Switch input, relay output barrier SA6110Click on the picture to zoom in.

PRODUCT SPECIFICATIONS

VISCON-ISO-350

Switch input, relay output barrier SA6110

Switch input, relay output separation fence SA6110, select the appropriate measurement and installation configuration in conjunction with the field condition.

01

Classification: Switch input, relay output fence SA6110

02

Check configuration based on field work

⁇ Return switch input, relay output barrier SA6110 class

TECHNICAL SPECIFICATIONS

Technical specifications

VISCON-ISO-350

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelVISCON-ISO-350 (corresponding model SA6110)
Product functionCollection Hazardous area Voltage-free contact or Wet contact Switch signal, pass. Intrinsic safety isolation Later. Safe area Converts the contact output by relay to state Display, Alarms and interlocks A simple structure, a large multi-capacity contact, suitable for a direct driver load
Explosion protection typeIntrinsic safety Type-associated equipment [T] Ex ia] II C;inputendable 0 Region, 1 Region, 2 Sector II A/II B/II C Switching sensors in explosive gas-type environments
Channel configurationOne input, one output (1 Channel: 1 Road Switch Input + 1 Group relay conversion point output (%2) 1 normally open + 1 Normally closed)
Input typeVoltage-free dry contact (mechanical contact, magnetic reed switch), wet contact (DC 24V, input current ≤8mA); input query voltage 8.2V, query current ≤6mA
Input characteristicsIntroduction: circuit current ≥2.0mA; disconnection: circuit current ≤1.0mA; tape 20ms hardware to resist tremors and jamming actions
Output TypeRelay conversion touchpoint (PACT) SPDT), 1 normally open + 1 normally closed; contact rating 250VAC / 5A, 30VDC / 5A Directly driven intermediate relays, contact wire, acoustic light Alarm Devices
Output LogicNormally open / normally closed optional (through endage or internal jump); optional output delay 0–10s (order)
Isolation performanceInput-output-power-triple-end isolation; isolation voltage 1500VAC/1min; insulation resistance ≥100MΩ (500VDC)
Intrinsic safety parametersUm=250VAC/DC; Uo=10.6V, Io=15mA, Po=40mW; Co=2.4μF, Lo=165mH (II C); II B Environment Co=10μF, Lo=1H
Response time≤15ms (Input to relay action)
Mechanical lifetimeRelay electrical lifetime ≥100000 (calendar load) and mechanical lifetime ≥10000000
Power supplyDC 20–35V (Quota 24V); ≤1.0W; has inverted Overvoltage protection
Output indicatorPanel LED: Power indicator (green), Input status indicator (yellow), relay action indicator (red)
Mounting35mm standard DIN rail carcass; thickness 12.5mm
WiringPlugged screws (2.5mm2); Hazardous area ender blue identification
Operating environmentTemperature -20–+60℃, relative humidity ≤95%RH (Non-condensing)
Overall dimensions12.5 × 110 × 118mm (wide × high × deep)
Instrument weight0.12kg
Applicable standardsGB 3836.1 / GB 3836.4 / GB 3836.15 (intrinsically safe system)/ GB/T 17626 (EMC)
Certification requirementsExplosion protection certificate; intrinsically safe circuit has to account for cable parameters GB 3836.15
Typical applicationsLevel switch, field button, Alarm touchpoint status collection and isolation; replace traditional intermediate relay program by combining Intrinsic safety isolation with the point output
Product features5A large-capacity contact point, with direct loads, free of intermediate relays and extra inner space; single-channel thin 12.5mm with high internal density; 8.2V/6mA low energy query, Intrinsically safe wide side security sufficiency; three light signals, clear state of the scene; simple structure, low failure rate and low maintenance cost

Product selection

VISCON-ISO-350
Number of channels
CodeNumber of channels
C1One input, one output (Standard)
C2Two inputs, two outputs (order)
Input type
CodeInput type
I1Voltage-free dry contact
I2Wet contact DC 24V
I3Dry contact / Wet contact compatibility
Output contacts
CodeOutput contacts
O11 normally open + 1 normally closed (SPDT, Standard)
O22 normally open (NO)
O32 normally closed (NC)
Contact rating
CodeContact rating
K1250VAC/5A, 30VDC/5A (Standard)
K2250VAC/2A (sign level)
K3250VAC/10A (Increased capacity, orders)
Switching logic
CodeSwitching logic
F1Active (input closed relay insulation)
F2Inverse (input closed relay release)
F3Time delay with output 0–10s (order)
Explosion protection marking
CodeExplosion protection marking
E1[Ex ia] II C (Standard)
E2[Ex ia] II B
E3[Ex ib] II C
Indicator configuration
CodeIndicator configuration
L1Power + action double lights
L2Power + Input + action 3 lights (Standard)
Power supply
CodePower supply
P1Independent 24VDC electricity supply
P2DIN rail bus power supply (power distribution module)

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
VISCON-ISO-350 Digital Input Isolator with Relay Output (SA6110)