VISCON-ISO-200

Transmitters, current input detection end barriers

Transmitters, current input detection end barriers, transmitter current detection end barriers

01

Classification: Transmissor, current input detection end separation fence

02

Check configuration based on field work

⁇ Return to the transmitter, current input detection end separation fence

TECHNICAL SPECIFICATIONS

Technical specifications

VISCON-ISO-200

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelVISCON-ISO-200
Product functionYes. hazardous area Second-line/ three-wire transmitter Provision intrinsically safe The power supply, and at the same time... transmitter Output 4–20mA Isolation, conversion. safe area standard Signals, for DCS, PLC, recorder collection; also used as a pure current input fence (without distribution)
Explosion protection typeIntrinsic safety associated equipment [Ex ia] II C; accessible 0, 1, 2 II A/II B/II C explosive gas environment Intrinsically safe type Transmitter
Channel configurationStandard one input, one output (1 channel); optional two inputs, two outputs 2 channel is isolated and distributed separately
Input signal4–20mA (2-wire transmitter with electricity); 4–20mA (three-wire / four-wire transmitter without electricity); 0– 20mA / 4–20mA pure current input; input impedance ≤50Ω without electricity distribution)
Transmitter excitationIntrinsically safe distribution voltage DC 18V (aerial) distribution current limit ≤25mA; short-circuit limit protection allowing long-term short-circuits to remain intact
Output signal4–20mA (load ≤500Ω, standard); optional 1–5V (load ≥250kΩ), 0–10V; output Optional positive/verse effect
HART pass-throughSupport HART for two-way transparent transmission, with Safe area Hazardous area Transmitter Configuration, Range adjustments and diagnostics without the need to cover the site
Conversion accuracy±0.1%FS (23±2℃); temperature drift ≤0.015%FS/℃; all-temperature -20–+60℃ ≤±0.3%FS
Response time≤50ms (10%–90% Step change)
Open-circuit protectionEnter the output by default for spilling (≥22mA) or spilling (≤3.6mA); output Alarm contact (Optional)
Isolation performanceThree-way isolation between input, output, and power. Isolation: 1500 V AC for 1 min. Insulation resistance: ≥100 MΩ at 500 V DC. Common-mode rejection: ≥120 dB.
Intrinsic safety parametersUm=250VAC/DC; Uo=26.0V, Io=93mA, Po=0.60W; Co=0.09μF, Lo=2.4mH (II C); II B Environment Co=0.65μF, Lo=8.0mH
Power supplyDC 20–35V (valid 24V); single channel ≤1.8W (allocation full load), dual channel ≤3.2W; reverse Overvoltage protection
MountingSnap-on mounting to a standard 35 mm DIN rail. Width: 12.5 mm for one channel or 18 mm for two channels.
WiringPlugged screws (2.5mm2); Hazardous area ender blue mark and set side by side with other circuits
Operating environmentTemperature -20–+60℃, relative humidity ≤95%RH (Non-condensing)
Overall dimensionsSingle channel 12.5 × 110 × 118mm; double channel 18 × 110 × 118mm
Instrument weightAbout 0.12kg (single channel)
Applicable standardsGB 3836.1 / GB 3836.4 / GB 3836.15 (intrinsically safe system)/ GB/T 17626 (EMC)/ IEC 61000-6-2
Certification requirementsExplosion protection certificate; intrinsically safe circuit to account for cable parameters based on GB 3836.15
Typical applicationsPressures in installations such as oil, chemical, gas, coal, differential pressure, level, temperature integration transmitter and DCS/PLC; replacement of the traditional Zina security fence without the need for a dedicated main line
Product featuresTest end-band distribution, one fence completes the power and signal separation; HART transparent transmission, smart transmitter configuration is exempt from the scene; short-circuit traffic protection is protected, the on-site connection is not damaged; no dedicated area (separated structure) is required, and the inside cabinet is simple; and the line is mixed with ISO-100/150

Product selection

VISCON-ISO-200
Number of channels
CodeNumber of channels
C1One input, one output (1 channel)
C2Two inputs, two outputs (2 channel, stand alone)
Input Method
CodeInput Method
I1Second-line Transmitter (with electricity)
I2Three-wire / Four-wire Transmitter (without electricity)
I3Pure current input 4–20mA (without electricity distribution)
I4/ Without electricity toggle
Output signal
CodeOutput signal
O14–20mA (Standard)
O21~5V
O30~10V
O44–20mA + Alarm Touch
HART functionality
CodeHART functionality
H1HART
H2HART transparent transmission (Standard)
H3H2 + HART quarantine zoom in
Accuracy class
CodeAccuracy class
A1±0.1%FS (Standard)
A2±0.2%FS (Economy type)
A3±0.05%FS (high Accuracy, order)
Explosion protection marking
CodeExplosion protection marking
E1[Ex ia] II C (Standard)
E2[Ex ia] II B
E3[Ex ib] II C
Open-circuit alarm
CodeOpen-circuit alarm
F1Spill (≥22mA)
F2Spills (≤3.6mA)
F3Keep final value
F4Up/down programmable
Power supply
CodePower supply
P1Independent 24VDC electricity supply
P2DIN rail bus power supply (power distribution module)
P3Redundant 24VDC double power supply

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
VISCON-ISO-200 Transmitter / Current Input Isolator (Ex ia)