Monochrome Paperless RecorderClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-REC-150
Monochrome Paperless Recorder
Monochrome Paperless Recorder, Monochrome Paperless Recorder
01
Classification: Monochrome Paperless Recorder
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-REC-150 |
|---|---|
| Product function | Collect and record process signals such as temperature, pressure, flow, Level with single-colour liquid crystal Display real-time trends and numerical values for long-term preservation; lower relative colour screen type costs and higher contrasts under strong light, suitable for routine recording locations where trends are only visible and colour is not sought |
| Display type | 5.6 inch FSTN monochrome crystal, 320×240 dots, blue or black optional; one screen display 4 trend curve + numeric value, curves distinguishing channels by line type and mark (real lines, dash lines, point lines) |
| Display views | Real-time trends, numbers Display, bar charts, historical curve echoes, Alarm list, channel Configuration 6 images, key switching, Chinese character tips |
| Input channels | Standard 4 Channels, optional 8 / 12 / 16 Channels; separation of passages, isolation voltage 500VAC |
| Input type | Direct current 4–20mA / 0–20mA, direct current 1–5V / 0–10V, resistance 0–400Ω, RTD Pt100 / Cu50 / Cu100, thermocouple K / E / J / T / N, frequency 0–10kHz, switch size |
| Measurement accuracy | Direct current voltage ±0.2%FS; RTD ±0.2%FS; thermocouple ±0.2%FS, incorporated cold junction compensation (in error ±1℃); 12 bit A/D conversion |
| Sample cycle | 1s (All-channel sync); optional 0.5s |
| Recording interval | 1s–60min is available; single machine 4 channel 60s can be recorded at intervals of approximately 16 |
| Storage Configuration | Inline 4GB Flash (standard) + SD carat (≤32GB); no loss of power outage data, automatic renewal once power is restored, automatic tags at breaktime |
| Display readings | Display bit sign per channel (Chinese 6), measured value, unit, alarm state; trend area can have time axis span 1min–24h |
| Function Alarm | 2 alarm (ceiling, floor) per channel, totalling 32; alarm timed 0–999s available; optional 4 road or 8 road relay output (250VAC/2A) |
| Transmitter output | Optional 4 4–20mA Transmitter output measurements for either channel |
| Communication interface | RS485 (Modbus RTU from station) Standard; Optional Ethernet; uplink software supports remote viewing, data downloads and curve loops |
| Data Export | SD card or USB interface export CSV file that can open the generated report directly with Excel; export data with timetamps and channel bits |
| Power supply | AC 85–265V (50/60Hz) or DC 24V; power ≤12VA |
| Enclosure and protection | Disk 160×80mm transverse structure, front plate protection IP65, back end IP20 |
| Panel cutout dimensions | 152 × 76mm (wide × high), insertion depth ≤170mm |
| Instrument weight | 1.0kg |
| Applicable standards | JB/T 6803 (recorder)/ GB/T 34037 (industrial process measurement recorder)/ GB/T 17626 (EMC)/ Reference JJG 74 (recorder Verification regulation) |
| Typical applications | Breadboxes, drying equipment, incubators, cold- and cold-chain monitoring, water treatment, heat-for-heat stations, etc. |
| Product features | Single-colour screen is better compared to the colour screen in a strong light workshop than in an outdoor cabinet, long-term Display is not colour-biased; costs are lower than the colour screen type Number of channels as required Optional; paperless materials are free and data can be retrieved; Chinese Display does not need to read against labels |
Product selection
VISCON-REC-150| Code | Number of channels |
|---|---|
| C4 | 4 channel (Standard) |
| C8 | 8 channel |
| C12 | 12 channel |
| C16 | 16 channel |
| Code | Input type |
|---|---|
| I1 | Almighty input (electricity/voltage/retardation/ RTD / Thermocouple) |
| I2 | Electricity current voltage input (4–20mA / 0–10V) |
| I3 | Temperature special (RTD / TC) |
| I4 | Frequency with Pulse input |
| Code | Sample cycle |
|---|---|
| S1 | 1s (Standard) |
| S2 | 0.5s |
| Code | Display configuration |
|---|---|
| D1 | 5.6 inch monochromic crystal, blue and white mode (Standard) |
| D2 | 5.6 inch monochrome crystal, black and white mode |
| D3 | Single screen + 4 bar |
| Code | Alarm output |
|---|---|
| A0 | Unrelaying output |
| A4 | 4 path relay (250VAC/2A) |
| A8 | 8 path relay (250VAC/2A) |
| Code | Storage and Export |
|---|---|
| M1 | 4GB inline Flash |
| M2 | 4GB inline + SD carat (Standard) |
| M3 | 4GB + SD calories + USB export |
| Code | Communication interface |
|---|---|
| T1 | RS485(Modbus RTU) |
| T2 | RS485 + Ethernet |
| T3 | RS485 + Ethernet + Wireless module (order) |
| Code | Power supply |
|---|---|
| V1 | AC 220V(85~265V) |
| V2 | DC 24V |