Smart Flow ImpressorClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

VISCON-FT-100

Smart Flow Impressor

Smart flow calculator, smart flow calculator

01

Classification: Smart flow calculator

02

Check configuration based on field work

⁇ Returning Smart Flow Calculator Classification

TECHNICAL SPECIFICATIONS

Technical specifications

VISCON-FT-100

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelVISCON-FT-100
Product functionCollecting flow signals (Differential pressure also takes pressure and temperature) to convert and accumulate in real time the corresponding Compensation model work or profile flows, output Instantaneous flow, Totalized flow and heat; support Batch control with batch materials, replacing manual copying tables and manual calculations
Input configuration3 road input: Main volume input + temperature input + pressure input; temperature and pressure can be cast only along the way (compensated by one parameter) or not at all (linear flow factor straight)
Flow Input typeDirect current 4–20mA / 0–20mA, direct current 1–5V / 0–10V, pulse 0–10kHz (turbo, elliptical gear, waist wheel), frequency 0–5kHz (vortex, vortex)
Temperature and pressure inputTemperature: Pt100 three-wire thermocouple K/E 4–20mA (with temperature transmitter); pressure: 4–20mA (with pressure Transmitter) Range and engineering units available
Compensation model1 differential pressure (poreboard, nozzle, flat-speed tube, V cones) belt temperature and pressure compensation, calculated by GB/T 2624 flow equation; 2 Linear flow meters (Electromagnetic, Turbo Street, Turbo, Ultrasound) temperature and pressure compensation conversion profile; 3 saturated and overheated vapour IAPWS-IF97 survey; 4 Gas at GB/T 11062 calculated compression factor
Measurement accuracyAccumulation accuracy ±0.2%FS; compensatory error ≤±0.1%; A/D conversion 16 bits; cumulative resolution 0.001 engineering units
Totalizing functionTotal accumulation (6 integer + 3 decimal), class accumulation, day accumulation, month accumulation parallel statistics; power outages maintained ≥10 years; zero by key and automatic recording of zero hour and pre-zero values to prevent error
Low-flow cutoff0–20%FS is available, below the excavation value to accumulate, avoiding zero drift to accumulate significant errors over a long period of time
Batch controlTarget quantity is available (0–999999), pre-arrival (1–10%) pre-arrival stop, with two-track relays exporting to control pumps and valves; support single and circular batches, batch count and cumulative batch count
Display unitDouble Platoon 4 bits LED, click to switch display instantaneous flow, totalized flow temperature, pressure, differential pressure, calorie; optional LCD Multiple Parameters & Screens (In a matter of time) + Cumulative + Temperature + Pressure in four rows simultaneously. Display)
Retransmission and pulse outputs1 road 4–20mA transmitter output (corresponding to instantaneous flow); optional accumulation pulse output (one pulse per unit volume for external counters or PLC high-speed count)
Function AlarmFlows high and low limits, temperature limit, pressure limit, input cut-off, cumulative zero event, Quantification to six classes; relay 2–4 road (250VAC/2A)
Communication interfaceRS485 (Modbus RTU from station) standard; optional Ethernet; optional 4G/NB-IoT remote module uploading instantaneous and cumulative data to energy management platform
Data recordsOptional inline 8GB, saving hour/day/month flow reports, power loss logs and parameter modification logs (including change times and changer numbers)
Power supplyAC 85–265V (50/60Hz) or DC 24V; power ≤6VA; Optional built-in battery backup, continued after power outage Display
Enclosure and protectionDisk assembly 96×96mm, front plate protection IP65, backend IP20; parameters are password-graded (operating level / Configuration)
Panel cutout dimensions92 × 92mm (wide × high), insertion depth ≤110mm
Instrument weight0.5kg
Applicable standardsGB/T 2624 (differential pressure flow measurement throttle device)/ GB/T 11062 (gas heat, density and compression factor)/ JB/T 8214 / Reference JJG 1030 (flow calculator Verification regulation)
Typical applicationsVapour measurements and energy consumption sharing, compressed air and nitrogen measurements, gas and gas measurements, circulatory and refrigerated water cooling, caloric calorie, quantitative vehicles and fillings of finished oils and liquid raw materials
Product featuresInternalized vapour and natural gas material tables, no additional manual calibration of vapour measurements; four sets of cumulative parallel statistics, exported once in the daily newspaper; Batch control pre-positioned with pre-loads and not overloaded; clean-up of trails and parameter logs to facilitate trade settlement and audit traceability

Product selection

VISCON-FT-100
Flow Input type
CodeFlow Input type
F14–20mA / 1–5V (linear flow meters)
F2Pulse 0–10kHz (turbo, gear, waist wheel)
F3Frequency 0–5kHz
F4Differential pressure 4–20mA (with throttles)
F5All above compatible (Universal Flow Input, Standard)
Method of compensation
CodeMethod of compensation
C1No compensation (linear straight)
C2Pressure compensation (single parameters)
C3Temperature + Pressure compensation (Standard)
C4Saturation steam scale reimbursement
C5Overheating steam table compensation (IAPWS-IF97)
C6Gas compression factor compensation (GB/T 11062)
Totalizing and reports
CodeTotalizing and reports
A1Total cumulative
A2Total + class cumulation
A3Total cumulative + class / day / month cumulative (Standard)
A4A3 + Class accumulation (temperature combination)
Batch control
CodeBatch control
Q0Batch control
Q1Single quantity (2 road relay: pump + valve)
Q2Loop lot + Batch count
Q3Q2 + pre-emption (1–10% available)
Display configuration
CodeDisplay configuration
D1Two rows 4 bit LED (toggle Display, Standard)
D2Two rows LED + Accumulated value read in the middle of the word
D3LCD Multiple Parameters Same Screen (Instant/cumulative/temperature/pressure)
Retransmission and outputs
CodeRetransmission and outputs
O11 Road 4–20mA transmission (Instantaneous flow)
O21 Road 4–20mA + cumulation Pulse output
O32 4–20mA + temperature or pressure
Communication and remote transmission
CodeCommunication and remote transmission
T1RS485(Modbus RTU)
T2RS485 + Ethernet
T3RS485 + 4G televised (energy management platform)
T4RS485 + NB-IoT long-distance.
Electricity and records
CodeElectricity and records
V1AC 220V(85~265V)
V2DC 24V
V3AC 220V + built-in battery backup
V4AC 220V + 8GB Data Records

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
VISCON-FT-100 Intelligent Flow Totalizer with Temperature / Pressure Compensation