Smart server control PID regulatorClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-PID-100
Smart server control PID regulator
Smart server control PID regulator, smart server control PID regulator
01
Classification: Smart server control PID regulator
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-PID-100 |
|---|---|
| Product function | Receiving temperature, pressure, flow, level Wait for the signal to be measured. PID A three-state signal-driven electric server to output positive/reverse/cut after operation Actuator (Electro) Control valve, servers) to achieve closed loops; with valve feedback closed, output and valve control double, avoiding saturation and overstretch |
| Input configuration | 1 road measurement input (gift input) + 1 outsider input (4–20mA); measurement and external margin operation |
| Input type | 4–20mA, 0–20mA, 1–5V, 0–10V, mV Electrical resistance. 0–400Ω, RTD Pt100 / Cu50, thermocouple K / E / J / T / N / S / B |
| Measurement accuracy | ±0.2%FS (direct signal); RTD ±0.3%FS; thermocouple ±0.3%FS (including cold junction compensation error ±1℃) |
| Sample cycle | 100ms (0.1s); 16 bit A/D conversion, measured digital filter strength 0–15 level available |
| PID parameters | Scale band P 0.1–9999.9%, score time I 1–9999s, calibration time D 0–9999s; calibration line, fraction limit, antisaturation, output change rate limits can be set |
| Control cycle | 0.1–100s is available, matching the travel time of the server Actuator; the server default calculation of the output pulse by valve feedback position |
| Servo output | Inverting / Inverting dual relay output (AC 220V / 1A retardation) or solid state relay output; output with minimum pulse width 0.1s, with dead zone 0.5–5.0% inhibiting frequent movements |
| Valve feedback | Supports 1k–10kΩ or 4–20mA valve feedback; display accuracy ±0.5%FS; automatically cut to time control when feedback breaks Alarm |
| Auto-tuning | Relay feedback method (AT) auto-tuning, which automatically extracts critical oscillation cycles and critical gain and gives PID recommended value; supported manual fixation and parameter copying |
| Manual / automatic changeover | Manual/automatic two-way no-disturbing switch; manual increase or decrease valve level, toggle instant output to maintain current valve level, without impacting process |
| Display unit | Two rows 4 bit LED digital tube (upline measurement PV, downline set SV, toggle display output MV); double light column indicator output and valve level |
| Function Alarm | 2–4 group alarm configurable cap, floor, high and low limits, deviation, block, over range; relay capacity 250VAC/2A |
| Transmitter output | Optional 1 road 4–20mA transmitter output (following measurements or output values) for recorders or DCS collection |
| Communication interface | RS485 (Modbus RTU from station); optional Ethernet; remote setting SV, reading and writing PID parameter and state surveillance support |
| Power supply | AC 85–265V (50/60Hz), power ≤5VA; optional DC 24V power supply |
| Enclosure and protection | Disk assembly 96×96mm, front plate protection IP65, back end IP20; extraction connection end |
| Panel cutout dimensions | 92 × 92mm (wide × high), insertion depth ≤100mm |
| Instrument weight | 0.5kg |
| Applicable standards | JB/T 8214 (industrial process control regulator)/ GB/T 17626 (EMC)/ GB/T 34037 / Reference JJG 617 (digital temperature indicator regulator) |
| Typical applications | Electric Control valve Control of steam, heat, cooling water flow; servo valve adjustment for heat processors, ovens, kilns; closed loops requiring valve feedback, such as heat exchange stations, boiler packs, air conditioners, etc. |
| Product features | Servo output makes a closed loop with valve feedback, which is immediately identifiable when the valve card is thick or the feedback is out; dead zone Adjustable, which is reduced by Actuator, which is a frequent micromovement, which extends the useful life; Auto-tuning, which is based on the physical characteristics of the object and does not have to be based on experience; automatic hand-to-hand undisturbed switch, which is delivered without impact |
Product selection
VISCON-PID-100| Code | Input type |
|---|---|
| I1 | 4~20mA |
| I2 | 0~10V / 1~5V |
| I3 | RTD Pt100 / Cu50 |
| I4 | Thermocouple K/E/J/T |
| I5 | Almighty input (total signal, Standard) |
| Code | Measuring span |
|---|---|
| A1 | -200~+600℃ |
| A2 | 0~+1300℃ |
| A3 | -0.1–0–60MPa (with Transmitter) |
| A4 | 0–9999 General Engineering Unit |
| A5 | Special Range (Specify when ordering) |
| Code | Servo output type |
|---|---|
| O1 | Relay reverses (AC 220V/1A, Standard) |
| O2 | Solid state relays are inverted (no contact, long life) |
| O3 | 4–20mA simulation (with server amplifiers) |
| O4 | Triple-server power drive (order) |
| Code | Valve feedback |
|---|---|
| F1 | 1k–10kΩ (Standard) |
| F2 | 4–20mA valve feedback |
| F3 | No feedback (scheduled control) |
| Code | Control Mode |
|---|---|
| C1 | One turn PID (Standard) |
| C2 | PID + external margin control |
| C3 | PID + string control |
| C4 | Process segment control (≤30, heating/preservation/removation) |
| Code | Display configuration |
|---|---|
| D1 | Double row 4 LED (PV + SV) |
| D2 | Double row LED + Double-light column (output / valve) |
| D3 | LED + 5 inch colour screen curve Display |
| Code | Communication and retransmission |
|---|---|
| T1 | RS485(Modbus RTU) |
| T2 | RS485 + 1 4–20mA Transmitter output |
| T3 | RS485 + Ethernet |
| Code | Alarms and protection |
|---|---|
| P1 | Group 2 Alarm |
| P2 | Group 4 Alarm |
| P3 | Group 4 alarm + Disruption / Super Range / Valve Overtime Protection |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us