Programable thermal resistance (thermal voltage) into the separation fenceClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

VISCON-ISO-100

Programable thermal resistance (thermal voltage) into the separation fence

Programable thermal resistance (thermal doll) enters a separation fence, and programmed thermal resistance/thermal doll enters a separation fence

01

Classification: Programable thermal resistance (thermal voltage) input barrier

02

Check configuration based on field work

⁇ Return programmable thermal resistance (thermal voltage) input barrier classification

TECHNICAL SPECIFICATIONS

Technical specifications

VISCON-ISO-100

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelVISCON-ISO-100
Product function- Yes, sir. hazardous area (0 Region/ 1 Region) RTD or thermocouple Signal Passes intrinsic safety isolation After, in safe area Output standard 4–20mA (or) 1–5V The signal. DCS, PLC, Display instrument collection;input Sensor type and Range It can be programmed through software without the need to replace hardware
Explosion protection typeIntrinsic safety Type-associated equipment [T] Ex ia] II C;connectable 0 Region, 1 Region, 2 Sector II A/II B/II C in the explosive gas environment Intrinsically safe type Temperature sensors
Channel configurationStandard one input, one output (1 channel); optional two inputs, two outputs 2 channel is isolated and separated between routes
Input signalRTD: Pt100, Pt1000, Pt10, Cu50, Cu100, Cu53, Ni1000 (Second-line/ three-wire / four-wire); thermocouple: K, E, J, T, N, S, R, B;other possible 0–400Ω Interception input and -10–100mV millivol input
Temperature rangeRTD -200–+850℃; thermocouple -200–+1800℃ (Pressed) sensor type); range The minimum/ceiling can be programmed in any way. range Range ≥50℃
Output signal4–20mA (standard, load ≤500Ω); optional 1–5V (load ≥250kΩ); output corresponds to input linearity
ProgrammingSpecialized configuration software is set by USB/RS485 sensor type, range, open-circuit alarm in direction, output positive/reverse, damping time (0–60s); parameters are detached and saved
Cold junction compensationThermocouple Input Pt1000 cold junction compensation compensation accuracy ±0.5℃; external fixed cold end or shut-down compensation can be set
Conversion accuracy±0.1%FS (23±2℃); temperature drift ≤0.01%FS/℃; ambient temperature -20–+60℃ Full range ≤±0.3%FS
Open-circuit protectionSensor break wire, short-circuit output by default spill (≥22mA) or spill (≤3.6mA) and can output Alarm contact point (Optional)
Isolation performanceThree-way isolation between input, output, and power. Isolation: 1500 V AC for 1 min. Insulation resistance: ≥100 MΩ at 500 V DC. Common-mode rejection: ≥120 dB.
Intrinsic safety parametersUm=250VAC/DC; Uo=26.0V, Io=93mA, Po=0.60W; Co=0.09μF, Lo=2.4mH (II C); II B Environment Co=0.65μF, Lo=8.0mH
Power supplyDC 20–35V (Quota 24V), texture ≤5%; single channel power ≤1.2W, dual channel ≤2.0W; with reverse Overvoltage protection
Response time≤300ms (with filters); damping time programmable 0–60s
Mounting35mm standard DIN rail cards in dense order; single channel thickness 12.5mm, two channels 18mm
WiringPlugged screws (2.5mm2); Hazardous area set with Safe area end subside and distinguished by blue markings
Operating environmentTemperature -20–+60℃, relative humidity ≤95%RH (Non-condensing); suitable for installation in control cabinets
Overall dimensionsSingle channel 12.5 × 110 × 118mm; double channel 18 × 110 × 118mm (wide × high × deep)
Instrument weightAbout 0.12kg (single channel)
Applicable standardsGB 3836.1 Explosive Environment 1 Part: Equipment General Requirements / GB 3836.4 ... 4 Part: Equipment protected by intrinsic safety i / GB/T 17626 (EMC) / IEC 60751 / IEC 60584
Certification requirementsExplosion protection certificate; intrinsically safe system GB 3836.15 Intrinsic safety parameters after accounting
Typical applicationsIn installations with explosive gas environments such as oil, chemicals, gas, pharmaceuticals, on site RTD / thermocouple DCS PLC signalling separation and security isolation; especially suitable for Sensor type or Range on-site alteration and interoperability of spare parts
Product featuresSensor type programmable with Range software, one fence covering all Typical temperature sensors, single spare parts; three-end isolation, strong anti-terrestrial circulation and commo interference; Open-circuit failure direction programmable, interlock logic flexible; thin DIN rail installed, small occupancy of inner cabinet space

Product selection

VISCON-ISO-100
Number of channels
CodeNumber of channels
C1One input, one output (1 channel)
C2Two inputs, two outputs (2 channel, stand alone)
Input type
CodeInput type
T1RTD Input (Pt100/Cu50/Cu100)
T2RTD input (full score, including Pt1000/Ni1000/Cu53)
T3Thermocouple Input (K/E/J/T/N)
T4RTD + Thermocouple programmable (full functionality)
Output signal
CodeOutput signal
O14–20mA (Standard)
O21~5V
O34–20mA + Alarm Touch Output
Accuracy class
CodeAccuracy class
A1±0.1%FS (Standard)
A2±0.2%FS (Economy type)
A3±0.05%FS (high Accuracy, order)
Explosion protection marking
CodeExplosion protection marking
E1[Ex ia] II C (Standard)
E2[Ex ia] II B
E3[Ex ib] II C (1 area)
Power supply
CodePower supply
P1Independent 24VDC electricity supply
P2DIN rail bus power supply (power distribution module)
P3Redundant 24VDC double power supply
Configuration interface
CodeConfiguration interface
S1USB Configuration (Standard)
S2RS485/Modbus Configuration
S3HART Configuration (programmable)
Additional functions
CodeAdditional functions
F1Basic Type
F2Open-circuit alarm output (up/down Optional)
F3F2 + channel failure relay contact point

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
VISCON-ISO-100 Programmable RTD / TC Input Isolator (Ex ia)