Smart Digital Display ModemClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-DIS-300
Smart Digital Display Modem
Smart Digital Display Moderate, Smart Digital Display Moderate
01
Classification: Smart Number Displaying Concorter
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-DIS-300 |
|---|---|
| Product function | Universal single circuit display reconcile: all-round, double row display, PID or bit output covering most of the single-point control settings such as temperature, pressure, flow, Level; replacement of the main engine of the old ring-like indicator and the simple thermometer, connect to Panel cutout dimensions using traditional specifications |
| Input type | RTD Pt100 / Pt1000 / Cu50 / Cu100 (II, III, four-wire); thermocouple K / E / J / T / N / S / R / B / WRe3-WRe25; direct current 4–20mA / 0–20mA; direct current voltage 1–5V / 0–10V / ±100mV / ±1V; electrical resistance 0–400Ω; frequency 0–10kHz (flowing sensor) |
| Measurement accuracy | ±0.2%FS (standard); optional ±0.1%FS High accuracy version; Pt100 can reach ±0.1℃ between -50–+200℃; 16 bit A/D, sampling cycle 100ms |
| Display unit | Double Platoon 4 bits LED: Up row PV (Bywords high) 13mm Next row. SV; optional Single-row large character type (high font) 20mm, suitable for remote viewing; right 4 The percentage of the output of the sector light column indicating a state of heating or cooling is clear |
| Digital filter | 0–15 class filter strength is set, coupled with 1–100 double average, inhibiting the site Variable frequency drive from beating at the end due to contact interference, while maintaining the required response speed |
| PID parameters | P 0.1–9999.9%, I 1–9999s, D 0–9999s; with a micro-score lead, a saturation of points and resistance; AT Auto-tuning with a relay feedback method, which can be fixed in a single instance and can be set manually on an empirical basis |
| Output Configuration | Four optional 1 1 4–20mA linear output (load ≤500Ω); 2 time ratio PWM (cycle 1–120s, contact 250VAC/2A); 3 bits ON/OFF (hysteresis 0–100% available); 4 heating + cooling Dual output (dead area available for two-way temperature control) |
| Function Alarm | 2–4 alarm optional: upper limit, lower limit, high and low limits, deviation, block, over range; relay capacity 250VAC/2A; each group can have 0–999s delay with 0–100% Hysteresis to avoid short-lived fluctuations in opening doors, inputs, etc. |
| Transmitter output | Optional 1 road 4–20mA transmitter output (corresponding PV), independent of control output, can be used for recorders or PLC collection at the same time |
| Communication interface | Optional RS485 (Modbus RTU from the station); remote reading and writing settings, PID parameter and Alarm Configuration for integration of equipment sets |
| Power supply | AC 85–265V (50/60Hz It's a lot of work. ≤5VA; optional DC 24V; optional 24VDC Feeding output (for Two-wire Transmitter Save one switch. |
| Enclosure and protection | Disk assembly, front plate protection IP65 (optional IP66), back end IP20; plug-in ender, no table to open |
| Panel cutout dimensions | 92 × 92mm (96×96 Type)/ 68 × 68mm (72×72 Type)/ 45 × 92mm (48×96 This post is part of our special coverage Syria Protests 2011. insertion depth ≤100mm |
| Instrument weight | About 0.45kg (96×96) |
| Applicable standards | JB/T 8214 (industrial process control regulator) / GB/T 17626 (EMC) / Reference JJG 617 (digital temperature indicator regulator Verification regulation) |
| Typical applications | Electric furnaces and ovens temperature control, retrofitting and extruding drums, hot water and conductor heating systems, pressure and single point control Level, flow single-ring regulation, test and incubators, food fungicide and fermentation temperature, packaging machine heat seals |
| Product features | If you can enter one, the customer needs only one spare. model; AT auto-tuning A high success rate, so debugging does not have to be done over and over again; heating and cooling dual output Processes that require two-way temperature control can be covered; optional 24V I'm not sure if I'm going to do this. two-wire transmitter There is no need for alternative power distribution; 96×96 The openings and the traditional instruments are common, and retrofits are directly interchangeable. |
Product selection
VISCON-DIS-300| Code | Overall dimensions |
|---|---|
| S96 | 96 × 96mm (Standard) |
| S72 | 72 × 72mm |
| S4896 | 48 × 96mm (vertical) |
| S9648 | 96 × 48mm (twice) |
| Code | Input type |
|---|---|
| I1 | RTD RTD |
| I2 | Thermocouple TC |
| I3 | 4~20mA / 1~5V |
| I4 | Frequency 0–10kHz |
| I5 | Almighty input (total signal, Standard) |
| Code | Measurement accuracy |
|---|---|
| P1 | ±0.2%FS (Standard) |
| P2 | ±0.1%FS Accuracy |
| Code | Output Type |
|---|---|
| O1 | 4–20mA linear output |
| O2 | Time PWM |
| O3 | Bits ON/OFF (with Hysteresis) |
| O4 | Heat + cooling Dual output |
| Code | Number of alarms |
|---|---|
| A2 | Group 2 Alarm |
| A3 | 3 group Alarm (Standard) |
| A4 | Group 4 Alarm |
| Code | Transmitter output |
|---|---|
| B0 | Transmitter output |
| B1 | 1 Road 4–20mA transmission (PV) |
| Code | Communication interface |
|---|---|
| T0 | Communication |
| T1 | RS485(Modbus RTU) |
| Code | Power supply and transmitter excitation |
|---|---|
| V1 | AC 220V(85~265V) |
| V2 | DC 24V |
| V3 | AC 220V + 24V feed output |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us