Isolation security fenceClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-SB-100
Isolation security fence
Segregation security fence, Segregation security fence (blastproof)
01
Classification: the security fence
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-SB-100 |
|---|---|
| Product function | Installed in Safe area,string on Hazardous area Intrinsically safe Instrument and Safe area Between control systems, electrical isolation (several circulation and commotion interference) and restriction of inflow Hazardous area The voltage, currents and power, so... Hazardous area You can choose. Standard type (Non-Ex And the whole circuit is still satisfactory. Intrinsically safe Request |
| Explosion protection marking | [Ex ia] II C (associated equipment) 0 Region, 1 Region, 2 Area IIA / IIB / IIC Category explosive gas environment; temperature group T4–T6 Press Ambient temperature and Configuration Identification; subject to Intrinsically safe The instrument will be accounted for before it is put in place. |
| Intrinsic safety parameters | Um 250VAC; Uo 28V, Io 93mA, Po 0.65W; IIC Co 0.083μF, Lo 4.2mH IIB Co 0.65μF, Lo 14mH; on-site connection should ensure that the internal capacity of the cable Hazardous area side cables, senses and receivers does not exceed the limits mentioned above |
| Function Type | Detection end (hazardous area signal in safe area, with electrical distribution to hazardous area instrument), operational end (safe area signal delivery hazardous area driver or locator), two-way (wire current flow, HART can be two-way Communication); three are distinguished by endwire, same hardware is common and no on-site functional change Model |
| Input and Output | Enter 4–20mA (compatible 0–20mA) or 1–5V; output 4–20mA; One input, one output; input, output and power source three end in isolation |
| Transmitter supply capacity | Hazardous area 2 transmitter test end-type can provide 18V / 25mA distribution (short-circuit limit ≤28mA to withstand long-term short-circuit undamaged); HART digital signal transparent transmission, Safe area handheld can normally read and write live meters |
| Transfer Accuracy | ±0.1%FS (20℃); temperature drift ≤0.01%FS/℃; output load capacity 0–550Ω; linear ≤±0.05%FS |
| Response time | ≤10ms (10%–90% step change); HART channel bandwidth ≥2.4kHz Communication is not affected by filtering |
| Isolation rating | Three-end isolation 1500VAC / 1min (input-out-power); common-mode rejection ≥120dB, serial inhibition ratio ≥60dB; effective inhibition of interference Variable frequency drive in the difference between the local grid level |
| Open-circuit detection | <3.6mA) When entering a breakline, the output selects to drift down to ≤3.6mA or up to ≥21mA for DCS to determine the direction of the failure and trigger the corresponding lock to avoid miscalculating the breakline as low |
| Power | DC 20–35V (typical 24V), power ≤1.2W; power Reverse polarity protection; Optional redundant power source (two circuits combined with diodes, no electricity loss of any route affecting work) |
| Structure | 35mm DIN rail installation, outer 12.5mm × 110mm × depth 115mm; flame retardation PC/ABS outer shell (UL94 V-0) capable of dense parallel installation |
| Connect | Plugged screw end, applying line 0.5–2.5mm2; Intrinsically safe with blue end and markers, distinguished from non Intrinsically safe (grey) in colour and position |
| Protection and environment | IP20; working temperature -20–+60℃; humidity ≤95%RH non-condensing; to be installed in safe area, and intrinsically safe side guide separated from non- intrinsically safe guide (space ≥50mm), Intrinsically safe circuit leads suitable for blue |
| Instrument weight | 150g |
| Applicable standards | GB 3836.1 (explosive environment general requirements)/ GB 3836.4 (intrinsically safe type ia)/ GB/T 18271 (process measurement and control device performance assessment)/ GB/T 17626 (EMC) |
| Typical applications | It's petrochemical and chemical. Intrinsically safe Check back roads, fuel tanks and canisters. Level Measurement, gas and gas site measurement, solvent environment in pharmaceutical and paint workshops, on-site instrumentation side of the dust-gas co-exist site; also for normal signal loops that require electrical isolation but have no blast-proof requirements |
| Product features | One input, one output Basis model You can cover most of them. intrinsically safe circuit Spare parts model Single; test end, operating end and two-way depending on the endwire, no replacement of the site function; tri-end segregation 1500VAC, cutting off circulation and comprehensible interference; HART Transparent. Safe area Handheld still available. Configuration (a) On-site smart instrument; Intrinsically safe Side blue end plus signpoints. Connections are easy to connect with during acceptance. |
Product selection
VISCON-SB-100| Code | Function Type |
|---|---|
| F1 | End of detection (with electrical distribution, signal entry Safe area) |
| F2 | Operating end (signal delivery Hazardous area) |
| F3 | Two-way (HART 2 Communication, Standard) |
| F4 | One input, two outputs |
| Code | Input type |
|---|---|
| I1 | 4~20mA |
| I2 | 0~20mA / 0~10mA |
| I3 | 1~5V / 0~10V |
| I4 | Thermocouple TC mV |
| I5 | RTD RTD (0–400Ω) |
| Code | Output Type |
|---|---|
| O1 | 4–20mA (Standard) |
| O2 | 0~20mA |
| O3 | 1~5V |
| O4 | Relay contacts (switch output type) |
| Code | Transmitter supply capacity |
|---|---|
| P0 | No electricity distribution (operating end Typical) |
| P1 | 18V / 25mA (Standard) |
| P2 | 24V / 30mA |
| Code | Open-circuit failure direction |
|---|---|
| B1 | ≤3.6mA |
| B2 | ≥21mA |
| B3 | Jump Optional (Standard) |
| Code | Power supply configuration |
|---|---|
| V1 | DC 24V |
| V2 | DC 20–35V broad input (Standard) |
| V3 | Light + redundant power source |
| Code | Explosion protection marking |
|---|---|
| E1 | [Ex ia] II C (Standard) |
| E2 | [Ex ia] II B |
| E3 | [Ex ib] II C |
| Code | Terminals and accessories |
|---|---|
| A1 | Standard screwdriver |
| A2 | Blue intrinsically safe end + identifier (Standard) |
| A3 | A2 + transparent dust cover |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us