PRODUCT SPECIFICATIONS
VISCON-ISO-400
Smart Separator
Smart separators, smart signal separators.
01
Classification: Smart Separator
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-ISO-400 |
|---|---|
| Product function | Universal signal quarantine Converter: all-round input of a quarantined, linearized, calculated and exported signal Standard, which is used to eliminate circulation, inhibit interference, match different signal formulas and achieve Range conversion distribution of signals |
| Input type | Altruistic input (programmable): 4–20mA, 0–20mA, 0–10V, 0–5V, 1–5V, -10– 100mV, 0–400Ω, 0–4kΩ Frequency 0–10kHz and RTD Pt100/Pt1000/Cu50/Cu100, thermocouple K/E/J/T/N/S/R/B |
| Input impedance | ≤50Ω (can and 250Ω sampling); voltage ≥1MΩ; thermocouple input ≥10MΩ; overpressure protection |
| Output Type | Standard 4–20mA (load ≤750Ω) may be switched to 1–5V (load ≥250kΩ); the second route may be set as 4–20mA, 1–5V or relay contact point (Alarm) |
| Range conversion | Input range & With Output range All programmable settings can support any segment linear compression/extension; and start-up operations (differential pressure The flow low-flow cutoff (0–20%) |
| Conversion accuracy | ±0.1%FS (23±2℃); temperature drift ≤0.015%FS/℃; all-temperature -20–+60℃ ≤±0.3%FS |
| Isolation performance | Input - Output 1 — Output 2 — power source 4x4; isolation voltage 1500VAC/1min; insulation resistance ≥100MΩ (500VDC); common-mode rejection ≥120dB, serial inhibition ≥60dB |
| Response and filtering | Response time ≤100ms; digital filter 0–30s is available (0.1s step); can inhibit Display beat caused by high frequency interference on site |
| Function Alarm | Four configurable alarm points (high-high, high, low, and low-low) with adjustable hysteresis. Output via relay contacts (250 VAC / 1 A) or open collector. |
| Open-circuit protection | Enter breakline or over range, the output is spilled as set (≥22mA)/ Downspill () ≤3.6mA) / Keep the final value; Thermocouple Breaking wires can identify and point upwards. |
| Configuration method | PC Software implementation USB or RS485 configuration;pane buttons + 3 bits LED/LCD Display (Display model; parametric power loss saving; copying of supporting parametrics to the same Model Batch Download |
| Display | Optional 3.5 bit LED digital display or 2.4 in LCD dotted Display, Display input, output Alarm status |
| Power supply | DC 20–35V (value 24V) or AC 85–265V broad pressure; power ≤2.0W |
| Mounting | 35mm standard DIN rail Cassettes; thickness 18mm (one input, two outputs), 12.5mm (One input, one output) |
| Wiring | Plugged screws (2.5mm2), input/output/power/ Alarm partition layout |
| Operating environment | Temperature -20–+60℃, relative humidity ≤95%RH (Non-condensing) |
| Overall dimensions | 18 × 110 × 118mm (One input, two outputs) |
| Instrument weight | 0.15kg |
| Applicable standards | GB/T 17626 (EMC) / IEC 61000-6-2 / GB/T 18271 (process measurement and control device performance assessment) / IEC 60751 / IEC 60584 |
| Typical applications | DCS/PLC system signal interface Standard, signal-forming conversion in the adaptation of old and new systems, segregation of severe circuits in-situ interference, simultaneous supply of the same point to the control system in-situ Display / recorder; also available for integrated access to special signals such as temperature, frequency, etc. |
| Product features | All-round input programmable, with one separators replacing more than a dozen fixed Model, spare parts and selections are extremely simple; four-end isolation, anti-terrestrial circulation and commo disrupting capacity is high; open side, Low-flow cutoff and Range are supported randomly, without the need to replace hardware on site; four points Alarm and breakline recognition, circuit anomalies can be actively reported; parameters can be copied down in bulk and debug efficiency is high |
Product selection
VISCON-ISO-400| Code | Channel configuration |
|---|---|
| C1 | One input, one output |
| C2 | One input, two outputs (Standard) |
| C3 | Two inputs, two outputs |
| Code | Input type |
|---|---|
| I1 | Electricity 4–20mA / 0–20mA |
| I2 | Electricity 0–10V / 1–5V / mV |
| I3 | RTD / Thermocouple (temperature input) |
| I4 | Frequency / pulse 0–10kHz |
| I5 | Almighty input (all above, Standard) |
| Code | Output Type |
|---|---|
| O1 | 4–20mA |
| O2 | Two roads 4–20mA (Standard) |
| O3 | 4–20mA + 1–5V |
| O4 | 4–20mA + Alarm Touchpoint |
| Code | Accuracy class |
|---|---|
| A1 | ±0.1%FS (Standard) |
| A2 | ±0.2%FS (Economy type) |
| A3 | ±0.05%FS (high Accuracy, order) |
| Code | Calculation functions |
|---|---|
| F1 | Linear transformation |
| F2 | F1 + open source calculation (flow) |
| F3 | F2 + low-flow cutoff (0–20%) |
| F4 | F3 + 4 Alarm and Hysteresis set |
| Code | Display and configuration |
|---|---|
| D1 | no display, PC Configuration |
| D2 | 3.5 bit LED display + Key Configuration |
| D3 | 2.4 in LCD display + USB/RS485 Configuration |
| Code | Power supply |
|---|---|
| P1 | DC 24V(20~35V) |
| P2 | AC 85–265V broad pressure |
| P3 | DC 24V redundant double-track input |
| Code | Special Configuration |
|---|---|
| S1 | General type (Non-Ex) |
| S2 | Intrinsically safe Association Type [Ex ia] II C (order) |
| S3 | Transparent transfer with HART (order) |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us