Precision digital pressureometerClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-DP-100
Precision digital pressureometer
Precision digital pressureometers, precision digital pressureometers
01
Classification: Precision numerical pressureometer
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-DP-100 |
|---|---|
| Operating principle | High accuracy Pressure sensitivity component (diffused silicon piezoresistive / monocrystalline silicon sonry) output electrical signals converted from 24 A/D microprocessor to temperature reimbursement, non-linear correction and zero point tracking, direct in digital form Display pressure value |
| Pressure type | Gauge pressure (G), absolute pressure (A), differential pressure (D), vacuum and compound range (-100kPa–0) |
| Pressure range | Micropressure 0–10/60/100kPa; low pressure 0–600kPa/1.6MPa; medium pressure 0–6MPa/10MPa; high pressure 0–25MPa/40MPa/60MPa; compound -0.1–0–2.5MPa; differential pressure 0–10kPa/60kPa/1.6MPa; can order at any time Range |
| Accuracy class | 0.02%FS (standard, high-accuracy type), 0.05%FS, 0.1%FS; annual stability ≤0.02%FS /year |
| Resolution | 6 display 0.001%FS |
| Overload capacity | 1.5 times FS non-damage; 2 FS short time (≤10s) not invalid |
| Display units | Pa, kPa, MPa, bar, mbar, psi, kgf/cm2, mmH2O, mmHg, inH2O, atm Wait. 12 Seeds, one key switch |
| Display type | 5.5 " Colour TFT LCD, double row display (Main pressure + by-product/ percentage/peak); backlight Adjustable contrast |
| Measurement function | Peak / valley maintenance, average, real-time pressure / percentage error screen Display, pressure check leak (time and rate reduction calculation), unit conversion, zero point decoupling |
| Electrical signal measurement | Direct current 0–25.000mA (accuracy 0.02%RD+0.005%FS), direct current voltage 0–30.000VDC; usable for signal source/measurement 4–20mA |
| Loop power | Internal DC 24V Loop power supply (with short-circuit protection) which provides direct power to pressure Transmitter and simultaneous reading of currents, achieving Transmitter one Verification |
| Pressure switch test | Automatically capture switch action points (up-to-peer/down-to-peer) and switch points, repeat the average three times |
| Data management | Internal storage ≥1000 group measurement log (with time stamp) to support U dispatch CSV/Excel; optional Bluetooth/ WiFi upload to mobile phone or computer |
| Communication interface | RS232 (standard)/ USB (standard); optional RS485 Bluetooth. 5.0, WiFi Modules |
| Power supply | Chargeable lithium batteries 7.4V / 4000mAh, working continuously ≥20h (to turn off backlight); equipped with AC 220V adapter charge to support side load; Optional Intrinsically safe batteries |
| Wetted materials | 316L stainless steel film and membrane (standard); optional Hastelloy C276, tantalum coating (corrosive media) |
| Process connection | M20×1.5 female thread (standard); optional G½, G¼, 1/4NPT, M14×1.5, DN16 fast lock-in |
| Operating environment | Temperature 0–50℃, relative humidity ≤90%RH; storage temperature -20–+70℃; no powerful vibration, no corrosive gas |
| Ingress protection | IP54 (standard); optional IP65 (dustproof spray) |
| Overall dimensions | About 220 × 120 × 62mm (with handbands and no no connects) |
| Instrument weight | About 1.2kg (including batteries) |
| Applicable standards | JJG 875 Digital Pressureometer/ JJG 882 Pressure transmitter / JJF 1008 Pressure Measurement Terminology and Definitions / GB/T 17626 (EMC) |
| Typical applications | Pressure table, pressure Transmitter, pressure switch, on-site check-up of pressure controllers against online, high Accuracy pressure Standard long-term |
| Product features | Accuracy 0.02%FS, replacing 0.05 and below standard table; pressure and current screens are double visible, one transmitter complete verification; interior 24V loop power supply & leak detection; lithium 20h and above do not need external power; full Chinese menu with gloves to operate |
Product selection
VISCON-DP-100| Code | Pressure type |
|---|---|
| P1 | Gauge pressure (G) |
| P2 | Absolute pressure (A) |
| P3 | Differential pressure (D) |
| P4 | Vacuum /complex(-100kPa–0 or -0.1–2.5MPa) |
| Code | Pressure range |
|---|---|
| R1 | 0–10kPa (micropressure) |
| R2 | 0~60kPa |
| R3 | 0~600kPa |
| R4 | 0~1.6MPa |
| R5 | 0~6MPa |
| R6 | 0~25MPa |
| R7 | 0~60MPa |
| R8 | Combination -0.1–0–2.5MPa |
| Code | Accuracy class |
|---|---|
| A1 | 0.02%FS (High-accuracy type) |
| A2 | 0.05%FS |
| A3 | 0.1%FS |
| Code | Function Configuration |
|---|---|
| F1 | Basic type (pressure measurement) |
| F2 | Pressure + 4–20mA electron (include 24V Loop power supply) |
| F3 | Pressure + current voltage + pressure switch test |
| F4 | F3 + HART Communication (with Transmitter Configuration) |
| Code | Process connection |
|---|---|
| T1 | M20×1.5 Female thread (Standard) |
| T2 | G½ Female thread |
| T3 | 1/4NPT Female thread |
| T4 | DN16 fast lock-in |
| Code | Wetted materials |
|---|---|
| M1 | 316L Stainless steel (Standard) |
| M2 | Hastelloy C276 |
| M3 | 316L + tantalum coating |
| Code | Communication and storage |
|---|---|
| C1 | RS232 + USB (Standard) |
| C2 | C1 + RS485 |
| C3 | C1 + Bluetooth 5.0 |
| C4 | C1 + WiFi (networking/twilight) |
| Code | Power supply and protection |
|---|---|
| B1 | Lithium Battery + AC adaptor, IP54 |
| B2 | Lithium Battery + AC adaptor, IP65 |
| B3 | Intrinsically safe type Battery (Ex ia II C T4), IP65 |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us