Smart PID controllerClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-PID-150
Smart PID controller
Smart PID regulator, Smart PID regulator
01
Classification: Smart PID regulator
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-PID-150 |
|---|---|
| Product function | General-type single circuit PID regulator to receive measured signals such as temperature, pressure, flow, level, output 4–20mA current, time ratio (PWM) or bit style (ON/OFF) to achieve steady control of temperature and pressure by PID algorithm, driver, solid-state relay, contact or Variable frequency drive |
| Input configuration | 1 Librity Measurement Input; optional 1 External (4–20mA) or 1 Remotely Set Switches |
| Input type | RTD Pt100 / Pt1000 / Cu50 / Cu100; thermocouple K / E / J / T / N / S / R / B; direct current 4–20mA / 0–20mA; direct current voltage 1–5V / 0–10V / ±100mV; electrical resistance 0–400Ω |
| Measurement accuracy | ±0.2%FS (Darling signal); RTD ±0.2%FS (Pt100 Koda. ±0.1℃); thermocouple ±0.2%FS,Inline cold junction compensation (Errores) ±1℃); sampling cycle 100ms, 16 bits A/D |
| PID algorithm | Standard position PID, scale band P 0.1–9999.9%, score time I 1–9999s, calibration time D 0–9999s; calibration line, fraction separation, anti-saturation, output limit and change rate limits |
| Auto-tuning | AT auto-tuning, automatically extract object critical cycles and critical gains and write PID parameters; support the consolidation proposal for second-order objects and pure lag objects; restore plant parameters with one key |
| Control Output | 1 4–20mA (load ≤500Ω); 2 time ratio output (cycle 1–120s available, drive solid-state relays or contacts); 3 bits ON/OFF (band hysteresis 0–100%FS) |
| Dual output | Optional heat/cool dual output (cold hot zone PID, dead zone 0–10% available) for both-direction-controlled conditions such as extruders, retrofitters, high-temperature test boxes, etc. |
| Manual / automatic changeover | Manual/Autonomously Undisturbed Switch; Manually set the output percentage directly; Toggle instantaneous output maintained without impact |
| Display unit | Double Platoon 4 bits LED Digital tube (top row) PV Down row. SV, switchable display MV); three colour instructions (green = normal, orange = Alarm Red = Super Range); Optional Double Plumb |
| Function Alarm | 2–4 group alarm configurable ceiling, floor, high and low limits, deviation, block, over range, sensor short circuit; relay capacity 250VAC/2A |
| Transmitter output | Optional 1 road 4–20mA transmitter output (follow PV or MV) for recorders, DCS collection |
| Communication interface | RS485 (Modbus RTU From Station) standard, optional Ethernet; supporting uplink remote settings SV Read and write PID Parameters, Reading Alarm Status |
| Power supply | AC 85–265V (50/60Hz), power ≤5VA; optional DC 24V power supply |
| Enclosure and protection | Disk 96×96mm (optional 72×72mm / 48×96mm vertical); front plate protection IP65, backend IP20 |
| Panel cutout dimensions | 92 × 92mm (96×96); 68 × 68mm (72×72); 45 × 92mm (48×96 vertical) |
| Instrument weight | About 0.4kg (96×96) |
| Applicable standards | JB/T 8214 (industrial process control regulator) / GB/T 17626 (EMC) / Reference JJG 617 (digital temperature indicator regulator Verification regulation) |
| Typical applications | Electrical stoves, ovens, drying equipment, retrofitting cartridges, extruders, heat flow channels, test boxes, Temperature bath, reaction pack temperature control; steam exchangers and single circuits for temperature or pressure of hot water systems |
| Product features | All-capable input, one table covering all Typical sensors, with only one spare parts available on site; three output models can be specified at the selection, and field switching parameters can be adapted to different implementers; Auto-tuning gives parameters by object characteristics to reduce the test; heat/cooling Dual output Optional, two-way temperature control is not in conflict |
Product selection
VISCON-PID-150| Code | Input type |
|---|---|
| I1 | RTD Pt100 / Cu50 |
| I2 | Thermocouple K/E/J/T |
| I3 | Thermocouple S/R/B (precious metals) |
| I4 | 4~20mA / 1~5V |
| I5 | Almighty input (total signal, Standard) |
| Code | Measuring span |
|---|---|
| A1 | -200~+600℃ |
| A2 | 0~+1300℃ |
| A3 | 0~+1800℃ |
| A4 | -0.1–0–60MPa (with Transmitter) |
| A5 | 0–9999 General Engineering Unit |
| A6 | Special Range (Specify when ordering) |
| Code | Control Output |
|---|---|
| O1 | 4–20mA current output (≤500Ω) |
| O2 | Time ratio output (PWM, cycle 1–120s) |
| O3 | Bits ON/OFF (with Hysteresis) |
| O4 | Heating / cooling dual output (cold hot partition PID) |
| O5 | Controlled Silicon Trigger Output (over zero / migration, order) |
| Code | Number of outputs |
|---|---|
| S1 | One-way output |
| S2 | Two-way output (master + Alarm / auxiliary) |
| S3 | Two-way output + 1 |
| Code | Display configuration |
|---|---|
| D1 | Double row 4 LED (PV + SV) |
| D2 | Two rows LED + Double-light column (PV / MV) |
| D3 | LED + Chinese menu (parameter name character Display) |
| Code | Overall dimensions |
|---|---|
| B1 | 96×96mm (Standard) |
| B2 | 72×72mm |
| B3 | 48×96mm vertical |
| B4 | 96×48mm wire |
| Code | Communication and retransmission |
|---|---|
| T1 | RS485(Modbus RTU) |
| T2 | RS485 + 1 4–20mA transmission |
| T3 | RS485 + Ethernet |
| Code | Alarms and protection |
|---|---|
| P1 | Group 2 Alarm |
| P2 | Group 4 Alarm |
| P3 | Group 4 alarm + / Short circuit / Super Range Protect |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us