4-20mA output operating end barrierClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-ISO-150
4-20mA output operating end barrier
4-20mA output operating end barrier, 4-20mA output operational end barrier
01
Classification: 4-20mA output operating end barrier
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-ISO-150 |
|---|---|
| Product function | Transfers the 4–20 mA control signal from the safe area (control room) to the hazardous area through intrinsic safety isolation. The intrinsically safe output circuit drives electro-pneumatic converters, valve positioners, variable frequency drives, and other actuators. |
| Explosion protection type | Associated apparatus marked [Ex ia] II C. The output can connect to intrinsically safe actuators in Zones 0, 1, and 2 for gas groups II A, II B, and II C. |
| Channel configuration | One input and one output as standard (1 channel). Optional two input/two output (2 independently isolated channels) or one input/two output (one signal drives two actuators). |
| Input signal | 4–20 mA in the safe area with input impedance ≤100 Ω. Options: 0–20 mA or 0–10 V (via 250 Ω sensing resistor). |
| Output signal | Intrinsically safe 4–20 mA output with 0–750 Ω load capacity. Output follows input with linearity error ≤0.1% FS. |
| Output protection | Output open-circuit and short-circuit protection with current limited to ≤28 mA, reverse polarity protection, and optional surge suppression. |
| HART pass-through | Bidirectional transparent HART pass-through with channel impedance ≥230 Ω. Configure and diagnose smart valve positioners in the hazardous area from the safe area without a bypass. |
| Conversion accuracy | ±0.1%FS (23±2℃); temperature drift ≤0.015%FS/℃; all-temperature ≤±0.3%FS |
| Response time | ≤20 ms for a 10%–90% step change, for fast control-loop response |
| Isolation performance | Three-way isolation between input, output, and power. Isolation: 1500 V AC for 1 min. Insulation resistance: ≥100 MΩ at 500 V DC. Common-mode rejection: ≥120 dB. |
| Intrinsic safety parameters | Um=250VAC/DC;Uo=28.0V,Io=93mA,Po=0.65W;Co=0.083μF,Lo=2.4mH(II C) |
| Power supply | 20–35 V DC (24 V nominal). Single-channel power ≤1.5 W (≤2.2 W at full load of 20 mA / 750 Ω). Reverse polarity and overvoltage protection. |
| Output indicator | Panel LED indicates the size of the output current (three colours: low/normal/high) to allow on-site assessment of circuit status (Optional) |
| Mounting | Snap-on mounting to a standard 35 mm DIN rail. Width: 12.5 mm for one channel or 18 mm for two channels. |
| Wiring | Pluggable screw terminals (2.5 mm²). Blue hazardous-area terminals are on the opposite side from the safe-area terminals. |
| Operating environment | Temperature -20–+60℃, relative humidity ≤95%RH (Non-condensing) |
| Overall dimensions | Single channel 12.5 × 110 × 118mm; double channel 18 × 110 × 118mm |
| Instrument weight | About 0.12kg (single channel) |
| Applicable standards | GB 3836.1 / GB 3836.4 / GB 3836.15 (intrinsically safe system)/ GB/T 17626 (EMC)/ IEC 61000-6-2 |
| Certification requirements | Explosion protection certificate from a national inspection body. Before use, verify the intrinsically safe circuit parameters, including cable inductance and capacitance, under GB 3836.15. |
| Typical applications | In chemical, petrochemical, gas storage, etc. control valve Electrical converter, variable frequency drive # The voice light # alarm (a) Control circuits; DCS/PLC and Hazardous area Actuator We're gonna need a signal quarantine and a security quarantine. |
| Product features | HART Transparent transmission, smart valve positioner can open the floor by safe area configuration; output drive high capacity (750Ω), long-range cables and low resistance loads are reliable; short-circuit limit flow protection prevents intrinsically safe circuit from accidentally ignited; thin DIN rail installed with ISO-100/200 |
Product selection
VISCON-ISO-150| Code | Number of channels |
|---|---|
| C1 | One input, one output (1 channel) |
| C2 | Two inputs, two outputs (2 channel, stand alone) |
| C3 | One input, two outputs (1 signal drive 2 Actuator) |
| Code | Input signal |
|---|---|
| I1 | 4–20mA (Standard) |
| I2 | 0~20mA |
| I3 | 0–10V (sampled electrical resistance) |
| Code | Output drive |
|---|---|
| O1 | 4~20mA / 0~500Ω |
| O2 | 4–20mA / 0–750Ω (Standard) |
| O3 | 4–20mA / 0–1000Ω (enhanced) |
| Code | HART functionality |
|---|---|
| H1 | HART |
| H2 | HART transparent transmission (Standard) |
| H3 | H2 + HART signal quarantine amplified. |
| Code | Accuracy class |
|---|---|
| A1 | ±0.1%FS (Standard) |
| A2 | ±0.2%FS (Economy type) |
| A3 | ±0.05%FS (high Accuracy, order) |
| Code | Explosion protection marking |
|---|---|
| E1 | [Ex ia] II C (Standard) |
| E2 | [Ex ia] II B |
| E3 | [Ex ib] II C |
| Code | Additional functions |
|---|---|
| F1 | Basic Type |
| F2 | Output current LED indication |
| F3 | F2 + outbound/shortway Alarm tangles |
| Code | Power supply |
|---|---|
| P1 | Independent 24VDC electricity supply |
| P2 | DIN rail bus power supply (power distribution module) |
| P3 | Redundant 24VDC double power supply |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.