D and cold junction compensation, by low thermoelectric EMF Scanning for change of concern (remote) thermoelectric EMF ≤0.5μV) |
| Input type | RTD Pt100 / Pt1000 / Cu50 / Cu100; thermocouple K / E / J / T / N / S / R / B; direct current 4–20mA / 0–20mA; direct current voltage 1–5V / 0–10V; resistance 0–400Ω; point-by-point type may vary (Configuration) |
| Measurement accuracy | ±0.2%FS (straight current signal); RTD ±0.2%FS (Pt100 chiev ±0.1℃); thermocouple ±0.2%FS cold junction compensation error ±1℃; scanned switch exposure to electrical resistance ≤50mΩ |
| Scanning speed | Stay 0.2–5.0s is available; full circuit cycle automatically calculated and Display; two modes of running can be used for travelling/ fixed points, moving manually or typing points directly at fixed points |
| Display unit | Standard Double Platoon 4 bits LED: Up row display Bits (Pilots) P01–P64 Downstairs display (a) the measure value and unit of the point, with additional point state indications; optional 5 Inch liquid crystal, side screen. display 8–16 Sticky Charts and Hypermarks |
| Function Alarm | Every point 2 Group alarm (ceiling, floor), total 128 Groups; alarm Delay 0–999s available; available alarm Memories, heads up. alarm Memory (recording points and moments above limit); relay output 8 Lou, Configurable For any reason. Alarm |
| Channel calculations | Supports maximum, minimum, average, ultra-point statistics for all sites, as well as margin values of any two points (e.g. temperature differential for the chamber); calculation results can be used as virtual points Display and Alarm |
| Control output | Optional 1–4 road 4–20mA or bit output performed PID reconciliation of assigned points; the rest of the stations remain on the road Display |
| Recording functions | Optional inline 8GB to record all points of historical data at set intervals, and to support point-to-point query curves and export CSV |
| Print Interface | Optional RS232 / TTL print interface to support time printing (class/day) and call printing (current mobile value + Alarm state), with a microstring printer |
| Communication interface | RS485 (Modbus RTU from station) standard; optional Ethernet; all points can be read on a one-time basis, round ≤1s |
| Power supply | AC 85–265V (50/60Hz It's a lot of work. ≤15VA; optional DC 24V |
| Enclosure and protection | Disk assembly 160×80mm transverse structure, front plate protection IP65, back line end IP20; spot endpoints arranged by serial-numbered partitions with markers |
| Panel cutout dimensions | 152 × 76mm (wide × high), insertion depth ≤190mm |
| Instrument weight | About 1.3kg (32 point configuration) |
| Applicable standards | JB/T 8214 (Industrial Process Control Condensator) / GB/T 34037 / GB/T 17626 (EMC) / Reference JJG 617 (Digital Temperature Indicator Verification regulation) |
| Typical applications | Thermal treatment furnaces and multipoint furnace temperature monitoring, storage tank temperature inspections, electrical and transformer round-group temperature monitoring, bakery multi-point cooling, kiln cross-section temperature distribution, cooling tanks and grain silo temperature monitoring |
| Product features | A scanned circuit covers dozens of points at a unit cost well below multiple one-way circuits; point-by-point Configuration, Thermocouple and RTD may be mixed; memory Alarm is available for ex post facto determination beyond the threshold; point differentials are calculated to yield temperature differentials directly and extra meters are saved |
Product selection
VISCON-DIS-200| Code | Number of scan points |
|---|---|
| P08 | 8 point |
| P16 | 16 point |
| P24 | 24 point |
| P32 | 32 point |
| P64 | 64 point (order) |
| Code | Input type |
|---|---|
| I1 | RTD Special (Pt100 / Cu50) |
| I2 | Thermocouple Special (K/E/J/T/N) |
| I3 | Thermocouple K/E/J/T/N/S/R/B full score |
| I4 | 4~20mA / 1~5V |
| I5 | Almighty input, point by point Configuration (Standard) |
| Code | Scanning speed |
|---|---|
| S1 | Every dot 1.0s (Standard) |
| S2 | 0.5s |
| S3 | 0.2s per dot (rapid tour) |
| S4 | 2–5s per dot (low power and long life) |
| Code | Display configuration |
|---|---|
| D1 | Double row 4 LED (point sign + measurements Standard) |
| D2 | Double Platoon LED + Point Status Indicator |
| D3 | 5 inch liquid crystal, 8–16 stick + ultra-limit mark |
| Code | Alarms and relays |
|---|---|
| A0 | Unrelay output (panel Alarm only) |
| A4 | 4 routing relays |
| A8 | 8 road relay (Configurable for one thing) |
| Code | Records and Printing |
|---|---|
| M0 | No records, no printing |
| M1 | Inline 8GB log (checkable curve, guide CSV) |
| M2 | 8GB Records + micro-drive interface (time/call printing) |
| Code | Control output |
|---|---|
| C0 | No Control output (pure inspection Display) |
| C1 | 1 4–20mA PID output |
| C2 | 2 4–20mA PID output |
| C4 | 4 4–20mA PID output |
| Code | Communication interface |
|---|---|
| T1 | RS485(Modbus RTU) |
| T2 | RS485 + Ethernet |
| T3 | RS485 + Ethernet + USB export |