Precision digital pressureometerClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

VISCON-DP-100

Precision digital pressureometer

Precision digital pressureometers, precision digital pressureometers

01

Classification: Precision numerical pressureometer

02

Check configuration based on field work

⁇ Return to precise numerical pressureometer classification

TECHNICAL SPECIFICATIONS

Technical specifications

VISCON-DP-100

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelVISCON-DP-100
Operating principleHigh accuracy Pressure sensitivity component (diffused silicon piezoresistive / monocrystalline silicon sonry) output electrical signals converted from 24 A/D microprocessor to temperature reimbursement, non-linear correction and zero point tracking, direct in digital form Display pressure value
Pressure typeGauge pressure (G), absolute pressure (A), differential pressure (D), vacuum and compound range (-100kPa–0)
Pressure rangeMicropressure 0–10/60/100kPa; low pressure 0–600kPa/1.6MPa; medium pressure 0–6MPa/10MPa; high pressure 0–25MPa/40MPa/60MPa; compound -0.1–0–2.5MPa; differential pressure 0–10kPa/60kPa/1.6MPa; can order at any time Range
Accuracy class0.02%FS (standard, high-accuracy type), 0.05%FS, 0.1%FS; annual stability ≤0.02%FS /year
Resolution6 display 0.001%FS
Overload capacity1.5 times FS non-damage; 2 FS short time (≤10s) not invalid
Display unitsPa, kPa, MPa, bar, mbar, psi, kgf/cm2, mmH2O, mmHg, inH2O, atm Wait. 12 Seeds, one key switch
Display type5.5 " Colour TFT LCD, double row display (Main pressure + by-product/ percentage/peak); backlight Adjustable contrast
Measurement functionPeak / valley maintenance, average, real-time pressure / percentage error screen Display, pressure check leak (time and rate reduction calculation), unit conversion, zero point decoupling
Electrical signal measurementDirect current 0–25.000mA (accuracy 0.02%RD+0.005%FS), direct current voltage 0–30.000VDC; usable for signal source/measurement 4–20mA
Loop powerInternal DC 24V Loop power supply (with short-circuit protection) which provides direct power to pressure Transmitter and simultaneous reading of currents, achieving Transmitter one Verification
Pressure switch testAutomatically capture switch action points (up-to-peer/down-to-peer) and switch points, repeat the average three times
Data managementInternal storage ≥1000 group measurement log (with time stamp) to support U dispatch CSV/Excel; optional Bluetooth/ WiFi upload to mobile phone or computer
Communication interfaceRS232 (standard)/ USB (standard); optional RS485 Bluetooth. 5.0, WiFi Modules
Power supplyChargeable lithium batteries 7.4V / 4000mAh, working continuously ≥20h (to turn off backlight); equipped with AC 220V adapter charge to support side load; Optional Intrinsically safe batteries
Wetted materials316L stainless steel film and membrane (standard); optional Hastelloy C276, tantalum coating (corrosive media)
Process connectionM20×1.5 female thread (standard); optional G½, G¼, 1/4NPT, M14×1.5, DN16 fast lock-in
Operating environmentTemperature 0–50℃, relative humidity ≤90%RH; storage temperature -20–+70℃; no powerful vibration, no corrosive gas
Ingress protectionIP54 (standard); optional IP65 (dustproof spray)
Overall dimensionsAbout 220 × 120 × 62mm (with handbands and no no connects)
Instrument weightAbout 1.2kg (including batteries)
Applicable standardsJJG 875 Digital Pressureometer/ JJG 882 Pressure transmitter / JJF 1008 Pressure Measurement Terminology and Definitions / GB/T 17626 (EMC)
Typical applicationsPressure table, pressure Transmitter, pressure switch, on-site check-up of pressure controllers against online, high Accuracy pressure Standard long-term
Product featuresAccuracy 0.02%FS, replacing 0.05 and below standard table; pressure and current screens are double visible, one transmitter complete verification; interior 24V loop power supply & leak detection; lithium 20h and above do not need external power; full Chinese menu with gloves to operate

Product selection

VISCON-DP-100
Pressure type
CodePressure type
P1Gauge pressure (G)
P2Absolute pressure (A)
P3Differential pressure (D)
P4Vacuum /complex(-100kPa–0 or -0.1–2.5MPa)
Pressure range
CodePressure range
R10–10kPa (micropressure)
R20~60kPa
R30~600kPa
R40~1.6MPa
R50~6MPa
R60~25MPa
R70~60MPa
R8Combination -0.1–0–2.5MPa
Accuracy class
CodeAccuracy class
A10.02%FS (High-accuracy type)
A20.05%FS
A30.1%FS
Function Configuration
CodeFunction Configuration
F1Basic type (pressure measurement)
F2Pressure + 4–20mA electron (include 24V Loop power supply)
F3Pressure + current voltage + pressure switch test
F4F3 + HART Communication (with Transmitter Configuration)
Process connection
CodeProcess connection
T1M20×1.5 Female thread (Standard)
T2G½ Female thread
T31/4NPT Female thread
T4DN16 fast lock-in
Wetted materials
CodeWetted materials
M1316L Stainless steel (Standard)
M2Hastelloy C276
M3316L + tantalum coating
Communication and storage
CodeCommunication and storage
C1RS232 + USB (Standard)
C2C1 + RS485
C3C1 + Bluetooth 5.0
C4C1 + WiFi (networking/twilight)
Power supply and protection
CodePower supply and protection
B1Lithium Battery + AC adaptor, IP54
B2Lithium Battery + AC adaptor, IP65
B3Intrinsically safe type Battery (Ex ia II C T4), IP65

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
VISCON-DP-100 Precision Digital Pressure Gauge