VISCON-OP-150
Smart Handheld
Smart handman, smart handman.
01
Classification: Smart hand-manufacturing
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-OP-150 |
|---|---|
| Product function | The string is linked between the regulator (or DCS output) and Actuator, with a manual/automatic two-way no-disturbing switch; the output follows strictly the upper signal during the automated state, and the output panel is assigned a value to be taken over on site in case of overhaul, debugging, failure of the upper system or abnormality of the process |
| Input signal | 1 auto-routing input: 4–20mA (load 250Ω) or 1–5V; input impedance 250Ω; acceptable Transmitter output from regulators, DCS analogue output cards or paperless recorders |
| Output signal | 1 road 4–20mA output (load ≤750Ω, constant stream output) or server on reverse relay output (AC 220V/1A); separation of output from input, power source |
| Tracking Mode | Automatic status is undisturbed tracking: output equals input in real time, deviation ≤0.1%FS; value maintained at the switch time by automatic hand-to-hand output does not produce step change; smoothing down input values at the set tilt (0.1 –100%/s) when hand-to-hand automatic |
| Manual setpoint | Panel up/down key up and down output, one step 0.1%, 1%, 10% Number three. optional; long at consecutive rates of increase or decrease 0.1–10%/s available;or directly type a value |
| Valve position limits | Output high and low limits 0–100% is set at random (e. g. 5%–95%) and post-limit output does not cross; limit value is password protected to prevent error |
| Display unit | Two rows 4 bit LED digital pipe: upper row display input value (PV), lower row display output value (MV); two blight poles indicating input and output, respectively; three state lamps Display manual, automatic, malfunctioning |
| Measurement accuracy | Enter conversion ±0.2%FS; output ±0.2%FS; output warm ≤0.01%FS/℃; A/D and D/A are 16 bits |
| Fault management | Enter a breakline (≤3.6mA or ≥21.0mA) that automatically cuts to manual and maintains the final effective output, while lighting down the failure light and driving Alarm contact point; the output circuit breaker is detectable and Alarm |
| State Output | Manual/automated state relay contact output (dry contact for DCS or locking system to read who currently controls it); additional malfunction contact 1 group |
| Function Alarm | Enter breaklines, output exceeding limit, output circuit breakers, limit bands crossing four categories alarm; relay capacity 250VAC/2A |
| Communication interface | RS485 (Modbus RTU from station); remote reading of input values, output values, hand status and remote execution of Manual / automatic changeover (opposable) |
| Power supply | AC 85–265V (50/60Hz), power ≤5VA; optional DC 24V; output circuits isolated from power 1500VAC |
| Enclosure and protection | Disk 96×96mm, front plate IP65, back end IP20; key belt Optional |
| Panel cutout dimensions | 92 × 92mm (wide × high), insertion depth ≤110mm |
| Instrument weight | 0.5kg |
| Applicable standards | JB/T 8214 (industrial process control regulator)/ GB/T 17626 (EMC)/ GB/T 34037 |
| Typical applications | The side operation of the key adjuster circuits (e.g., carbag water level, furnace temperature, reaction sheet temperature); DCS temporary take-over during overhaul of the output card; manual operating layer between the single circuit adjuster and the electric valve; replacement of the test vehicle phase with the regulator for the valve level |
| Product features | Tracking accuracy high, manual / automatic changeover undisturbed, process free of shock; auto-maintenance of final output instead of zero when entering offlines, avoiding the complete closure or full-opening of valves; handing dry contact to DCS, attribution of operational rights retroactive; limited band password protection to prevent on-site error to push valves to the limit |
Product selection
VISCON-OP-150| Code | Output Type |
|---|---|
| O1 | 4–20mA Handstream output (Standard) |
| O2 | Server positive and reverse relays (AC 220V/1A) |
| O3 | 4–20mA + Dual output |
| O4 | 0–10V voltage output |
| Code | Input signal |
|---|---|
| I1 | 4~20mA |
| I2 | 1~5V |
| I3 | 0~10V |
| I4 | 4–20mA + Valve feedback input (two channels) |
| Code | Display configuration |
|---|---|
| D1 | Double row 4 LED (PV + MV) |
| D2 | Two rows LED + Double-light column (Standard) |
| D3 | Double row LED + Double-light column + Output Display |
| Code | Switching method |
|---|---|
| C1 | Panel key Manual / automatic changeover (Standard) |
| C2 | Panel key + External Voltage-free contact Remote Switch |
| C3 | Panel key + Remote Switch + Top Switch (permissible) |
| Code | Output limits and rate |
|---|---|
| L1 | Output high and low limits available (0–100%) |
| L2 | L1 + manual increase rate (0.1–10%/s) |
| L3 | L2 + hand-cut smooth slope (0.1–100%/s) |
| Code | Alarms and status |
|---|---|
| P1 | Alarm contact 1 group |
| P2 | Fault contact + manual/automatic contact (Standard) |
| P3 | P2 + Enter breakup / output breakup / ultra-strict three types of independence Alarm |
| Code | Communication interface |
|---|---|
| T1 | Communication |
| T2 | RS485(Modbus RTU) |
| T3 | RS485 + Ethernet |
| Code | Power supply |
|---|---|
| V1 | AC 220V(85~265V) |
| V2 | DC 24V |
| V3 | Double power (AC + DC automatic switch) |