Isolation security fenceClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

VISCON-SB-100

Isolation security fence

Segregation security fence, Segregation security fence (blastproof)

01

Classification: the security fence

02

Check configuration based on field work

Return to quarantine security fence classification

TECHNICAL SPECIFICATIONS

Technical specifications

VISCON-SB-100

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelVISCON-SB-100
Product functionInstalled in Safe area,string on Hazardous area Intrinsically safe Instrument and Safe area Between control systems, electrical isolation (several circulation and commotion interference) and restriction of inflow Hazardous area The voltage, currents and power, so... Hazardous area You can choose. Standard type (Non-Ex And the whole circuit is still satisfactory. Intrinsically safe Request
Explosion protection marking[Ex ia] II C (associated equipment) 0 Region, 1 Region, 2 Area IIA / IIB / IIC Category explosive gas environment; temperature group T4–T6 Press Ambient temperature and Configuration Identification; subject to Intrinsically safe The instrument will be accounted for before it is put in place.
Intrinsic safety parametersUm 250VAC; Uo 28V, Io 93mA, Po 0.65W; IIC Co 0.083μF, Lo 4.2mH IIB Co 0.65μF, Lo 14mH; on-site connection should ensure that the internal capacity of the cable Hazardous area side cables, senses and receivers does not exceed the limits mentioned above
Function TypeDetection end (hazardous area signal in safe area, with electrical distribution to hazardous area instrument), operational end (safe area signal delivery hazardous area driver or locator), two-way (wire current flow, HART can be two-way Communication); three are distinguished by endwire, same hardware is common and no on-site functional change Model
Input and OutputEnter 4–20mA (compatible 0–20mA) or 1–5V; output 4–20mA; One input, one output; input, output and power source three end in isolation
Transmitter supply capacityHazardous area 2 transmitter test end-type can provide 18V / 25mA distribution (short-circuit limit ≤28mA to withstand long-term short-circuit undamaged); HART digital signal transparent transmission, Safe area handheld can normally read and write live meters
Transfer Accuracy±0.1%FS (20℃); temperature drift ≤0.01%FS/℃; output load capacity 0–550Ω; linear ≤±0.05%FS
Response time≤10ms (10%–90% step change); HART channel bandwidth ≥2.4kHz Communication is not affected by filtering
Isolation ratingThree-end isolation 1500VAC / 1min (input-out-power); common-mode rejection ≥120dB, serial inhibition ratio ≥60dB; effective inhibition of interference Variable frequency drive in the difference between the local grid level
Open-circuit detection<3.6mA) When entering a breakline, the output selects to drift down to ≤3.6mA or up to ≥21mA for DCS to determine the direction of the failure and trigger the corresponding lock to avoid miscalculating the breakline as low
PowerDC 20–35V (typical 24V), power ≤1.2W; power Reverse polarity protection; Optional redundant power source (two circuits combined with diodes, no electricity loss of any route affecting work)
Structure35mm DIN rail installation, outer 12.5mm × 110mm × depth 115mm; flame retardation PC/ABS outer shell (UL94 V-0) capable of dense parallel installation
ConnectPlugged screw end, applying line 0.5–2.5mm2; Intrinsically safe with blue end and markers, distinguished from non Intrinsically safe (grey) in colour and position
Protection and environmentIP20; working temperature -20–+60℃; humidity ≤95%RH non-condensing; to be installed in safe area, and intrinsically safe side guide separated from non- intrinsically safe guide (space ≥50mm), Intrinsically safe circuit leads suitable for blue
Instrument weight150g
Applicable standardsGB 3836.1 (explosive environment general requirements)/ GB 3836.4 (intrinsically safe type ia)/ GB/T 18271 (process measurement and control device performance assessment)/ GB/T 17626 (EMC)
Typical applicationsIt's petrochemical and chemical. Intrinsically safe Check back roads, fuel tanks and canisters. Level Measurement, gas and gas site measurement, solvent environment in pharmaceutical and paint workshops, on-site instrumentation side of the dust-gas co-exist site; also for normal signal loops that require electrical isolation but have no blast-proof requirements
Product featuresOne input, one output Basis model You can cover most of them. intrinsically safe circuit Spare parts model Single; test end, operating end and two-way depending on the endwire, no replacement of the site function; tri-end segregation 1500VAC, cutting off circulation and comprehensible interference; HART Transparent. Safe area Handheld still available. Configuration (a) On-site smart instrument; Intrinsically safe Side blue end plus signpoints. Connections are easy to connect with during acceptance.

Product selection

VISCON-SB-100
Function Type
CodeFunction Type
F1End of detection (with electrical distribution, signal entry Safe area)
F2Operating end (signal delivery Hazardous area)
F3Two-way (HART 2 Communication, Standard)
F4One input, two outputs
Input type
CodeInput type
I14~20mA
I20~20mA / 0~10mA
I31~5V / 0~10V
I4Thermocouple TC mV
I5RTD RTD (0–400Ω)
Output Type
CodeOutput Type
O14–20mA (Standard)
O20~20mA
O31~5V
O4Relay contacts (switch output type)
Transmitter supply capacity
CodeTransmitter supply capacity
P0No electricity distribution (operating end Typical)
P118V / 25mA (Standard)
P224V / 30mA
Open-circuit failure direction
CodeOpen-circuit failure direction
B1≤3.6mA
B2≥21mA
B3Jump Optional (Standard)
Power supply configuration
CodePower supply configuration
V1DC 24V
V2DC 20–35V broad input (Standard)
V3Light + redundant power source
Explosion protection marking
CodeExplosion protection marking
E1[Ex ia] II C (Standard)
E2[Ex ia] II B
E3[Ex ib] II C
Terminals and accessories
CodeTerminals and accessories
A1Standard screwdriver
A2Blue intrinsically safe end + identifier (Standard)
A3A2 + transparent dust cover

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
VISCON-SB-100 Galvanically Isolated Intrinsic Safety Barrier