Switch input, relay output barrier SA6110Click on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-ISO-350
Switch input, relay output barrier SA6110
Switch input, relay output separation fence SA6110, select the appropriate measurement and installation configuration in conjunction with the field condition.
01
Classification: Switch input, relay output fence SA6110
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-ISO-350 (corresponding model SA6110) |
|---|---|
| Product function | Collection Hazardous area Voltage-free contact or Wet contact Switch signal, pass. Intrinsic safety isolation Later. Safe area Converts the contact output by relay to state Display, Alarms and interlocks A simple structure, a large multi-capacity contact, suitable for a direct driver load |
| Explosion protection type | Intrinsic safety Type-associated equipment [T] Ex ia] II C;inputendable 0 Region, 1 Region, 2 Sector II A/II B/II C Switching sensors in explosive gas-type environments |
| Channel configuration | One input, one output (1 Channel: 1 Road Switch Input + 1 Group relay conversion point output (%2) 1 normally open + 1 Normally closed) |
| Input type | Voltage-free dry contact (mechanical contact, magnetic reed switch), wet contact (DC 24V, input current ≤8mA); input query voltage 8.2V, query current ≤6mA |
| Input characteristics | Introduction: circuit current ≥2.0mA; disconnection: circuit current ≤1.0mA; tape 20ms hardware to resist tremors and jamming actions |
| Output Type | Relay conversion touchpoint (PACT) SPDT), 1 normally open + 1 normally closed; contact rating 250VAC / 5A, 30VDC / 5A Directly driven intermediate relays, contact wire, acoustic light Alarm Devices |
| Output Logic | Normally open / normally closed optional (through endage or internal jump); optional output delay 0–10s (order) |
| Isolation performance | Input-output-power-triple-end isolation; isolation voltage 1500VAC/1min; insulation resistance ≥100MΩ (500VDC) |
| Intrinsic safety parameters | Um=250VAC/DC; Uo=10.6V, Io=15mA, Po=40mW; Co=2.4μF, Lo=165mH (II C); II B Environment Co=10μF, Lo=1H |
| Response time | ≤15ms (Input to relay action) |
| Mechanical lifetime | Relay electrical lifetime ≥100000 (calendar load) and mechanical lifetime ≥10000000 |
| Power supply | DC 20–35V (Quota 24V); ≤1.0W; has inverted Overvoltage protection |
| Output indicator | Panel LED: Power indicator (green), Input status indicator (yellow), relay action indicator (red) |
| Mounting | 35mm standard DIN rail carcass; thickness 12.5mm |
| Wiring | Plugged screws (2.5mm2); Hazardous area ender blue identification |
| Operating environment | Temperature -20–+60℃, relative humidity ≤95%RH (Non-condensing) |
| Overall dimensions | 12.5 × 110 × 118mm (wide × high × deep) |
| Instrument weight | 0.12kg |
| Applicable standards | GB 3836.1 / GB 3836.4 / GB 3836.15 (intrinsically safe system)/ GB/T 17626 (EMC) |
| Certification requirements | Explosion protection certificate; intrinsically safe circuit has to account for cable parameters GB 3836.15 |
| Typical applications | Level switch, field button, Alarm touchpoint status collection and isolation; replace traditional intermediate relay program by combining Intrinsic safety isolation with the point output |
| Product features | 5A large-capacity contact point, with direct loads, free of intermediate relays and extra inner space; single-channel thin 12.5mm with high internal density; 8.2V/6mA low energy query, Intrinsically safe wide side security sufficiency; three light signals, clear state of the scene; simple structure, low failure rate and low maintenance cost |
Product selection
VISCON-ISO-350| Code | Number of channels |
|---|---|
| C1 | One input, one output (Standard) |
| C2 | Two inputs, two outputs (order) |
| Code | Input type |
|---|---|
| I1 | Voltage-free dry contact |
| I2 | Wet contact DC 24V |
| I3 | Dry contact / Wet contact compatibility |
| Code | Output contacts |
|---|---|
| O1 | 1 normally open + 1 normally closed (SPDT, Standard) |
| O2 | 2 normally open (NO) |
| O3 | 2 normally closed (NC) |
| Code | Contact rating |
|---|---|
| K1 | 250VAC/5A, 30VDC/5A (Standard) |
| K2 | 250VAC/2A (sign level) |
| K3 | 250VAC/10A (Increased capacity, orders) |
| Code | Switching logic |
|---|---|
| F1 | Active (input closed relay insulation) |
| F2 | Inverse (input closed relay release) |
| F3 | Time delay with output 0–10s (order) |
| Code | Explosion protection marking |
|---|---|
| E1 | [Ex ia] II C (Standard) |
| E2 | [Ex ia] II B |
| E3 | [Ex ib] II C |
| Code | Indicator configuration |
|---|---|
| L1 | Power + action double lights |
| L2 | Power + Input + action 3 lights (Standard) |
| Code | Power supply |
|---|---|
| P1 | Independent 24VDC electricity supply |
| P2 | DIN rail bus power supply (power distribution module) |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us