Smart SeparatorClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

VISCON-ISO-400

Smart Separator

Smart separators, smart signal separators.

01

Classification: Smart Separator

02

Check configuration based on field work

⁇ Return Smart Separator Classification

TECHNICAL SPECIFICATIONS

Technical specifications

VISCON-ISO-400

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelVISCON-ISO-400
Product functionUniversal signal quarantine Converter: all-round input of a quarantined, linearized, calculated and exported signal Standard, which is used to eliminate circulation, inhibit interference, match different signal formulas and achieve Range conversion distribution of signals
Input typeAltruistic input (programmable): 4–20mA, 0–20mA, 0–10V, 0–5V, 1–5V, -10– 100mV, 0–400Ω, 0–4kΩ Frequency 0–10kHz and RTD Pt100/Pt1000/Cu50/Cu100, thermocouple K/E/J/T/N/S/R/B
Input impedance≤50Ω (can and 250Ω sampling); voltage ≥1MΩ; thermocouple input ≥10MΩ; overpressure protection
Output TypeStandard 4–20mA (load ≤750Ω) may be switched to 1–5V (load ≥250kΩ); the second route may be set as 4–20mA, 1–5V or relay contact point (Alarm)
Range conversionInput range & With Output range All programmable settings can support any segment linear compression/extension; and start-up operations (differential pressure The flow low-flow cutoff (0–20%)
Conversion accuracy±0.1%FS (23±2℃); temperature drift ≤0.015%FS/℃; all-temperature -20–+60℃ ≤±0.3%FS
Isolation performanceInput - Output 1 — Output 2 — power source 4x4; isolation voltage 1500VAC/1min; insulation resistance ≥100MΩ (500VDC); common-mode rejection ≥120dB, serial inhibition ≥60dB
Response and filteringResponse time ≤100ms; digital filter 0–30s is available (0.1s step); can inhibit Display beat caused by high frequency interference on site
Function AlarmFour configurable alarm points (high-high, high, low, and low-low) with adjustable hysteresis. Output via relay contacts (250 VAC / 1 A) or open collector.
Open-circuit protectionEnter breakline or over range, the output is spilled as set (≥22mA)/ Downspill () ≤3.6mA) / Keep the final value; Thermocouple Breaking wires can identify and point upwards.
Configuration methodPC Software implementation USB or RS485 configuration;pane buttons + 3 bits LED/LCD Display (Display model; parametric power loss saving; copying of supporting parametrics to the same Model Batch Download
DisplayOptional 3.5 bit LED digital display or 2.4 in LCD dotted Display, Display input, output Alarm status
Power supplyDC 20–35V (value 24V) or AC 85–265V broad pressure; power ≤2.0W
Mounting35mm standard DIN rail Cassettes; thickness 18mm (one input, two outputs), 12.5mm (One input, one output)
WiringPlugged screws (2.5mm2), input/output/power/ Alarm partition layout
Operating environmentTemperature -20–+60℃, relative humidity ≤95%RH (Non-condensing)
Overall dimensions18 × 110 × 118mm (One input, two outputs)
Instrument weight0.15kg
Applicable standardsGB/T 17626 (EMC) / IEC 61000-6-2 / GB/T 18271 (process measurement and control device performance assessment) / IEC 60751 / IEC 60584
Typical applicationsDCS/PLC system signal interface Standard, signal-forming conversion in the adaptation of old and new systems, segregation of severe circuits in-situ interference, simultaneous supply of the same point to the control system in-situ Display / recorder; also available for integrated access to special signals such as temperature, frequency, etc.
Product featuresAll-round input programmable, with one separators replacing more than a dozen fixed Model, spare parts and selections are extremely simple; four-end isolation, anti-terrestrial circulation and commo disrupting capacity is high; open side, Low-flow cutoff and Range are supported randomly, without the need to replace hardware on site; four points Alarm and breakline recognition, circuit anomalies can be actively reported; parameters can be copied down in bulk and debug efficiency is high

Product selection

VISCON-ISO-400
Channel configuration
CodeChannel configuration
C1One input, one output
C2One input, two outputs (Standard)
C3Two inputs, two outputs
Input type
CodeInput type
I1Electricity 4–20mA / 0–20mA
I2Electricity 0–10V / 1–5V / mV
I3RTD / Thermocouple (temperature input)
I4Frequency / pulse 0–10kHz
I5Almighty input (all above, Standard)
Output Type
CodeOutput Type
O14–20mA
O2Two roads 4–20mA (Standard)
O34–20mA + 1–5V
O44–20mA + Alarm Touchpoint
Accuracy class
CodeAccuracy class
A1±0.1%FS (Standard)
A2±0.2%FS (Economy type)
A3±0.05%FS (high Accuracy, order)
Calculation functions
CodeCalculation functions
F1Linear transformation
F2F1 + open source calculation (flow)
F3F2 + low-flow cutoff (0–20%)
F4F3 + 4 Alarm and Hysteresis set
Display and configuration
CodeDisplay and configuration
D1no display, PC Configuration
D23.5 bit LED display + Key Configuration
D32.4 in LCD display + USB/RS485 Configuration
Power supply
CodePower supply
P1DC 24V(20~35V)
P2AC 85–265V broad pressure
P3DC 24V redundant double-track input
Special Configuration
CodeSpecial Configuration
S1General type (Non-Ex)
S2Intrinsically safe Association Type [Ex ia] II C (order)
S3Transparent transfer with HART (order)

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
VISCON-ISO-400 Smart Universal Signal Isolator