Programable thermal resistance (thermal voltage) into the separation fenceClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-ISO-100
Programable thermal resistance (thermal voltage) into the separation fence
Programable thermal resistance (thermal doll) enters a separation fence, and programmed thermal resistance/thermal doll enters a separation fence
01
Classification: Programable thermal resistance (thermal voltage) input barrier
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-ISO-100 |
|---|---|
| Product function | - Yes, sir. hazardous area (0 Region/ 1 Region) RTD or thermocouple Signal Passes intrinsic safety isolation After, in safe area Output standard 4–20mA (or) 1–5V The signal. DCS, PLC, Display instrument collection;input Sensor type and Range It can be programmed through software without the need to replace hardware |
| Explosion protection type | Intrinsic safety Type-associated equipment [T] Ex ia] II C;connectable 0 Region, 1 Region, 2 Sector II A/II B/II C in the explosive gas environment Intrinsically safe type Temperature sensors |
| Channel configuration | Standard one input, one output (1 channel); optional two inputs, two outputs 2 channel is isolated and separated between routes |
| Input signal | RTD: Pt100, Pt1000, Pt10, Cu50, Cu100, Cu53, Ni1000 (Second-line/ three-wire / four-wire); thermocouple: K, E, J, T, N, S, R, B;other possible 0–400Ω Interception input and -10–100mV millivol input |
| Temperature range | RTD -200–+850℃; thermocouple -200–+1800℃ (Pressed) sensor type); range The minimum/ceiling can be programmed in any way. range Range ≥50℃ |
| Output signal | 4–20mA (standard, load ≤500Ω); optional 1–5V (load ≥250kΩ); output corresponds to input linearity |
| Programming | Specialized configuration software is set by USB/RS485 sensor type, range, open-circuit alarm in direction, output positive/reverse, damping time (0–60s); parameters are detached and saved |
| Cold junction compensation | Thermocouple Input Pt1000 cold junction compensation compensation accuracy ±0.5℃; external fixed cold end or shut-down compensation can be set |
| Conversion accuracy | ±0.1%FS (23±2℃); temperature drift ≤0.01%FS/℃; ambient temperature -20–+60℃ Full range ≤±0.3%FS |
| Open-circuit protection | Sensor break wire, short-circuit output by default spill (≥22mA) or spill (≤3.6mA) and can output Alarm contact point (Optional) |
| Isolation performance | Three-way isolation between input, output, and power. Isolation: 1500 V AC for 1 min. Insulation resistance: ≥100 MΩ at 500 V DC. Common-mode rejection: ≥120 dB. |
| Intrinsic safety parameters | Um=250VAC/DC; Uo=26.0V, Io=93mA, Po=0.60W; Co=0.09μF, Lo=2.4mH (II C); II B Environment Co=0.65μF, Lo=8.0mH |
| Power supply | DC 20–35V (Quota 24V), texture ≤5%; single channel power ≤1.2W, dual channel ≤2.0W; with reverse Overvoltage protection |
| Response time | ≤300ms (with filters); damping time programmable 0–60s |
| Mounting | 35mm standard DIN rail cards in dense order; single channel thickness 12.5mm, two channels 18mm |
| Wiring | Plugged screws (2.5mm2); Hazardous area set with Safe area end subside and distinguished by blue markings |
| Operating environment | Temperature -20–+60℃, relative humidity ≤95%RH (Non-condensing); suitable for installation in control cabinets |
| Overall dimensions | Single channel 12.5 × 110 × 118mm; double channel 18 × 110 × 118mm (wide × high × deep) |
| Instrument weight | About 0.12kg (single channel) |
| Applicable standards | GB 3836.1 Explosive Environment 1 Part: Equipment General Requirements / GB 3836.4 ... 4 Part: Equipment protected by intrinsic safety i / GB/T 17626 (EMC) / IEC 60751 / IEC 60584 |
| Certification requirements | Explosion protection certificate; intrinsically safe system GB 3836.15 Intrinsic safety parameters after accounting |
| Typical applications | In installations with explosive gas environments such as oil, chemicals, gas, pharmaceuticals, on site RTD / thermocouple DCS PLC signalling separation and security isolation; especially suitable for Sensor type or Range on-site alteration and interoperability of spare parts |
| Product features | Sensor type programmable with Range software, one fence covering all Typical temperature sensors, single spare parts; three-end isolation, strong anti-terrestrial circulation and commo interference; Open-circuit failure direction programmable, interlock logic flexible; thin DIN rail installed, small occupancy of inner cabinet space |
Product selection
VISCON-ISO-100| Code | Number of channels |
|---|---|
| C1 | One input, one output (1 channel) |
| C2 | Two inputs, two outputs (2 channel, stand alone) |
| Code | Input type |
|---|---|
| T1 | RTD Input (Pt100/Cu50/Cu100) |
| T2 | RTD input (full score, including Pt1000/Ni1000/Cu53) |
| T3 | Thermocouple Input (K/E/J/T/N) |
| T4 | RTD + Thermocouple programmable (full functionality) |
| Code | Output signal |
|---|---|
| O1 | 4–20mA (Standard) |
| O2 | 1~5V |
| O3 | 4–20mA + Alarm Touch Output |
| Code | Accuracy class |
|---|---|
| A1 | ±0.1%FS (Standard) |
| A2 | ±0.2%FS (Economy type) |
| A3 | ±0.05%FS (high Accuracy, order) |
| Code | Explosion protection marking |
|---|---|
| E1 | [Ex ia] II C (Standard) |
| E2 | [Ex ia] II B |
| E3 | [Ex ib] II C (1 area) |
| Code | Power supply |
|---|---|
| P1 | Independent 24VDC electricity supply |
| P2 | DIN rail bus power supply (power distribution module) |
| P3 | Redundant 24VDC double power supply |
| Code | Configuration interface |
|---|---|
| S1 | USB Configuration (Standard) |
| S2 | RS485/Modbus Configuration |
| S3 | HART Configuration (programmable) |
| Code | Additional functions |
|---|---|
| F1 | Basic Type |
| F2 | Open-circuit alarm output (up/down Optional) |
| F3 | F2 + channel failure relay contact point |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us