Smart Flow ImpressorClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-FT-100
Smart Flow Impressor
Smart flow calculator, smart flow calculator
01
Classification: Smart flow calculator
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-FT-100 |
|---|---|
| Product function | Collecting flow signals (Differential pressure also takes pressure and temperature) to convert and accumulate in real time the corresponding Compensation model work or profile flows, output Instantaneous flow, Totalized flow and heat; support Batch control with batch materials, replacing manual copying tables and manual calculations |
| Input configuration | 3 road input: Main volume input + temperature input + pressure input; temperature and pressure can be cast only along the way (compensated by one parameter) or not at all (linear flow factor straight) |
| Flow Input type | Direct current 4–20mA / 0–20mA, direct current 1–5V / 0–10V, pulse 0–10kHz (turbo, elliptical gear, waist wheel), frequency 0–5kHz (vortex, vortex) |
| Temperature and pressure input | Temperature: Pt100 three-wire thermocouple K/E 4–20mA (with temperature transmitter); pressure: 4–20mA (with pressure Transmitter) Range and engineering units available |
| Compensation model | 1 differential pressure (poreboard, nozzle, flat-speed tube, V cones) belt temperature and pressure compensation, calculated by GB/T 2624 flow equation; 2 Linear flow meters (Electromagnetic, Turbo Street, Turbo, Ultrasound) temperature and pressure compensation conversion profile; 3 saturated and overheated vapour IAPWS-IF97 survey; 4 Gas at GB/T 11062 calculated compression factor |
| Measurement accuracy | Accumulation accuracy ±0.2%FS; compensatory error ≤±0.1%; A/D conversion 16 bits; cumulative resolution 0.001 engineering units |
| Totalizing function | Total accumulation (6 integer + 3 decimal), class accumulation, day accumulation, month accumulation parallel statistics; power outages maintained ≥10 years; zero by key and automatic recording of zero hour and pre-zero values to prevent error |
| Low-flow cutoff | 0–20%FS is available, below the excavation value to accumulate, avoiding zero drift to accumulate significant errors over a long period of time |
| Batch control | Target quantity is available (0–999999), pre-arrival (1–10%) pre-arrival stop, with two-track relays exporting to control pumps and valves; support single and circular batches, batch count and cumulative batch count |
| Display unit | Double Platoon 4 bits LED, click to switch display instantaneous flow, totalized flow temperature, pressure, differential pressure, calorie; optional LCD Multiple Parameters & Screens (In a matter of time) + Cumulative + Temperature + Pressure in four rows simultaneously. Display) |
| Retransmission and pulse outputs | 1 road 4–20mA transmitter output (corresponding to instantaneous flow); optional accumulation pulse output (one pulse per unit volume for external counters or PLC high-speed count) |
| Function Alarm | Flows high and low limits, temperature limit, pressure limit, input cut-off, cumulative zero event, Quantification to six classes; relay 2–4 road (250VAC/2A) |
| Communication interface | RS485 (Modbus RTU from station) standard; optional Ethernet; optional 4G/NB-IoT remote module uploading instantaneous and cumulative data to energy management platform |
| Data records | Optional inline 8GB, saving hour/day/month flow reports, power loss logs and parameter modification logs (including change times and changer numbers) |
| Power supply | AC 85–265V (50/60Hz) or DC 24V; power ≤6VA; Optional built-in battery backup, continued after power outage Display |
| Enclosure and protection | Disk assembly 96×96mm, front plate protection IP65, backend IP20; parameters are password-graded (operating level / Configuration) |
| Panel cutout dimensions | 92 × 92mm (wide × high), insertion depth ≤110mm |
| Instrument weight | 0.5kg |
| Applicable standards | GB/T 2624 (differential pressure flow measurement throttle device)/ GB/T 11062 (gas heat, density and compression factor)/ JB/T 8214 / Reference JJG 1030 (flow calculator Verification regulation) |
| Typical applications | Vapour measurements and energy consumption sharing, compressed air and nitrogen measurements, gas and gas measurements, circulatory and refrigerated water cooling, caloric calorie, quantitative vehicles and fillings of finished oils and liquid raw materials |
| Product features | Internalized vapour and natural gas material tables, no additional manual calibration of vapour measurements; four sets of cumulative parallel statistics, exported once in the daily newspaper; Batch control pre-positioned with pre-loads and not overloaded; clean-up of trails and parameter logs to facilitate trade settlement and audit traceability |
Product selection
VISCON-FT-100| Code | Flow Input type |
|---|---|
| F1 | 4–20mA / 1–5V (linear flow meters) |
| F2 | Pulse 0–10kHz (turbo, gear, waist wheel) |
| F3 | Frequency 0–5kHz |
| F4 | Differential pressure 4–20mA (with throttles) |
| F5 | All above compatible (Universal Flow Input, Standard) |
| Code | Method of compensation |
|---|---|
| C1 | No compensation (linear straight) |
| C2 | Pressure compensation (single parameters) |
| C3 | Temperature + Pressure compensation (Standard) |
| C4 | Saturation steam scale reimbursement |
| C5 | Overheating steam table compensation (IAPWS-IF97) |
| C6 | Gas compression factor compensation (GB/T 11062) |
| Code | Totalizing and reports |
|---|---|
| A1 | Total cumulative |
| A2 | Total + class cumulation |
| A3 | Total cumulative + class / day / month cumulative (Standard) |
| A4 | A3 + Class accumulation (temperature combination) |
| Code | Batch control |
|---|---|
| Q0 | Batch control |
| Q1 | Single quantity (2 road relay: pump + valve) |
| Q2 | Loop lot + Batch count |
| Q3 | Q2 + pre-emption (1–10% available) |
| Code | Display configuration |
|---|---|
| D1 | Two rows 4 bit LED (toggle Display, Standard) |
| D2 | Two rows LED + Accumulated value read in the middle of the word |
| D3 | LCD Multiple Parameters Same Screen (Instant/cumulative/temperature/pressure) |
| Code | Retransmission and outputs |
|---|---|
| O1 | 1 Road 4–20mA transmission (Instantaneous flow) |
| O2 | 1 Road 4–20mA + cumulation Pulse output |
| O3 | 2 4–20mA + temperature or pressure |
| Code | Communication and remote transmission |
|---|---|
| T1 | RS485(Modbus RTU) |
| T2 | RS485 + Ethernet |
| T3 | RS485 + 4G televised (energy management platform) |
| T4 | RS485 + NB-IoT long-distance. |
| Code | Electricity and records |
|---|---|
| V1 | AC 220V(85~265V) |
| V2 | DC 24V |
| V3 | AC 220V + built-in battery backup |
| V4 | AC 220V + 8GB Data Records |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us