Smart Double-Colour Dynamite LilometerClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

VISCON-LEV-100

Smart Double-Colour Dynamite Lilometer

Smart Double-Colour Dynamite Lilometer, Smart Two-Colour Dynamite Lilometer

01

Classification: Smart double-coloured point liquid bits

02

Check configuration based on field work

⁇ Return Smart Double-Coloured Point Liquefied-Performance Classification

TECHNICAL SPECIFICATIONS

Technical specifications

VISCON-LEV-100

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelVISCON-LEV-100
Product functionMeasuring chamber electrodes are distributed at an altitude equal to a set electrical contact, which is judged by point using the huge difference between water and vapour (or air) conductivity, and is water-free at the point with double colour LED light column Display water level; in-situ view and long-range signal is prepared for continuous monitoring of the water levels, such as boiler packs, deoxifiers, condensers hot wells, etc.
Measurement principleWater (conductive rate ≥5μS/cm) creates dozens of kΩ Quantities between the electrodes and the cylinders, which are considered to be water-free; when in steam or air, resistance is prevented to rise to MΩ, which is considered water-free. Compared with point-to-point scanning, full-scope scanning cycle 100ms, not affected by Process medium temperature, pressure, density change, and no compensation Differential pressure
Measurement range0–±300mm with normal water level; actual range determined by length and number of points of cartridge, spacing between sensing points 10 / 15 / 20 / 30mm 4 Optional
Number of electrode pointsStandard 19 Dot. optional 21 / 24 points;each point is independent Electrical contact I'm going back to independence, and I'm going back to my own. Display It doesn't make the whole thing go wrong.
Electrode materialUltra-purified aluminium ceramic insulation (standard), electrode core 1Cr18Ni9Ti; high pressure compartments employ ceramic and metal sealing structures that are resistant to temperature ≤450℃, pressure ≤22MPa; corrosive medium optional PTFE insulation electrode
Operating pressure2.5 / 6.4 / 10 / 16 / 22MPa 5 and selected by the rated pressure of the boiler or container; the wall thickness of the cartridge matches the grade Flange
Working temperatureRespond to saturation temperature under pressure, maximum 450℃ (22MPa class); actual wall temperature is to be accounted for under dissipation conditions when the outer wall of the cartridge is not warm
Display typeDouble LED light column: below water level (water side) display green, above (gas side) display red colour area, i.e. actual water level; attached 4 bit display (mm or %) and 19/21/24 dot-state indicator
Display accuracy±1 point spacing (20mm spacing ±20mm); resolution equals point spacing and therefore the spacing becomes thinner than the small reading
Output signal1 road 4–20mA (linear range load ≤500Ω); 1 road RS485 (Modbus RTU from station) can upload water levels, points and Alarm
Alarms and interlocksWater level high-high limit, ceiling, floor, low-low limit 4 alarm, relay 4 (250VAC/2A); can be set for tri-judgement with 3–10s delay to avoid false water levels caused by a mutation of loads and avoid accidental shutdown
Measuring chamber20# seamless steel pipe (≤10MPa) or 15CrMo / 12Cr1MoV (high pressure); inner diameter φ76 or φ89, on both sides Flange, on the side of the car and on the side of the water
Drain and samplingLower end of cartridge DN10 sewage valve interface, upper end exhaust interface; electrodes Simplex unassembled, replacement without empty cartridges, short time for overhaul
Ingress protectionDisplay meters IP65 (painted or walled); electrodes junction box IP65, optional flameproof type Ex d II C T4
Power supplyAC 85–265V (50/60Hz It's a lot of work. ≤15VA; optional DC 24V
MountingMeasuring chamber vertically installed; gas, water side-sampling tube level access, pipe inner diameter ≥20mm, length ≤600mm, slope ≥1:100 easy to re-enter water, avoiding piped gas causing false water levels
Instrument weightMeasuring chamber about 12kg (19 dot, φ76 600mm); display gauge 2.5kg
Applicable standardsJB/T 9248 (level count)/ DL/T 665 Reference (firing pipe design)/ GB/T 17626 (EMC)/ GB 4208 (shell Ingress protection)
Typical applicationsStation boiler-packing level, industrial boiler-pack, deoxygen, condenser heater, high-pressure heater, water-level protection and triple-trigger locking system; also for water tanks requiring in situ visual readings and salt-free tanks
Product featuresTwo-colour light columns indicate the water level directly in the line of colour and can be seen on the edge of the platform; the point-by-point independent judgement Simplex electrodes fail by one cell and do not misread an entire water level; four o'clock Alarm with a delay of two times and three to avoid a false water level; electrodes can be replaced online Simplex with no need to stop the furnace to drain water

Product selection

VISCON-LEV-100
Number of electrode points
CodeNumber of electrode points
E1919 dot (Standard)
E2121 point
E2424 point
Nominal pressure
CodeNominal pressure
P252.5MPa
P646.4MPa
P10010MPa (Standard)
P16016MPa
P22022MPa
Spacing between sensing points
CodeSpacing between sensing points
S1010mm
S1515mm
S2020mm (Standard)
S3030mm
Electrode type
CodeElectrode type
D1Ceramic insulation standard type (≤10MPa)
D2Ceramic metal seals high temperature, high pressure
D3Flameproof type Ex d II C T4
D4PTFE Corrosion-resistant type
Cylinder material
CodeCylinder material
M120# seamless steel pipe
M215CrMo
M312Cr1MoV
M4304 Stainless steel
Display and output
CodeDisplay and output
O1+ Number Display
O2Optical + number + 4–20mA
O3Optical column + number + 4–20mA + RS485 (Standard)
Alarms and interlocks
CodeAlarms and interlocks
A22 group Alarm
A4Group IV Alarm (High-high limit /ceiling/ceiling/ Low-low limit)
A5A4 + 33 + Delay
Power supply and protection
CodePower supply and protection
V1AC 220V, instrument IP65
V2DC 24V, instrument IP65
V3AC 220V flameproof Ex d

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
VISCON-LEV-100 Intelligent Two-Colour Electrode Level Gauge