Smart Double-Input Display ConsoleClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-DIS-250
Smart Double-Input Display Console
Smart Double-Input Display Condigent, Smart Double-Induced Adgulator
01
Classification: Smart Double Enter Displaying Console
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-DIS-250 |
|---|---|
| Product function | Simultaneous access to two-way sensors, with the exception of Display, respectively, to complete the calculation of the margin, averages, and values, margin, openings, etc. in the table, and to participate in Alarm and reconciliations using the results of the calculations; one table replaces two Transmitter, plus a combination of an operator, with a simplified connection and spare parts |
| Input channels | 2 It's a freeway, it's a separate route. 500VAC; the two paths can be different (e.g., the road) Pt100 All the way. 4–20mA) On the road to independence Configuration Range with decimal points |
| Input type | RTD Pt100 / Pt1000 / Cu50 / Cu100 (II, III, four-wire); thermocouple K / E / J / T / N / S / R / B; direct current 4–20mA / 0–20mA; direct current voltage 1–5V / 0–10V / ±100mV; electrical resistance 0–400Ω |
| Measurement accuracy | ±0.2%FS (Darling signal); RTD ±0.2%FS, Pt100 Yes. -50–+200℃ Koda. ±0.1℃; thermocouple ±0.2%FS Also cold junction compensation (Errores) ±1℃); 16 bits A/D,sampling cycle 100ms |
| Calculation functions | Difference A-B (can be countersigned for B-A), mean, and values, maximum / minimum, margin A/B, open (differential pressure flow), temperature and pressure compensation (pressure across the way); operator objects can be selected between A, B, or the operational value can be locked to maximum value |
| Calculation accuracy | Additional error ≤±0.05%FS; margin display range 0.001–9999, with engineering units; margin Display negative, maximum Display minus |
| Display unit | Double Platoon 4 bits LED: Up row display Operation results, lower rows display A or B Yeah. configurable Yes. A, B Double-channel side by side; with double-luminum columns, with two columns indicated separately A, B % of margin changes |
| Display resolution | 0.001 / 0.01 / 0.1 / 1 4 Optional, automatically or manually specified by Range operation, so that the margin is zero at the end of the hour |
| Function Alarm | Three alarm groups, each independently assigned to A, B, or the calculated value. Modes include high, low, high/low, deviation, open sensor, and overrange. Three relay outputs (250 V AC / 2 A), with 0–999 s delay and 0–100% hysteresis. |
| Control output | 1 road PID output, control object is preferred A B or one of the operating values; output type 4–20mA linear, time PWM (cycle 1–120s) or bit ON/OFF 3 |
| Transmitter output | Optional 2 road 4–20mA corresponding to A and B (or A and operating value), load ≤500Ω; and control output independent of each other and capable of delivering PLC at the same time as the recorder |
| Communication interface | RS485 (Modbus RTU from station); read A, B, calculate value and alarm state, read and write PID parameters and set values |
| Power supply | AC 85–265V (50/60Hz), power ≤6VA; optional DC 24V; optional 24VDC feed output for Two-wire Transmitter |
| Enclosure and protection | Disk assembly 96×96mm, front plate protection IP65, back line end IP20; plugged ender, two-way input of ender partition layout with marking |
| Panel cutout dimensions | 92 × 92mm (wide × high), insertion depth ≤110mm |
| Instrument weight | 0.5kg |
| Applicable standards | JB/T 8214 (industrial process control regulator) / GB/T 17626 (EMC) / Reference JJG 617 (digital temperature indicator regulator Verification regulation) |
| Typical applications | Water temperature differentials for heat exchange stations and caloric measurements, temperature differential surveillance of the reservoirs in cold storage, pressure difference between filters and heat exchangers, average room temperature at two dots, Level (two Flange or double input), control of the acid concentration margin, double flow ratio |
| Product features | The margin is calculated within the table without having to bypass PLC and return display, save a program and an operator; the two paths input type, but the temperature can be directly matched; the calculation results can be associated with alarm, and PID, and the temperature differentials can drive the direct valve action; the two columns allow A, B, and the two curves can be visible intuitively |
Product selection
VISCON-DIS-250| Code | Calculation functions |
|---|---|
| F1 | Margin A-B (reverseable) |
| F2 | Mean / and value / minimum maximum value |
| F3 | Value A/B |
| F4 | Open-source calculation (Differential pressure flow) |
| F5 | Temperature and pressure compensation (temperature + pressure) |
| F6 | All above Optional (Standard) |
| Code | Group Input type |
|---|---|
| I1 | Double RTD (Pt100 etc.) |
| I2 | Double Thermocouple |
| I3 | RTD + Thermocouple |
| I4 | Double 4–20mA / 1–5V |
| I5 | Configuration (Standard) |
| Code | Display configuration |
|---|---|
| D1 | Two rows 4 LED |
| D2 | Two rows LED + Double-light column (Standard) |
| D3 | Two rows LED + Double-light column + Operating value read in full |
| Code | Control output |
|---|---|
| C0 | No Control output (pure Display operation) |
| C1 | 1 Road 4–20mA PID |
| C2 | 1 PWM |
| C3 | 1 ON/OFF (band Hysteresis) |
| Code | Transmitter output |
|---|---|
| O0 | Transmitter output |
| O1 | 1 Road 4–20mA |
| O2 | 2 road 4–20mA (A + B or A + operating value Standard) |
| Code | Alarms and relays |
|---|---|
| A2 | 2 group alarm / 2 repeater |
| A3 | 3 group alarm / 3 repeater (Standard) |
| A4 | 4 group alarm / 4 repeater |
| Code | Communication interface |
|---|---|
| T0 | Communication |
| T1 | RS485(Modbus RTU) |
| T2 | RS485 + Ethernet |
| Code | Power supply |
|---|---|
| V1 | AC 220V(85~265V) |
| V2 | DC 24V |
| V3 | AC 220V + 24V feed output |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us