Smart Double-Colour Dynamite LilometerClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-LEV-100
Smart Double-Colour Dynamite Lilometer
Smart Double-Colour Dynamite Lilometer, Smart Two-Colour Dynamite Lilometer
01
Classification: Smart double-coloured point liquid bits
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-LEV-100 |
|---|---|
| Product function | Measuring chamber electrodes are distributed at an altitude equal to a set electrical contact, which is judged by point using the huge difference between water and vapour (or air) conductivity, and is water-free at the point with double colour LED light column Display water level; in-situ view and long-range signal is prepared for continuous monitoring of the water levels, such as boiler packs, deoxifiers, condensers hot wells, etc. |
| Measurement principle | Water (conductive rate ≥5μS/cm) creates dozens of kΩ Quantities between the electrodes and the cylinders, which are considered to be water-free; when in steam or air, resistance is prevented to rise to MΩ, which is considered water-free. Compared with point-to-point scanning, full-scope scanning cycle 100ms, not affected by Process medium temperature, pressure, density change, and no compensation Differential pressure |
| Measurement range | 0–±300mm with normal water level; actual range determined by length and number of points of cartridge, spacing between sensing points 10 / 15 / 20 / 30mm 4 Optional |
| Number of electrode points | Standard 19 Dot. optional 21 / 24 points;each point is independent Electrical contact I'm going back to independence, and I'm going back to my own. Display It doesn't make the whole thing go wrong. |
| Electrode material | Ultra-purified aluminium ceramic insulation (standard), electrode core 1Cr18Ni9Ti; high pressure compartments employ ceramic and metal sealing structures that are resistant to temperature ≤450℃, pressure ≤22MPa; corrosive medium optional PTFE insulation electrode |
| Operating pressure | 2.5 / 6.4 / 10 / 16 / 22MPa 5 and selected by the rated pressure of the boiler or container; the wall thickness of the cartridge matches the grade Flange |
| Working temperature | Respond to saturation temperature under pressure, maximum 450℃ (22MPa class); actual wall temperature is to be accounted for under dissipation conditions when the outer wall of the cartridge is not warm |
| Display type | Double LED light column: below water level (water side) display green, above (gas side) display red colour area, i.e. actual water level; attached 4 bit display (mm or %) and 19/21/24 dot-state indicator |
| Display accuracy | ±1 point spacing (20mm spacing ±20mm); resolution equals point spacing and therefore the spacing becomes thinner than the small reading |
| Output signal | 1 road 4–20mA (linear range load ≤500Ω); 1 road RS485 (Modbus RTU from station) can upload water levels, points and Alarm |
| Alarms and interlocks | Water level high-high limit, ceiling, floor, low-low limit 4 alarm, relay 4 (250VAC/2A); can be set for tri-judgement with 3–10s delay to avoid false water levels caused by a mutation of loads and avoid accidental shutdown |
| Measuring chamber | 20# seamless steel pipe (≤10MPa) or 15CrMo / 12Cr1MoV (high pressure); inner diameter φ76 or φ89, on both sides Flange, on the side of the car and on the side of the water |
| Drain and sampling | Lower end of cartridge DN10 sewage valve interface, upper end exhaust interface; electrodes Simplex unassembled, replacement without empty cartridges, short time for overhaul |
| Ingress protection | Display meters IP65 (painted or walled); electrodes junction box IP65, optional flameproof type Ex d II C T4 |
| Power supply | AC 85–265V (50/60Hz It's a lot of work. ≤15VA; optional DC 24V |
| Mounting | Measuring chamber vertically installed; gas, water side-sampling tube level access, pipe inner diameter ≥20mm, length ≤600mm, slope ≥1:100 easy to re-enter water, avoiding piped gas causing false water levels |
| Instrument weight | Measuring chamber about 12kg (19 dot, φ76 600mm); display gauge 2.5kg |
| Applicable standards | JB/T 9248 (level count)/ DL/T 665 Reference (firing pipe design)/ GB/T 17626 (EMC)/ GB 4208 (shell Ingress protection) |
| Typical applications | Station boiler-packing level, industrial boiler-pack, deoxygen, condenser heater, high-pressure heater, water-level protection and triple-trigger locking system; also for water tanks requiring in situ visual readings and salt-free tanks |
| Product features | Two-colour light columns indicate the water level directly in the line of colour and can be seen on the edge of the platform; the point-by-point independent judgement Simplex electrodes fail by one cell and do not misread an entire water level; four o'clock Alarm with a delay of two times and three to avoid a false water level; electrodes can be replaced online Simplex with no need to stop the furnace to drain water |
Product selection
VISCON-LEV-100| Code | Number of electrode points |
|---|---|
| E19 | 19 dot (Standard) |
| E21 | 21 point |
| E24 | 24 point |
| Code | Nominal pressure |
|---|---|
| P25 | 2.5MPa |
| P64 | 6.4MPa |
| P100 | 10MPa (Standard) |
| P160 | 16MPa |
| P220 | 22MPa |
| Code | Spacing between sensing points |
|---|---|
| S10 | 10mm |
| S15 | 15mm |
| S20 | 20mm (Standard) |
| S30 | 30mm |
| Code | Electrode type |
|---|---|
| D1 | Ceramic insulation standard type (≤10MPa) |
| D2 | Ceramic metal seals high temperature, high pressure |
| D3 | Flameproof type Ex d II C T4 |
| D4 | PTFE Corrosion-resistant type |
| Code | Cylinder material |
|---|---|
| M1 | 20# seamless steel pipe |
| M2 | 15CrMo |
| M3 | 12Cr1MoV |
| M4 | 304 Stainless steel |
| Code | Display and output |
|---|---|
| O1 | + Number Display |
| O2 | Optical + number + 4–20mA |
| O3 | Optical column + number + 4–20mA + RS485 (Standard) |
| Code | Alarms and interlocks |
|---|---|
| A2 | 2 group Alarm |
| A4 | Group IV Alarm (High-high limit /ceiling/ceiling/ Low-low limit) |
| A5 | A4 + 33 + Delay |
| Code | Power supply and protection |
|---|---|
| V1 | AC 220V, instrument IP65 |
| V2 | DC 24V, instrument IP65 |
| V3 | AC 220V flameproof Ex d |